6
In the assembly, install the Sounder with 3 screws and dowels. The screw
and dowel used should be compatible with the external environment. Since
the use of 3 screws and dowels will ensure the device to be fixed properly, it is
especially recommended to be used.
20m maximum to the alarm control panel. It is recommended to be mounted
away
To open the cover, the Sounder is placed on a flat surface.
MESSAGES AND DEFINITIONS
Recommended mounting conguration, xing methods,
prohibited areas, mounting location and location features
6
7
INTRUSION
When the PIR detector detects motion in the environment, it sends
the Intrusion information, and when the Intrusion is removed, sends
information for removal of intrusion.
SABOTAGE
In case of sabotage, a tamper status signal is sent to the control
panel. In addition, if the Sounder is registered on the panel, the
Sounder gives an audible and visual warning when sabotage occurs.
Audible and visual warning continues from the panel until the alarm
is resolved or the alarm time of the Sounder expires.
ERROR
MESSAGE
When the battery voltage drops below 4.2V, low battery information
is sent to the main panel.
SELF
TEST
It is checked whether the buzzer and flasher LEDs work or not.
Failure information is transmitted to the panel in case of any
malfunction.