DPS Telecom NetGuardian-16S Bedienungsanleitung

USER MANUAL
NetGuardian-16S
December 8, 2006
Visit our website at www.dpstelecom.com for the latest PDF manual and FAQs.
D-OC-UM06C.08103 Firmware Version 1.0

© 2005 DPS Telecom
This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this
document may be photocopied without prior written consent of DPS Telecom.
All software and manuals are copyrighted by DPS Telecom. Said software and manuals may not be reproduced, copied,
transmitted or used to make a derivative work, by either mechanical, electronic or any other means in whole or in part,
without prior written consent from DPS Telecom, except as required by United States copyright laws.
The material in this manual is for information purposes and is subject to change without notice. DPS Telecom shall not be
liable for errors contained herein or consequential damages in connection with the furnishing, performance, or use of this
manual.
Notice
December 8, 2006
October 2, 2006
November 8, 2005
Revision History
NetGuardian-16S User Manual (D-OC-UM06C.08103) released.
Supports Firmware Version 1.0.
NetGuardian-16S User Manual (D-OC-UM06A.02102) released.
Supports Firmware Version 1.0.
NetGuardian-16S User Manual (D-OC-UM05B.08101) released.
Supports Firmware Version 1.0.

ContentsVisit our website at www.dpstelecom.com for the latest PDF manual and FAQs
NetGuardian-16S Overview1 1
Shipping List2 2
Optional Accessories3 3
Specifications4 4
Installation5 5
Tools Needed5.1 5
Mounting5.2 5
Power Connection5.3 6
LAN Connection5.4 7
Telco Connection5.5 7
Alarm and Control Relay Connections5.6 8
Alarm and Control Relay Connector Pinout Table5.6.1 8
Discretes 1–24 Connector Pinout Diagram5.6.2 9
Discretes 25–32/Relays 1–8 Connector Pinout Diagram5.6.3 10
Data Ports5.7 11
NetGuardian Expansion Port5.8 11
Craft Ports5.9 12
Jumper Options — Switch Control Relays from Normally Open to Normally Closed5.10 13
Building Status Unit6 14
Standard Mode6.1 14
Standalone Mode6.2 15
Voice Call Out7 15
Voice Call Out Sequence of Operations7.1 16
LCD Display8 17
Alarm and Control Status Messages8.1 17
LCD Command Menu8.2 18
Sound off8.2.1 18
Reboot8.2.2 19
Run Config8.2.3 19
Contrast8.2.4 20
Alarm Speaker9 20
Front Panel LEDs10 21
Back Panel LEDs11 22
Connecting to the NetGuardian via Craft Port12 23
TTY Interface13 24

Menu Shortcut Keys13.1 25
Unit Configuration13.2 25
Ethernet Port Setup13.2.1 25
Edit PPP Port13.2.2 27
Monitoring13.3 28
Monitoring the NetGuardian13.3.1 28
13.3.1.1 Monitoring Base Alarms 28
13.3.1.2 Monitoring Ping Targets 29
13.3.1.3 Monitoring and Operating Relays (Controls) 30
13.3.1.4 Monitoring System Alarms 30
13.3.1.5 Monitoring Data Port Activity 31
Viewing Live Target Pings13.3.2 32
Proxy Menu13.3.3 33
Event Logging13.3.4 34
Backing Up NetGuardian Configuration Data via FTP13.3.5 34
13.3.5.1 Reloading NetGuardian Configuration Data 36
Debug Input and Filter Options13.3.6 37
Web Browser Interface14 38
Logging On to the Web Browser Interface14.1 38
Logging Out of the Web Browser Interface14.2 39
Other Top Frame Links14.3 39
Monitor and Edit Menus14.4 40
Monitor Menu14.5 41
Alarm Summary14.5.1 41
Base Alarms14.5.2 42
Ping Targets14.5.3 42
System Alarms14.5.4 43
Controls14.5.5 44
Event Log14.5.6 45
Port Transmit and Port Receive14.5.7 46
Edit Menu14.6 47
Call List14.6.1 47
Date and Time14.6.2 49
Reboot14.6.3 49
NVRam14.6.4 50
Reference Section15 51
NetGuardian-16S Alarm Map15.1 51
System Alarm Descriptions15.2 52
Voice Call Out Default Dialogs15.3 53
Dialog 1: Default Critical15.3.1 53

Dialog 2: Default Major15.3.2 53
Dialog 3: Default Secure Dial-In15.3.3 54
Dialog 4: Critical GR-47415.3.4 54
Dialog 5: Major GR-47415.3.5 55
Dialog 6: GR-474 Secure Dial-In15.3.6 55
Dialog 7: Critical RUS-FORM-52215.3.7 56
Dialog 8: Major RUS-FORM-52215.3.8 56
Dialog 9: RUS-FORM-522 Secure Dial-In15.3.9 57
NetGuardian-16S Trap OIDs15.4 58
SNMP Granular Trap Packets15.5 59
ASCII Symbol Descriptions15.6 60
Modem Access15.7 61
Technical Support16 62


1
NetGuardian-16S Overview1
Fig. 1.1. NetGuardian-16S: High capacity and versatile capabilities make it a powerhouse RTU
NetGuardian-16S — Proven Hardware and Software, New and Expanded Capabilities
The NetGuardian-16S is a multifunction, high capacity, NEBS-certified, LAN-based, SNMP/DCPx remote
telemetry unit. The NetGuardian-16S is based on the proven hardware and software capabilities of DPS
Telecom's popular NetGuardian-16S 832A RTU, but the NetGuardian-16S adds greatly expanded functionality.
The NetGuardian-16S incorporates many functions that previously required several separate units, while
occupying only 1 RU on any standard 19" or 23" equipment rack, freeing valuable rack space for
revenue-generating equipment.
The NetGuardian-16S features:
·Built-in Web Interface: monitor your alarms from any computer, without an alarm master
·Two separate IP addresses for security: one IP address for private company LAN access, and a second IP
address for public Internet access
·Voice Call Out for reporting alarms via telephone call
·Integrated Building Status Unit for local alarm visibility
·32 reversible discrete alarm inputs (expandable to 176 alarm points by adding NetGuardian-16S DX
Expansion Units)
·16 reach-through serial ports with terminal server functionality for connecting multiple concurrent
users via Telnet over LAN to telecom switches, servers, radios, PBXs and other equipment
·8 programmable NO/NC control relays (expandable to 32 by adding NetGuardian-16S DX Expansion
Units)
·32 ping alarms
·Automatic 24/7 email and pager alarm notification
·Alarm reporting to any SNMP manager or the T/Mon NOC Alarm Monitoring System
·Backup dial-up alarm reporting
·Dual –48 VDC power inputs
·Free lifetime firmware updates, installed via LAN or serial connection
·NEBS Level 3 compliance
Dual IP address security model for safe public access
For enhanced security, the NetGuardian-16S has two separate IP addresses on separate subnets. This allows you
to safely connect the NetGuardian-16S to both your private company LAN and the public Internet. Since the
public IP address is on a separate subnet, users from the outside cannot connect to your company LAN.
Connect via LAN to telecom switches, servers, radios and more
The NetGuardian-16S's 16 reach-through serial ports provide LAN-based terminal server access to up to 16 serial
devices Multiple users can simultaneously connect to the NetGuardian-16S via Telnet over LAN to connect and
control telecom switches, servers, radios, multiplexers, PBXs and many other types of remote site equipment.
NEBS-compliant for guaranteed reliability
The NetGuardian-16S is compliant with NEBS Level 3 electrical, environmental and safety standards.
NEBS-certified NetGuardian-16S models are available as an option.

2
Shipping List2
Please make sure all of the following items are included with your NetGuardian-16S. If parts are missing, or if
you ever need to order new parts, please refer to the part numbers listed and call DPS Telecom at
1-800-622-3314.
NetGuardian-16S NetGuardian-16S User Manual
D-PK-NETGD-12001 D-OC-UM06C.08103
NetGuardian-16S Resource CD DB9M-DB9F Download Cable 6 ft.
(includes manuals, MIBs, and software) D-PR-045-10-A-04
Two Ethernet Cables 14 ft. Telephone Cable 6 ft.
D-PR-923-10A-14 D-PR-045-10A-01
23" Rack Ears 19" Rack Ears
Eight 3/8" Ear Screws Four Standard Rack Screws

3
Four Metric Rack Screws Two 3/4-Amp GMT Fuse
Two Power Connector Plugs Pads
Optional Accessories3
Extend the capabilities of your NetGuardian-16S with these optional hardware accessories. To order or for more
information, call DPS Telecom at 1-800-622-3314.
NetGuardian Expansion (NetGuardian DX G4)
D-PK-NETDX-12022.00001
The NetGuardian Expansion G4 provides an additional 48 discrete and 8 analog alarm points. Up to three
NetGuardian Expansions can be daisy-chained off one NetGuardian-16S, providing a total of 176 discrete and 32
analog alarm points.
Building Status Unit (BSU)
D-PK-BSU02-12001
The Building Status Unit provides auxiliary local enunciation of alarms. The BSU features a single large
visual indicator for local alerts. Alarms may be acknowledged locally on the BSU, which will in turn
acknowledge the alarm in the NetGuardian-16S. Sound level of the audible speaker can be adjusted with
the volume control.

4
Specifications4
Discrete Alarm Inputs: 32 (reversible; expandable to 80, 138 or 176 alarm points)
Control Relays: 8 Form C (expandable to 16, 24 or 32 control relays)
Maximum Voltage: 60 VDC/120 VAC
Maximum Current: 1 Amp, AC/DC
Protocols: SNMP
DCPx, (T/Mon NOC reporting)
Interfaces: 16 RJ45 RS-232 reach-through serial ports (1200 to 115,200 baud)
2 50-pin connectors (discrete alarm inputs and control relay outputs)
2 RJ45 10BaseT Ethernet ports
1 RJ45 NetGuardian-16S Expansion port
1 RJ11 telco jack
2 DB9 front panel craft ports
Dimensions: 1.75" H x 8" W x 6" D (4.5 cm x 20.3 cm x 15.2 cm)
Mounting: 19" or 23" rack
Power Inputs: Dual –48 VDC (–40 to –70 VDC)
Current Draw: 200 mA (350 mA at power up)
Fuse: 3/4 Amp GMT
Modem: 33.6K internal
Visual Interface: LCD display
3 Critical-Major-Minor alarm status lights
30 bicolor LEDs
7 unicolor LEDs
Audible Notification: Alarm speaker
Unit Controls: 4 LCD menu control buttons
Operating Temperature: 32°–140° F (0°–60° C)
Operating Humidity: 0%–95% noncondensing
Inhaltsverzeichnis
Andere DPS Telecom Server Handbücher
Beliebte Server Handbücher anderer Marken

iRobo
iRobo IPC2U Bedienungsanleitung

Nortel
Nortel 1000 Con?guration guide Bedienungsanleitung

Asus
Asus AP7500 Bedienungs- und Wartungshandbuch

Avid Technology
Avid Technology AirSpeed 5000 Bedienungsanleitung

HP
HP Integrity rx2600 Installationsanleitung

Milestone
Milestone Husky IVO 350T Bedienungsanleitung