1
II
Maximum range
Internal fractional value
Display division value
Nonlinear error
Maximum counting range
Display device
3 kg 6 kg 15kg 30kg 30lb
60lb 3/6kg 6/15kg 15/30lb 30/60lb
Up to 100,000
Range 1000 ~ 20000
<0.008% FS (display only)
0 ~ 60000PCS
Operating temperature
Use relative humidity
0 ~ 40℃
15% ~ 85%RH( No condensing )
Monitor
Capacity indicator
Unit of weight
Status Indicator
Decimal symbol
Operation buttons
Power supply
Interface
6-digit LCD, 14 indicators
4
5 of them, g/kg/lb/oz/pcs
6 of them are ZERO/STABLE/NET/S1/S2/S3
You can choose "." or ","
[REZERO]/[UNIT/ ← ]/[TARE/ ↑ ]/[ON/OFF]
1. 4 R20P SIZE D 1.5V dry batteries
2. External AC adapter DC 5~12V/0.5A
1 RS-232 interface (data 600 ~ 57600 bit/s
baud, 8bit Data, 1bit Stop, No parity bit)/1
USB communication interface
1.1 Product specications
1000
3000 4000 5000 6000 7500
10000 12500 20000
1250 1500 2000 2500
Please avoid placing the product in the following locations:
If the temperature is too high or too low, direct sunlight, wet place;
At the shared power supply, excessive vibration, dust, and moisture.
Do not press the button too hard, please touch the button.
Do not suddenly bump into the machine to avoid damaging the load cell.
Do not press the center of gravity on the weighing platform to avoid damage to the load cell.
To clean the weighing pan and keyboard, use a dry cloth and wipe with a detergent. Do not use
thinner or other volatile solvents.
In order to ensure the normal use of the scale, before starting the operation every day, adjust the
level and lock the foot nut, and place a known weight of the item on the weighing platform to check
the weighing of the scale.
Do not place the instrument on an unstable or inclined surface to avoid dropping.
Use standard thermal paper to store thermal paper under direct sunlight, high temperatures, dust, or
moisture.
When the mechanical equipment is moved to a higher temperature in a place with a lower
temperature (such as a refrigerating room), because the temperature difference is large, the power
supply cannot be turned on immediately to prevent the condensation of the water vapor and cause
damage to the machine.
Keep one socket and one machine, avoiding high voltage or equipment that may cause power
interference.
Thermal print head failure is not covered by the warranty. Please use and maintain the equipment
properly according to the instructions or service personnel's recommendations.
Do not use the long-distance line of the power Plug of the scale. Be sure to keep it in the AC
socket. Keep the hand dry when pulling the Plug. Excessive bending and pulling will damage the
power cord and cause re or electric shock.
Please follow the prompts to extend the life.
*NOTICE
PRECAUTIONS
If you have any questions,
please contact your local
dealer or visit our website:
www.dbscale.com.cn
Thank you.
1. CONVENTIONAL
1.1 Product specications