Installation Manual for CU220 DP
DELTA RC AS Page 8 of 12
Document: 02974
3. TECHNICAL DATA
This equipment is designed for failsafe operation, meeting the stringent requirements for safe operation.
It is in accordance to EU’s demands to CE-label the equipment.
3.1 GENERAL SPECIFICATION
* Temperature Range: Operational and storage: -25 to +65º C.
* Shock Resistance: 2 m free-fall on concrete floor.
3.2 CONTROL UNIT,CU212-1S
* Power Supply: 11 to 35 VDC. Voltage above 35VDC shuts down the receiver.
* Power Consumption: Standby: 22 mA.
* Outputs: Semiconductor output. Temperature and overload protected. Output
voltage is equal to power input; 12/24 VDC. Each output, max 3,5A
total load, 5A. Fused inside by 5A slow blow Auto fuse.
* Deadman output. Active when deadman switch is operated.
* Warning light output, active during operation of the deadman
* Beeper warning output
* STOP output. When control unit is powered, this output is active,
output is12/24V. When STOP is detected, this output is switched off, 0V.
* Optional inputs *The CU212-1S is programmed to operate with a none failsafe handswitch.
* Deadman override, low input activates the override function
* External STOP, low input actives STOP of deadman function.
* Connections: Screw terminal on PCB connector.
* Indicators: Green light diode that indicates power on.
Yellow light diode that indicates active deadman.
* Housing: ABS polycarbonate, class IP52.
* Dimensions: L:160 mm, W: 80 mm, D: 60 mm.
* Weight: 0.7 kg