Installation instructions
Before choosing an air conditioner, we recommend carrying out a cooling load calculation according to the standard, or on the
basis of a relevant standard. Forms for cooling load calculation complete with instructions can be obtained from the
manufacturer or wholesaler or on the Internet at www.dimplex.de
Indoor or outdoor units, which are not installed according to instructions, may cause a reduction or loss of warranty in case of
repair!
Choosing the installation location
It is very important to install split devices in suitable locations as it is difficult, and thus expensive, to move them after installation.
If possible, decide on the installation location in agreement with the final customer. The installation site must be suitable for
bearing the weight and the operational vibration of the indoor or outdoor unit on a permanent basis.
Notes on the installation of the indoor unit
The circulating air should flow through the whole of the room to be cooled.
The flow of cold air should not be directed at persons or their place of work.
The condensation formed during cooling must be drained off without impairing functioning. If the condensate can only be led off
upwards or without a downward slope, then the installation of a condensate pump is necessary.
The component may not be installed in rooms subject to high humidity in which the device is in contact with moisture or water.
The device may not be installed in rooms in which oil vapour is emitted or could be emitted.
Notes on the installation of the outdoor unit
The outdoor unit should be installed in a place where it will not become soiled.
When there is a danger of condensate freezing (heating operation when outside temperatures are low), the condensate drain
stubs should be removed and additional insulation be provided for the drainage area. Freezing condensate (e.g. the formation of
ice on the heat exchanger) can impede the fan function of the outdoor unit.
The outdoor unit must be installed in compliance with the regulations regarding the assessment of operational noise in the
neighbourhood. In particular, a suitable distance from bedrooms and similar rooms should be maintained.
The device may not be installed in areas of aggressive air!
Scope of supply
Please check that the delivery is complete and that the devices are undamaged.
The scope of supply includes:
• Split air conditioner consisting of indoor and outdoor unit (2 packaging units in case of complete order),
• Mounting plate for wall mounting of the indoor unit, slotted into it (incl. screws)
• Remote control (incl. 2 batteries),
• Condensate drain plug for draining condensate in the outdoor unit,
• Control line with connection plug routed in the refrigerant pipe,
• Mains connection cable,
• Installation and operating instructions