Dingtek DF702 Merkblatt

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863, 64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 2
CNDingtek Technology Company
IOT Leading Brand
The purpose of
Measurement, Instrumentation, and Sensors Handbook
CNDingtek
is to provide a
reference that is both concise and useful for engineers in
industry, scientists, designers, managers, research
personnel and protocol , as well as many others who
have measurement problems.
We provide to our Customer Protocol,Installation , Operation and
Configuration detailed of devices.
A Smart City Project of CNDingtek Technology Company

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863, 64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 3
Index
1 Overview.......................................................................................................................................4
2 Device Function Descriptions..................................................................................................... 4
3 The main LoRa band introduction..............................................................................................6
4 Device interface definition.......................................................................................................... 6
5 Configure LoRa parameters....................................................................................................8
5.1 Required tools for configuration of LoRa Device................................................................... 8
5.2 Connect TTL to sensor...................................................................................................... 9
5.3 Environment to Configuration of Device.......................................................................11
5.4 Video link......................................................................................................................... 15
6 Configurations of Relevant Parameters of Device............................................................ 15
6.1 Required tools................................................................................................................. 15
6.2 Connect TTL to sensor.................................................................................................... 16
6.3 Use serial software to configure.................................................................................... 18
6.4 Video link......................................................................................................................... 21
7 Upgrade devices...................................................................................................................... 21
7.1 Instructions..................................................................................................................... 21
7.2 Tools................................................................................................................................. 21
7.3 Connect TTL to sensor.................................................................................................... 21
7.4 Upgrade steps.................................................................................................................. 23
7.5 Video link......................................................................................................................... 32
Attachment.................................................................................................................................... 32
1Network server introduction......................................................................................... 32
1.1 Dingtek..................................................................................................................... 33
1.2 TTN........................................................................................................................... 33
1.3 Loriot........................................................................................................................ 35
1.4 Actility...................................................................................................................... 42
Common problem.......................................................................................................................43

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863, 64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 4
1 Overview
In these documents information about of LoRa Module DF702 Trash Bin Sensor are given
with detailed.
The function of device
Hardware interface
How to set LoRa module parameters
Equipment parameters (full height value, upload interval data etc)
Equipment upgrades
For more information if you have any questions, please contact us first.
2 Device Function Descriptions
Note
Device will upload data when its power is activated it can send us data automatically to the
user through LoRa Module.
Main Function of Device
LoRa Module DF702 Sensor can give detailed about the using place for example Trash Bin
its full Detection, fire detection, fall Detection , Full ,Half and Empty Condition of Device and
about the power Detection of Sensor.
Notes: the standard version does not have the fall detection, only the enhanced
version has this function.

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863, 64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 5
Data Time Intervals
For example Test time data every 10 minutes, when a change of state is detected the data
will be upload, the state remains unchanged in next intervals, and no data will be uploaded.
The data will be uploaded periodically like as heartbeat the data interval default 4 hours can
be modified, specific reference to the agreement.
State change means:
From full to not from
Not from to full
Main
Function
Functional
Descriptio
n
Default Alarm
Threshold
Whether the
data will be
reported
immediately
when the
alarm
condition is
reached
Remarks
Full
Check if the
Trash bin is
full
30cm
(Can be
modified)
No
The Device will detect
the Distance between
sensor and garbage if
this Distance is more
Then 30cm no alarm
if less than 30 cm
alarm will be
activated.
Fire
Detect if a
fire has
been
occurred
75℃
(Can be
modified above
75℃
Fire alarm will
be activated )
Yes
Detected temperature
is less than 75℃
above this
Temperature sensor
will activate the
alarm.
Fall
Check
whether the
trash Bin
can fallen
any side
This feature is
available in enhanced
version not in
slandered version.
Battery
Check if the
battery is
about to run
out
20%
(Can be
modified)
No
It will detect the
power of battery
more than 20% no
alarm less than 20%
alarm will be
activated.

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863, 64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 6
For example: Time State Upload data or no
10:10 full Yes (Battery Should be connected)
10:20 full No
10:30 not full Yes
10:40 not full No
10:50 full Yes
3 The Main LoRa Band Introduction
The main LoRa band are used given below CN470, EU868, US915, AU915, AS923.
4 Device Interface Definition
In the given figure, the power interface, module configuration debugging, interface, device
parameter configuration and upgrade interface are introduced respectively with detailed.
In figure 4.1 PCB board is shown and all connecting parts are also shown which part where
will be placed.
4.1 Connection of Hollow Sockets
Power socket: connect the battery
Hollow positions: Configure the LoRa module parameters or debug module the
jumper cap should be placed in a hollow position.
Solid position: The default position the device to transmit data/configure device
parameters such as data upload interval and full height the jumper cap should be
placed at right side a solid position.
Band
The default uplink
frequency
The default downlink
frequency(RXWIN1)
The default
downlink
frequency
(RXWIN2)
CN470
(470-510MHz)
470.3,470.5,470.7,470.9,
471.1,471.3,471.5,471.7,
500.3,500.5,500.7,500.
9
501.1,501.3,501.5,501.
7
505.3
EU868
(863-870MHz)
868.1,868.3,868.5
868.1,868.3,868.5
869.525
US915
(902-928MHz)
902.3,902.5,902.7,902.9,
903.1,903.3,903.5,903.7
923.3,923.9,924.5,925.
1
925.7,926.3,926.9,927.
5
923.3
AU915
(915-928MHz)
915.2,915.4,915.6,915.8
916.0,916.2,916.4,916.6
923.3,923.9,924.5,925.
1
925.7,926.3,926.9,927.
5
923.3
AS923
(915-928MHz)
923.2,923.4
923.2,923.4
923.2

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863, 64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 7
Figure4.1
4.2 Reverse side of picture of PCB board ( open the Screws of PCB Board) as shown in
figure 4.2.
TX
RX
GND
Hollow position
Solid position
Black part of the jumper cap,
the default in this position
This interface can be used to
modify Lora parameters as well
as debug module
This power socket is
used to connect the
Battery
+
-

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863, 64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 8
Figure4.2
5 Configure LoRa parameters
LoRa can be configured according to the relevant parameters such as devaddr, deveui and
nwkskey are helpful in configuration process.
Required tools for configuration of LoRa Device
TTL and its cable
Serial software
LoRa instruction manual
Equipment
TTL and cable for the goods accessories
Please check these two items when you receive package from company as shown in Figure
5.1 and Figure5.2.
GND
TX
RX
This interface is used to
configure device parameters
(data upload interval, full
height value, etc.), device
upgrade, or device
debugging.

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863, 64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 9
Figure5.1
Figure5.2
Serial software:
5.2 Connect TTL to sensor
Device Serial Port connection GND, TX, and RX locations have been marked on the diagram
as shown in Figure5.3.
TTL
TTL
Cable

Beijing Dingtek Technology Corp., Ltd. Tel:86-10-64718863, 64753700
http://www.dingtek.com E-mail: service@dingtek.com
Room A209, Flounder Business Park, Shunbai Road 12, Chaoyang District, Beijing, China 100022 Page 10
Figure5.3
Connect TTL to device, as shown in Figure 5.4.
Figure5.4
Steps
1 Change jumper cap to hollow position (default it is in the solid position) as shown in
figure5.5.
2 Connect the TTL to the device as shown in figure 5.4.
3 Connect the device's power supply, as shown in figure5.6.
GND
RX
TX
Andere Handbücher für DF702
1
Inhaltsverzeichnis
Beliebte Steuereinheit Handbücher anderer Marken

Festo
Festo Compact Performance CP-FB6-E Stücklistenhandbuch

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Bedienungsanleitung

JS Automation
JS Automation MPC3034A Bedienungsanleitung

JAUDT
JAUDT SW GII 6406 Series Kurzanleitung

Spektrum
Spektrum Air Module System Bedienungsanleitung

BOC Edwards
BOC Edwards Q Series Bedienungsanleitung