Digital Loggers Web Power Switch 7 Bedienungsanleitung

USER’S GUIDE
Web Power Switch 7

Web Power Switch 7 digital-loggers.com
2
Product Features
Congratulations on selecting the DLI Web Power Switch, a
surge-suppressed, AC power switch with automatic reboot and
programmable power control. Features include:
Simple Web Interface
The internal web server is accessible from any standard browser.
Simply enter an IP address. The controller may be configured and
controlled via the web.
Auto-Ping Reboot
This automatic feature monitors a remote IP address. If a server,
router, or other peripheral goes down, the switch will automatically
reboot it, without user intervention. Up to 8 devices can be
monitored individually.
8 Switched Outlets + 2 Unswitched Outlets
Eight individually switched controlled circuits are provided with
single outlets. Outlets are spaced for large adapters and plugs.
Two unswitched outlets are provided for “always on” devices.
LCD Display
A 2x16 LCD displays status for each outlet. Custom messages
can be displayed using a simple scripting language.
Password Security
Multi-user password security is provided to limit access to certain
circuits. The administrator selects which outlets each user can
control.
Sequenced “On Timer”
A programmable delay timer allows outlets to be switched on in
sequence, rather than simultaneously. Most devices draw more
power when they are initially switched on. Using this timer, more

Web Power Switch 7 3
equipment can be attached to a single circuit without overloading.
Programmable scripts can also be used to create customized
power-up and power-down sequences with variable timing.
MOV Surge Suppression
A 3600W metal oxide varistor clamps power surges and spikes,
protecting all attached devices.
Scripting Language, Syslog, and Utilities
A scripting language can be used to create custom control and
reboot sequences, schedule periodic reboots, customize the LCD,
and control serial devices. Both internal and external system logs
are provided. Windows utilities send status notifications, warnings,
and power bills via email.
New Features
New features include a larger keypad, extended real-time clock
battery life, scheduling function, removable power cord, Wake on
Lan (WOL) support, NTP sync, Apple iOS and Android support.
Learn more about new features here.
Field Upgradeable Firmware
Firmware is field upgradeable via Ethernet using the web or a
command line utility on AC powered products only.
Standard Package Contents
• Web Power Switch 7
• Power Cord
• Registration Card
• Manual
Please contact the shipping carrier immediately if your package
appears opened or damaged in transit. Call (408) 330-5599 for
tech support, service, and hardware upgrades.

Web Power Switch 7 digital-loggers.com
4
Important Factory Defaults
DEFAULT IP ADDRESS
The factory default is 192.168.0.100
DEFAULT ADMINISTRATOR LOGIN
User name: admin (lower case)
Password: 1234
To reset the IP address and admin login to factory defaults, gently
press the reset-to-defaults button to the left of the LCD.
Note: Reset-to-defaults sets the admin login and IP address, but
it doesn’t affect outlet names, links, and stored scripts. Auto-Ping
and auto-start of custom scripts are disabled.
Quick Setup
Use these shortcuts if you are an experienced installer. If this is
your first time, please skim the entire manual first.
1. Remove the switch from its shipping carton. Save the
carton and packing for future hardware upgrade.
2. Attach the power cord to a protected power source with a
capacity of at least 15 amperes.
3. Attach the cable from the controller to a port on your

Web Power Switch 7 5
LAN. Switch power on. If you are connected to a switch,
you may need to cycle power to the switch to establish a
connection.
4. Ping the default address: 192.168.0.100 to confirm a
network connection is established. If you don’t receive a
response, see the IP Setup section below.
5. Log in to the power controller using the default user name
admin and the password 1234
“admin” must be entered in lower case.
6. Click on the Settings link to reach the configuration page.
7. Select the safest power-loss configuration for your
installation: (all OFF, all ON, or sequential ON)
8. Configure the power switch as described below. After
each change, click Submit and wait for the page to refresh
before continuing.
Tips:
• A three-bulb electrical safety-tester is handy for configuring
the controller before attaching your equipment.
• Please register your product for better support and free
firmware updates
IP Setup
If your network settings won’t access the default IP, use a direct
cable connection (temporarily bypass any switch or router)
and follow these steps to add a compatible static IP such as
192.168.0.50 Before adding an IP, close programs and browsers.
After the link is established, you can revert to DHCP if desired or
use a combination of DHCP and static IPs.

Web Power Switch 7 www.digital-loggers.com
6
Windows Step 1
In Windows, the first step is locating the network adapter TCP/IP
properties. The procedure differs for each Windows version:
Windows XP, 2000, 2003: Open Start / Control Panel / Network
Connections. If you’re using “classic view”, it’s Start / Settings /
Control Panel /Network Connections. Right-click on Local Area
Network Connection and select Properties. Proceed to step 2.
Windows Vista: Open Start, right click on Network, then on
Properties. Double click Network and Sharing Center, click
Manage Newtork Connections. A Network Connections window
appears. Right click on the network connection to the switch, ie.
Local Area Network. Proceed to step 2.
Windows 7: Use the default Category View. Open the Start orb,
click on Control Panel. Click View Network Status and Tasks,
then Change Adapter Settings. Proceed to step 2
Windows 8: Mouse or swipe to the bottom right corner and select
Settings. Select Control Panel. Select Network and Sharing
Center. Change Adapter Settings. Right click on your connected
network and select Properties. Proceed to step 2
Windows 10: Select Start -> Settings -> Network and Internet
-> Ethernet. Then click “Change Adapter Options” to set IPs.
Windows Step 2
The second step is adding an IP such as 192.168.0.50. If you are
using DHCP, it’s easiest to temporarily disable it while configuring
the switch.
Select Internet
Protocall TCP/IP
V4 Properties and
click Properties.
Enter a compatible
static IP such
as this:

Web Power Switch 7 7
Click Apply and close windows. Ping the power switch to confirm
the connection. Point your browser at 192.168.0.100 and log in.
Find detailed instructions at digital-loggers.com/ip_setup.html
Max OS X
Turn AirPort off temporarily. Click the Apple logo, then System
Preferences, then Network. Select Built-In Ethernet and then
Configure. Under the TCP/IP tab, select Manually and enter an
IP address sucha s 192.168.0.50 as shown:
Make changes shown.P oint your browser at 192.168.0.100 and
log in. Find more detailed mac instructions at digital-loggers.com/
mac_ip_setup.pdf
Keypad Setup
Most network settings can also be changed from the keypad.
Learn how at www.digital-loggers.com/keypad.html
Basic Operation
After power-up, the controller performs a sequence of self-tests to
ensure reliability. Network settings on the Settings page are used:

Web Power Switch 7 digital-loggers.com
8
The IP address of the controller needs to match the “class C”
of your system. In other words, the first three bytes (192.168.0)
must be the same as the IP address on your computer in order to
access the controller. Using a Ping utility is a good way to confirm
you have a valid network configuration.
Once you have a connection, the controller may be operated via a
web browser. To access the controller, enter the IP address in the
URL field of your web browser. The default is http://192.168.0.100.
Home (Outlet Control) Page
To access the home page, first enter the IP address in web
browser URL field, then log in. User admin has access to all

Web Power Switch 7 9
features. Other users have limited access to outlets as assigned
by the administrator. When configuring the power controller for the
first time, use the default admin username and 1234 password.
The home page contains 13 external hyperlinks. The first nine are
fixed internal links: The four links in the lower left corner of the
screen are user-programmable.
Outlet Control
Clicking “Outlet Control” links to the home page used for
manually switching outlets on and off. Access to specific outlets is
determined by your login. Admin has access to everything.
Setup
The setup page lets you select outlet names, program web links,
startup delays, and the power loss recovery mode. You can also
change login credentials on this page.
Scripting
A scripting language using BASIC commands lets you
customize the power controller. Scripts may be started manually,
automatically on power-up, by external http commands, or by
Auto-Ping events. Find a full list of commands and example scripts
at: digital-loggers.com/scripting.html
Auto-Ping
The Auto-Ping link lets you set parameters to automatically reboot
attached equipment. First specify an IP address to ping. Next
adjust the timing settings and use the checkboxes to link the IP to
specific circuits. For example, if a router is unreachable, you may
choose to automatically reboot both a router and a switch on two
different circuits. Learn more: digital-loggers.com/auto-ping.html.
System Log
The power controller keeps a log of system events including logins
(successful and attempted), outlet switching, power interruptions,
and Auto-Ping events. Recent events are stored in the log and

Web Power Switch 7 digital-loggers.com
10
accessible from the System Log page. Multiple controllers
can export logs to a single external SYSLOG server. For more
information on syslog: digital-loggers.com/syslog.html
Logout
The controller will automatically log-out when your browser
session is closed. Click this link to log-out in advance.
Help
The Help link displays the latest online manual. Since features
are subject to change without notice, this manual may not be an
exact match for earlier controllers and earlier firmware versions.
Find the firmware revision history here.
Programmable Web Links
Four additional user-defined web links are provided on the outlet
control page. Factory defaults are Manual, FAQ, etc. You may
change the name and destination URL for these links on the
Settings page. These links are convenient for connecting to
other power controllers or to remote sites.
Switching Outlets On and O
The outlet control page lets you control any outlet (except the
always-on pair). A master setting also allows users (with security
access) to switch all outlets on or off.
To switch an outlet on or off, simply click to the right of the outlet
name or number. Switching is immediate.
Use the keypad for local control: Select an outlet using the
arrow keys, then press on, off, or cycle. Press ON or OFF for
5 seconds to lock or unlock an outlet. Locking prevents web
access. Admin may disable the keypad on the setup page.
Andere Handbücher für Web Power Switch 7
1
Inhaltsverzeichnis
Andere Digital Loggers Schalten Handbücher

Digital Loggers
Digital Loggers Web Power Switch 6 Bedienungsanleitung

Digital Loggers
Digital Loggers LPC-2 Bedienungsanleitung

Digital Loggers
Digital Loggers Web Power Switch III Bedienungsanleitung

Digital Loggers
Digital Loggers SS20 Bedienungsanleitung

Digital Loggers
Digital Loggers 20-Port Serial Switch Bedienungsanleitung

Digital Loggers
Digital Loggers Web Power Switch 4 Bedienungsanleitung

Digital Loggers
Digital Loggers Automatic Fail-Over Switch Bedienungsanleitung

Digital Loggers
Digital Loggers 32-Port DC Bedienungsanleitung