Dräger PAS MAC1000 Bedienungsanleitung

MOBILE BREATHING-AIR
COMPRESSOR
PAS MAC1000
OPERATOR’S HANDBOOK
Draeger Safety UK Ltd
Ullwater Close, Kitty Brewster Industrial Estate,
Blyth, Northumberland, NE24 4RG, UK
Tel No: +44 (0) 1670 352891
Fax No: +44 (0) 1670 356266
E‐mail:[email protected]
Website:www.draeger.ltd.uk

CONTENTS
Page
1 INTRODUCTION 1
2 GENERAL ARRANGEMENT
2.1 PAS:MAC1000 On Site 1
2.2 Compressor 2
2.3 Breathing-Air Components 2
3 TECHNICAL DATA
3.1 Compressor 3
4 OPERATING INSTRUCTIONS
4.1 Safety Precautions 4
4.2 Siting 4
4.3 Pre-operation Checks 4-5
4.4 Starting Instructions 5
4.5 Stopping Instructions 5
5 SERVICE
5.1 Before Working on the Compressor 6
5.2 Preventive Maintenance Schedule for the
Compressor 6
5.3 BA Filtration 7
5.4 Unloader Check Valve 8-9
6 SPARES
6.1 Standard Components 10
6.2 Service Spares 10
7 DRAWINGS
7.1 GA Drawing 11
7.2 Pneumatic Circuit 12
7.3 Electrical Circuit 13
8 CERTIFICATE OF CONFORMITY 14

PAS:MAC 1000 - 1 - OCTOBER 2010
INTRODUCTION
The PAS:MAC 1000 portable compressor set is designed to
deliver breathing quality air suitable for one man wearing air-fed
respiratory protective equipment.
A 230V/1.5kW electric motor driving a ‘V’ configuration twin
cylinder, reciprocating compressor, provides air which, after
processing, is purified to breathing quality conforming to EN 12021
(within certain environmental limitations). The compressor unit is
mounted within a tubular steel loop frame.
2.0 GENERAL ARRANGEMENT
2.1 PAS:MAC 1000 on site showing the unloader/check valve, power
supply lead and starter.

PAS:MAC 1000 - 2 - OCTOBER 2010
2.2 ATLAS COPCO LE15-10-S COMPRESSOR
2.3 BREATHING-AIR COMPONENTS
1 Outlet pressure gauge
2 Breathing-air outlet coupling
3 Pre-filter
4 Main coalescing oil removal filter
5 Activated carbon filter
6 Membrane dryer
7 Lockable outlet pressure regulator
3.0 TECHNICAL DATA

PAS:MAC 1000 - 3 - OCTOBER 2010
3.1 COMPRESSOR
The compressor is a lubricated, twin cylinder, single stage
reciprocating unit; air is drawn through an air filter mounted in
between the cylinders. After compression the air passes through
an unloader/check valve, an aftercooler and finally a pulsation
vessel mounted under the unit before passing through a set of
filters to provide air of breathable quality.
Model Atlas Copco LE15-10-S
Nominal Operating Speed 1500 rpm
Oil Grade Atlas Copco PAO oil
Maximum Working Pressure 10 bar
Oil Capacity 0.8 litres
Free Air Delivered (FAD) 3.4 l/sec (7.2 cfm @ 7 bar at
Normal Temperature & Pressure
[NTP])
Electric Motor 1.5kW TEFV
Supply Voltage 230V 50 Hz 1ph
Dimensions
Length 980 mm
Width 586 mm
Height 770 mm
Weight 115 kgs
Outlets One CEJN (other safety lock
types available)

PAS:MAC 1000 - 4 - OCTOBER 2010
4.0 OPERATING INSTRUCTIONS
4.1 SAFETY PRECAUTIONS
In addition to normal safety rules which should be observed with
stationary air compressors and equipment, the following safety
directions and precautions are of special importance.
When operating this unit, the operator must employ safe working
practices and observe all related local work safety requirements
and ordinances.
The owner is responsible for maintaining the unit in a safe
operating condition. Parts and accessories shall be replaced if
unsuitable for safe operation.
Installation, operation, maintenance and repair shall only be
performed by authorised, trained, competent personnel.
Never remove or tamper with the safety devices, guards or
insulations fitted on the unit.
4.2 SITING
Position the compressor on firm, level ground.
Site in a well-ventilated area well away from any source of
hazardous gas, dust or vapour so that any contamination created
by the work to be undertaken does not drift towards the
compressor.
WARNING: The breathing-air filtration will not remove carbon
monoxide or carbon dioxide, therefore position the compressor
well away from any potential vehicle exhaust contamination.
4.3 PRE-OPERATION CHECKS
Check the compressor’s oil level which must be near the top of the
red circle of the sight glass. The minimum level is the lower part of
the red circle.
Top up, if necessary, by slowly unscrewing the filler cap. If there is
any escape of oil/air DO NOT CONTINUE REMOVING THE CAP
UNTIL ALL PRESSURE IS RELEASED. (The filler cap is located
between the cylinders on top of the compressor casing.)

PAS:MAC 1000 - 5 - OCTOBER 2010
Electrical cable - visually inspect cable and plug for
damage. Statutory insulation
inspections may be required – see local
rules.
Note:Electric cable and plug can be stowed within the tool box.
Ensure cable is run through the cut-out in the front of the box
when in use.
Aftercooler - visually inspect for damage/leaks.
Running up checks - start compressor and check for leaks.
Compressor pressure should be 8.5 bar.
Outlet pressure maybe adjusted using
the regulator fitted.
Condensate - check condensate collection bottle.
Note: Dispose of collected condensate
in an environmentally safe way.
4.4 STARTING INSTRUCTIONS
Plug into a 230 volt single phase power supply and press the
green starter button.
4.5 STOPPING INSTRUCTIONS
Ensure the machine is not supporting life before pressing the red
stop button.

PAS:MAC 1000 - 6 - OCTOBER 2010
5.0 SERVICE
5.1 BEFORE WORKING ON THE COMPRESSOR
Potentially lethal voltages are used to power this machine.
Disconnect power lead from mains supply prior to carrying out any
service work.
Do not undertake any work until the compressor and pulsation
vessel have been relieved of all pressure.
Wait until the compressor’s vent down cycle is complete.
Release any pressure contained in the aftercooler or associated
pipework.
Check that the air-end pressure gauge reads zero. Do not
proceed until it does.
5.2 PREVENTIVE MAINTENANCE SCHEDULE FOR THE COMPRESSOR
The schedule contains a summary of the maintenance instructions.
When servicing, replace all disengaged packings, eg gaskets, ‘O’
rings, washers.
The “longer interval” checks must also include the “shorter
interval” checks.
MAC1000 Service Schedule
Service Interval
Annually
Service Operation Note Daily Annually
500 hrs 6 months
1000 hrs 1000
hrs 2000
hrs
Check compressor’s oil level 1
Check/clean compressor’s air intake filter 3
Check/empty condensate collection bottle
Check electrical connections are tight
Change compressor oil
Change compressor’s air intake filter
Change breathing-air pre-filter element
Change breathing-air main (coalescing) filter
element
Change breathing-air activated carbon filter
element
Test safety valve 2
Notes: 1 Maintain the oil level in the red circle of the sight glass.
2 Wear gloves and safety glasses.
3 For normal operation in clean surroundings, more
frequently when operating in a dusty environment.

PAS:MAC 1000 - 7 - OCTOBER 2010
5.3 BREATHING-AIR FILTRATION
Item Description Part NoService Interval
1 Pre-filter element FIL 0471 2000 hours/12 months
2 Main coalescing filter element FIL 0473 2000 hours/12 months
3 Activated carbon filter element FIL 0475 1000 hours/ 6months

PAS:MAC 1000 - 8 - OCTOBER 2010
5.4 UNLOADER CHECK VALVE
OPERATION
The Mark II maintains air vessel pressure levels between a “cut-
out” pressure level and a “cut-in” pressure level. The difference
between the two is known as the “differential”. The Mark II senses
air pressure through a small orifice in the side of the OUT port of
the valve.
At low pressure levels, all compressor discharge air passes
through the Mark II into the air vessel. When the vessel pressure
reaches the desired cut-out pressure, the VENT port on the Mark II
opens and allows all compressor discharge air to be vented to
atmosphere through the VENT port. At the same time, a check
valve internal to the Mark II closes and prevents any stored air
from being vented out of the VENT port.
As air is used the the air vessel the pressure drops and, at the
desired cut-in pressure, the valve changes back to its original
configuration where all compressor discharge air is flowing through
the valve into the air storage vessel. This cycle continues,
therefore maintaining stored pressure levels between the cut-out
and cut-in levels.