Elecro Engineering H.R.UV-C SPA-STANDARD Montageanleitung

H.R.UV-C SPA - STANDARD
Installation & Operating Manual
HR-30-B-SPA
ENGLISH

2
CONTENTS
IMPORTANT NOTES...............................................................................................................................3
1. IMPORTANT SAFETY INSTRUCTIONS...........................................................................................3
2. PRODUCT OVERVIEW ....................................................................................................................3
3. GENERAL INSTALLATION INSTRUCTION.....................................................................................5
3.1 Mounting instructions......................................................................................................................5
3.2 Pipe work........................................................................................................................................5
3.3 Flow direction .................................................................................................................................6
3.4 Connection .....................................................................................................................................7
3.6 Electrical connection.......................................................................................................................8
4. OPERATING INSTRUCTIONS .........................................................................................................9
4.1 Flow requirements..........................................................................................................................9
4.2 Water quality...................................................................................................................................9
5. MAINTENANCE................................................................................................................................9
5.1 Essential parts to carry out annual maintenance including our reference codes. ............................9
5.2 Lamp replacement and quartz sleeve cleaning.............................................................................10
6. DISPOSAL OF ELECTRICAL/ELECTRONIC EQUIPMENT...........................................................12
7. WARRANTY...................................................................................................................................13

3
IMPORTANT NOTES
Thank you for purchasing the H.R.UV-C SPA pool sanitising system, the latest in high reflection UV
technology, manufactured to the highest standards in England.
To ensure years of trouble-free service, please read and follow these instructions for proper installation,
maintenance and use. Incorrect installation will affect your warranty.
Please retain this manual for future reference.
1. IMPORTANT SAFETY INSTRUCTIONS
WARNINGS:
•Read the maintenance instructions before opening the appliance.
•Do not operate the ultraviolet-C emitter when it is removed from the appliance enclosure.
•Unintended use of the appliance or damage to the housing may result in the escape of
dangerous ultraviolet-C radiation. ultraviolet-C radiation may, even in little doses, cause
harm to the eyes and skin.
•This unit must be earthed.
•Power must be supplied through a Residual Current Device (RCD) with a rated residual
operating current not exceeding 30mA
•Do not run this unit dry
•Do not cover this unit
•The unit must not be submerged in water
•Carefully examine the unit after installation. It should not be powered on if there is water
on any parts not intended to be wet
•If the unit shows any sign of water leakage immediately disconnect power supply
•If the quartz sleeve is cracked, replace it immediately
•To avoid injuries young children should never be allowed near UV steriliser
•Failure to disconnect the power from the UV steriliser and pump before servicing or
maintenance could result in personal injury or property damage.
2. PRODUCT OVERVIEW
The H.R.UV-C SPA is available in 30W single tube format.

4
Fig.1
Dimensions:
Fig.2

5
3. GENERAL INSTALLATION INSTRUCTION
3.1 Mounting instructions
The device should be either installed horizontally or vertically allowing enough space for the pipe
connections, wiring and maintenance of lamps/quartz sleeve(s). It should be firmly secured, using the
fixing kit provided, to a solid wall.
NOTE: When mounting the UV, it is essential to leave a clearance space of at least 1 metre
from one side of the unit to allow access to replace the lamp(s) and/or quartz
sleeve(s) when required. Both the lamps and the quartz sleeve can be replaced
from either end of the unit; if installing vertically the 1m clearance space must be
above or below the unit, if installing horizontally the 1m clearance space must be to
the left or right of the unit.
WARNING: The device must be installed within a dry, permanent weather-proof area. In any
case where water or moisture enters the enclosure the warranty will be void.
Caution: If the device is unused during the winter months, it must be drained to prevent frost
damage. Water must not be allowed to freeze inside the unit as this will cause severe
damage.
See Fig. 3 for mounting instructions when securing to the wall or floor.
Fig.3
3.2 Pipe work
The device should be placed downstream (after) of any pumps, filters and heating devices but upstream
(before) of any chemical dosing or similar water treatment (see Figs. 4 and 5).

6
Fig. 4
3.3 Flow direction
The device is factory set to accept input water flow entering on the left and exiting on the right,

7
Fig. 6
3.4 Connection
The unit is supplied with unions to allow connection to 2" or 63-mm rigid pipe. Reducers are also supplied
to allow connection to 50-mm or 1½" rigid pipe - see Fig 7.
For pipework 63-mm or 2” in diameter.
For pipework 50-mm or 1½“ in diameter.

8
Fig. 7
All factory unions are made from ABS plastic, when gluing connections to an ABS pipe an ABS cement
must be used or when using a PVC pipe, a Transition cement must be used (See Fig. 7).
There is no need to use mastic or PTFE tape to connect unions to the device, use the O-rings provided to
put in the groove on the end of the Manifold Assembly.
NOTE: Be sure to apply the glue evenly and to all surfaces that will be in contact to reduce the
risk of leakage.
3.6 Electrical connection
WARNINGS:
•This device must be installed by a qualified Electrician following the
instructions provided in this manual. The manufacturer will not be liable
for any issues caused by poor or improper installation.
•Any alterations made to the unit (unless stated) will affect the warranty.
This also applies if components are changed for non-standard
components acquired anywhere other than direct from the manufacturer.
•Incorrect installation may result in serious damage to property/persons.
•The device must be installed in accordance with the country/regional
requirements and regulations and an Electrical Installation Certificate
must be provided on completion of the installation.
•The power supply must be fitted with a 30mA RCD.
•Never look directly at an illuminated UV lamp.
WARNINGS:
•This device must be installed by a qualified Electrician following the
instructions provided in this manual. The manufacturer will not be liable
for any issues caused by poor or improper installation.
•Any alterations made to the unit (unless stated) will affect the warranty.
This also applies if components are changed for non-standard
components acquired anywhere other than direct from the manufacturer.
•Incorrect installation may result in serious damage to property/persons.
•The device must be installed in accordance with the country/regional
requirements and regulations and an Electrical Installation Certificate
must be provided on completion of the installation.
•The power supply must be fitted with a 30mA RCD.
•Never look directly at an illuminated UV lamp.

9
4. OPERATING INSTRUCTIONS
4.1 Flow requirements
Minimum flow rate:
•1m3/hour (1,000 litres per hour)
Maximum flow rate:
•30W (Mini) = 12m3/hour (12,000 litres per hour)
•A higher flow rate will require the installation of a bypass to prevent damage to the unit
The unit should be wired in such a way that it can only be energised when the swimming pool filtration
pump is energised and running, under no circumstances should the UV unit be energised without flowing
water being present. Note: This is best achieved by wiring the H.R.UV-C SPA unit into the output side of
the filtration pump contactor.
4.2 Water quality
The water quality MUST be within the following limits:
•PH: 6.8 –8.0
•Total Alkalinity (TA): 80 –140 ppm (parts per million)
•Chloride Content MAX: 150 mg/litre
•Free Chlorine: 2.0 mg/litre
•Total Bromine: Max 4.5 mg/litre
•Total Dissolved Solids (TDS)/Calcium hardness: 200 –1,000 ppm
WARNING: Failure to meet the water quality limits will void the warranty.
Upon completion of the installation, run the water-circulating pump to purge the system and heater of air
(i.e. remove any trapped air in the system).
5. MAINTENANCE
To avoid any water leaks and optimum performance annual maintenance of the UV steriliser is
essential. Failure to do so could result in damage to the product and significant drop in efficiency.
Annual maintenance includes:
•Changing of lamps(s) if necessary. Fig. 8.
•Inspection and cleaning of quartz sleeve. Replace if any cracks are discovered. Fig. 9.
•Replacing all O-rings. Fig. 10.
•Replacing lamp connectors (white plastic insert inside the blue bulb cap) if corroded, wet,
damaged or overheated.
5.1 Essential parts to carry out annual maintenance including our reference codes.
WARNING: Before performing any maintenance isolate from the main power supply, turn off
circulation pump and drain the unit.
SP-UV-LAMP-30-AM SP-UV-QS-30
Fig. 8 Fig. 9

10
SP-UV-ORS
Fig. 10
5.2 Lamp replacement and quartz sleeve cleaning
Removing the lamp and quartz sleeve
Unscrew all the highlighted fasteners
Unclamping the clip from body
1. Pull the clip in shown direction to
unlock from body
2. Pull the second side after unlocking the
1st side
Remove Lamp holder Clip from Hard cap
Unmount the Hard cap from Blue lamp Holder
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Elecro Engineering Beleuchtungsausrüstung Handbücher
Beliebte Beleuchtungsausrüstung Handbücher anderer Marken

Qazqa
Qazqa Suplux SL 3 Black 103062 Bedienungsanleitung

Commercial Electric
Commercial Electric 54568141 Bedienungsanleitung

CREE LIGHTING
CREE LIGHTING 304 Series Bedienungsanleitung

Goobay
Goobay 49867 Bedienungsanleitung

ECOMAN ITALIA
ECOMAN ITALIA LED T8 Bedienungsanleitung

Alkalite
Alkalite Krypton KT-81 Bedienungsanleitung