Edwards R Series Betriebsanleitung

R-Series Remote
A
nnunciators and
Expanders Installation and
Operation Guide
P/N 3100969-EN • REV 05 • ISS 06MAY13

Copyright © 2013 UTC Fire & Security Americas Corporation, Inc..
Trademarks and
patents
The R-Series Remote Annunciators and Expanders name and logo
are trademarks of UTC Fire & Security Americas Corporation, Inc..
Other trade names used in this document may be trademarks or
registered trademarks of the manufacturers or vendors of the
respective products.
Manufacture
r
Edwards, A Division of UTC Fire & Security
Americas Corporation, Inc.
8985 Town Center Parkway, Bradenton, FL 34202, USA
Version This document applies to R-Series Remote Annunciators and
Expanders version 2.0x.
FCC compliance Class A: This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own
expense.
2002/96/EC (WEEE directive): Products marked with this symbol
cannot be disposed of as unsorted municipal waste in the European
Union. For proper recycling, return this product to your local supplier
upon the purchase of equivalent new equipment, or dispose of it at
designated collection points. For more information see:
www.recyclethis.info.
Contact information For contact information, see www.edwardsutcfs.com.

R-Series Remote Annunciators and Expanders Installation and Operation Guide i
Content
Introduction to the R-Series#1
Installation terminals and controls#4
Installing annunciators and expanders#6
Wiring diagrams#8
Troubleshooting#10
Specifications#11
Operating the LCD models#12
Operating the LED models#15
Reading LCD displays#18
System Normal screen#18
Event Message screen#18
Details screen#19
Entering a password#20
Message priorities#21

ii R-Series Remote Annunciators and Expanders Installation and Operation Guide

R-Series Remote Annunciators and Expanders Installation and Operation Guide 1
Introduction to the R-Series
The R-Series Remote Annunciators and Expanders provide remote annunciation
for fire and emergency alarm systems. The annunciators offer LCD or LED
annunciation, and can include common controls. The expander uses LEDs.
The R-Series includes three annunciator models and one expander model. One
or two expanders can be connected to any of the annunciator models. Figure 1
shows the four models in the R-Series. Table 1 lists the features of each model.
Table 2 is a complete list of all models and accessories in the series.
Figure 1: Models in the R-Series
Table 1: Features of the models
Model LCD
Display
Zone
LEDs
Common
controls
System
LEDs
Buzzer
RLCD, RLCD-R, RLCDF Yes No No Yes Yes
RLCD-C, RLCD-CR, RLCD-CF Yes No Yes Yes Yes
RLED-C, RLED-CR, RLED-CF No 16 pairs Yes Yes Yes
RLED24, RLED24R No 24 pairs No No No
The annunciators and expanders can be mounted on a standard 4 in. square
electrical box, using the included mounting ring. They can also be surface
mounted in locking steel enclosures.
Controls Enabled
Ack/Silence
Reset
Signal Silence
Drill
Lamp Test
Power
Alarm
Supervisory
Ground Fault
Trouble
Controls Enabled
Ack/Silence
Reset
Signal Silence
Drill
Lamp Test
Power
Alarm
Supervisory
Ground Fault
Trouble
RLCD-C
RLED-C
RLCD
RLED24
Controls Enabled
Ack/Silence
Lamp Test
Power
Alarm
Supervisory
Ground Fault
Trouble

2 R-Series Remote Annunciators and Expanders Installation and Operation Guide
The annunciators communicate with the FACP on the RS-485 data riser. This
can be configured for Class A or Class B communication. The annunciators do
not provide ground fault isolation.
The annunciators are stand-alone units that can be powered by the FACP or by
an approved power supply.
Models with common controls can use a separate, remote key switch to enable
or disable the common controls.
Table 2: R-Series models and accessories
Model number Description
RLCD Remote Annunciator: LCD text annunciator without common controls.
English.
RLCD-R Remote Annunciator: LCD text annunciator without common controls.
English. Red.
RLCDF Remote Annunciator: LCD text annunciator without common controls.
French.
RLCD-C Remote Annunciator: LCD text annunciator with common controls.
English.
RLCD-CR Remote Annunciator: LCD text annunciator with common controls.
English. Red.
RLCD-CF Remote Annunciator: LCD text annunciator with common controls.
French.
RLED-C Remote Annunciator: 16-pair LED zone annunciator with common
controls. English.
RLED-CR Remote Annunciator: 16-pair LED zone annunciator with common
controls. English. Red.
RLED-CF Remote Annunciator: 16-pair LED zone annunciator with common
controls. French.
RLED24 Remote Expander: 24-pair LED zone expander with expander cable and
zone card insert.
RLED24R Remote Expander: 24-pair LED zone expander with expander cable and
zone card insert. Red.
RA-ENC1 One-position enclosure for Remote Annunciator.
RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote
Expander, including one interconnection cable.
RA-ENC3 Three-position enclosure for Remote Annunciator and two Remote
Expanders, including two interconnection cables.
RKEY Remote key switch on plate for enabling or disabling common controls
(Lock/Unlock).
RA-LED16ZC Zone card insert for RLED-C, RLED-CR, and RLED-CF.
RA-LED24ZC Zone card insert for RLED24, RLED24R.

R-Series Remote Annunciators and Expanders Installation and Operation Guide 3
Part number Description
27193-16 Electrical box, surface mount, white, single-gang.
7300073 24-inch expander cable assembly, includes cable and hardware.
7120313-01 12-inch expander cable (cable only).
7120313-02 24-inch expander cable (cable only).

4 R-Series Remote Annunciators and Expanders Installation and Operation Guide
Installation terminals and controls
Figure 2: Annunciator rear view showing terminals and controls
(1) Mounting slot
(2) DIP switch
(3) Annunciator bus IN/OUT terminals
(4) Power riser IN/OUT terminals
(5) Transmit and receive communication LEDs
(6) Remote key switch terminals
(7) Expander cable terminals
Figure 3: Expander rear view showing terminals
(1) Mounting slot
(2) Expander cable IN terminals
(3) Expander cable OUT terminals
(1)
(2)
(3)
(4)
(5)
(6
)
(7
)
V (-)
OUT
V (+)
F
E
D
C
B
A
V (-)
IN
V (+)
F
E
D
C
B
A
(1)
(2) (3)

R-Series Remote Annunciators and Expanders Installation and Operation Guide 5
Table 3: DIP switch settings
Switch Description
S1 to S5 Annunciator address.
The annunciator address (in binary). The factory setting is for address 2.
See Table 4 for examples. Possible values: 1 to 31.
S6 Baud rate.
OFF = 9600 baud (factory default setting)
ON = All other baud rates
S7 Annunciator circuit type.
OFF = Circuit supports Class B and Redundant Class B wiring
ON = Circuit supports Class B and Class A wiring
S8 Not used.
Table 4: Examples of DIP switch address settings
Address Setting Address Setting
1
ON
12 34 5 678
6
ON
12 34 5 678
2
ON
12 34 5 678
7
ON
12 34 5 678
3
ON
12 34 5 678
8
ON
12 34 5 678
4
ON
12 34 5 678
16
ON
12 34 5 678
5
ON
12 34 5 678
31
ON
12 34 5 678

6 R-Series Remote Annunciators and Expanders Installation and Operation Guide
Installing annunciators and expanders
For correct operation, the annunciator must be configured with a unique address,
must have the correct baud rate setting, and must be in communication with the
FACP.
If you are installing a Remote Annunciator and Remote Expanders into RA-ENC2
or RA-ENC3 enclosures, you must install the expanders first. Refer to the
installation sheets for the enclosures for the correct sequence of steps.
If you are installing Remote Annunciators and Remote Expanders using separate
electrical boxes, the wire runs between the boxes must be enclosed in conduit.
If you are installing a remote key switch, the switch must be located within the
enclosure or within 3 ft. (0.9 m) of the enclosure with the cabling installed in
conduit or equivalent protection against mechanical injury.
To install an annunciator:
1. Secure the mounting ring to the electrical box, as shown in Figure 4.
2. Use the DIP switch to set the correct address and baud rate. See Table 3 on
page 5 for DIP switch settings.
3. Connect the control panel annunciator circuit to the appropriate annunciator
terminals. See Figure 5, Figure 6, Figure 7, and Figure 8.
Tip: Leave enough wire to remove and position the annunciator when setting
the DIP switch.
4. Attach the expander cable to the annunciator, if applicable. See Figure 9.
5. Attach the remote key switch wiring to the annunciator, if applicable. See
Figure 8.
6. Tilt the annunciator up and slide the mounting slot onto the top flange of the
mounting ring, as shown in Figure 4.
7. Tilt the annunciator down and push the bottom of the annunciator over the
stud-nut.
8. Secure the bottom of the annunciator to the mounting ring using the captive
screw.
9. Cover the screw hole with the product label plate.
To install an expander:
1. Complete and insert the zone card (labeling sheet) into the expander.
2. Secure the mounting ring to the electrical box, as shown in Figure 4.
3. Connect the expander cable to the expander. Attach an expander cable for
interconnection to a second expander, if applicable. See Figure 9.
Dieses Handbuch passt für folgende Modelle
11
Inhaltsverzeichnis
Beliebte Fernbedienung Handbücher anderer Marken

Panasonic
Panasonic EUR7622KB0 Bedienungsanleitung

Bang & Olufsen
Bang & Olufsen Beo4 Bedienungsanleitung

Sunwave Tech.
Sunwave Tech. RemoteComm SRC-7000 Bedienungsanleitung

Multiplex
Multiplex PROFI TX 9 Bedienungsanleitung

One Remote
One Remote RMB4 Bedienungsanleitung

FUTABA
FUTABA 9ZAP - PART2 Bedienungsanleitung











