ElectrIQ PowerPod 2 Bedienungsanleitung

1Installation Manual
Installation Manual
for the
Electriq PowerPod 2
V. 031121b
The Smart Home Battery Solution

2Installation Manual
This installation manual applies to the following PowerPod 2
configurations:
Available capacity PowerPod 2 capacity 10,15, 20 kWh with continuous
power output of 5, 6, 7.6, 8.6, 9.6 kW options.
PP2 - AC - BAT<Capacity> - INV<Output Power>
PP2 - DC - BAT<Capacity> - INV<Output Power>

3Installation Manual
TABLE OF CONTENTS
Table of Contents
1. Introduction 4
1.1. Whole Home Backup Configuration 5
1.2. Partial-Home Backup Configuration 6
2. Safety Warnings 7
3. Installation and Commissioning 17
3.1. Prerequisites 17
3.1.1. Planning for Installation 17
3.1.2. Tips for Success 18
3.1.3. Commissioning 19
3.2. Mounting System 20
3.2.1. Battery Enclosure(s) 23
3.2.2. Inverter 24
3.2.3. Auto-Transformer 29
3.2.4. Automatic Transfer Switch 31
3.3. Installing System 32
3.3.1. General Requirements 32
3.3.2. Conduits 35
3.3.2.1. Conduit and Plugs 35
3.3.3. Battery 36
3.3.4. Auto-Transformer 49
3.3.5. Inverter 51
3.3.5.1. Connect Battery to Inverter 52
3.3.5.2. CTs 53
3.3.5.3. PV (DC-Coupled Only) 56
3.3.5.4. Grid 59
3.3.5.5. Whole Home 61
3.3.5.5.1.
Automatic-Transfer Switch
61
3.3.5.6. Partial-Home (DC-Only) 63
3.3.5.7. PowerHub 67
3.3.6. Finalize Commissioning 69
3.3.6.1. Attach Front Cover 69
3.3.6.2. Turn On System 69
3.3.6.3. Finalize Commissioning 70
3.4. Homeowner Walkthrough 72
4.
Appendix
73
4.1.
What's in the Box
73
4.2.
Enclosure Dimensions
78
4.3.
Technical Specifications
84
4.4.
Marks of Conformity
92
4.5.
Warranty
93

4Installation Manual
1. INTRODUCTION
The PowerPod 2 is a high-performance fully integrated home energy
storage, management, and monitoring system powered by LFP (cobalt-
free) batteries. The product includes a hybrid solar/battery inverter
controlled by intelligent software. It comes in both whole home and
partial-home backup. Whole home backup has two options for the
solar connection, 1) the AC option which keeps the solar connected
directly to the load and 2) the DC-coupled option which connects solar
directly to the PowerPod 2 inverter.
All PowerPod 2 models manage grid and backup power from PV
panels, batteries, and the utility. When the PV panels generate
enough power, the system will support the backup load, charge the
batteries and feed back to the grid all at the same time. When the
power generated by the PV panels is not sucient to support the
backup load, the inverter takes power from either the batteries or
the utility depending on the mode the homeowner has selected. For
multi-day grid outages the system will resupply power to the home
by restarting from solar each day and solar charge the batteries even
if the batteries were completely drained and system shut down the
previous day. PowerPod 2 comes in dierent inverter and battery sizes
and configurations to match your energy and backup needs. There are
six Inverters models ranging from 5000 to 9600 W and three batteries
sizes; 10, 15 and 20 kWh.
Introduction

5Installation Manual
Intro / Whole Home Backup Configuration
1.1. WHOLE HOME BACKUP CONFIGURATION
+
-
~
Back-up output breaker
Meter CT Communication
Grid
Power meter
Main Panel
Backed-up Home Loads
Grid side
Battery
DC Breaker
NTC
BMS
On-grid output breaker
Main breaker
RESET
FAULTWi-FiCOMENERGYGRIDBATTERYBACK-UPSYSTEM
Solar array
Solar array
DC-Coupled Option
or
AC-Coupled Option
DC-Coupled Option
AC-Coupled Option
Solar Inverter
Automatic transfer switch
Auto-transformer
+
-

6Installation Manual
1.2. PARTIAL-HOME BACKUP CONFIGURATION
Intro / Partial-Home Backup Configuration
Inverter Nameplate
Check the inverter nameplate
located on the side of the inverter
labeled 'Model' to determine
which system you have.
DC-coupled is the A-ES inverter
and the AC-Coupled is the A-BP
inverter.
Option only available for DC-coupled systems (inverter model A-ES).
Back-up output breaker
Meter CT Communication
Grid
Power meter
Main Panel
and
Non-backed-up loads
Grid side
Battery
DC Breaker
NTC
BMS
On-grid output breaker
Main breaker
RESET
FAULTWi-FiCOMENERGYGRIDBATTERYBACK-UPSYSTEM
Solar array
DC-Coupled Only
Auto-transformer
+
-
Back-up Partial Load
A-ES

7Installation Manual
Safety Warnings
2. SAFETY WARNINGS
READ ALL INSTRUCTIONS AND CAUTIONARY MARKINGS ON THE
UNIT AND THIS MANUAL BEFORE USING THE INVERTER. STORE
MANUAL IN A LOCATION FOR EASE OF FUTURE ACCESS.
WARNING: Users should not attempt to service the Electriq PowerPod
2. Only an authorized PowerPod technician should attempt to service
the Electriq PowerPod 2.
Safety Symbols
WARNING. This indicates the risk of electric shock. The
presence of high voltage levels may constitute a risk of
injury or death to users and/or installers.
CAUTION. This indicates important information where
failure to comply may result in safety hazards or cause
damage to this product.
CAUTION. This indicates the risk of a hot surface. The
surface may reach a temperature high enough to cause
serious burn injuries.
General Precautions
CAUTION. Before installing and using this inverter, read all
instructions and cautionary markings on the inverter and
all appropriate sections of this guide. This inverter must be
installed by licensed electricians only.
CAUTION. Normally grounded conductors may be
ungrounded and energized when a ground fault is
indicated.
CAUTION. Due to inverter weight it is to be lifted by at
least two people for safety.
WARNING. These servicing instructions are for use by
qualified personnel only. To reduce the risk of electric shock,
do not perform any servicing other than that specified in
the operating instructions unless you are qualified to do so.

8Installation Manual
WARNING. Authorized service personnel should reduce
the risk of electrical shock by disconnecting AC,DC and
battery power from the inverter before attempting any
maintenance or cleaning or working on any circuits
connected to the inverter.Turning o controls will not
reduce this risk. Internal capacitors can remain charged
for five (5) minutes after disconnecting all sources of
power.
WARNING. Do not disassemble this inverter yourself. It
contains no user-serviceable parts. Attempting to service
this inverter yourself may cause a risk of electrical shock or
fire and will void the warranty from the manufacturer.
WARNING. To avoid a risk of fire and electric shock, make
sure that existing wiring is in good condition and that the
wire is not undersized. Do not operate the Inverter with
damaged or substandard wiring.
CAUTION. Under high temperature environment, the cover
of this inverter could be hot enough to cause skin burns if
accidentally touched. Ensure that this inverter is away from
normal trac areas.
WARNING. During the installation process, drilling,
punching, and screwing the bolts can cause metal burrs,
which must be cleaned up to prevent them from falling
into the electronics.
WARNING. Use only recommended accessories.
CAUTION. To reduce risk of fire hazard, do not cover or
obstruct the cooling fan.
CAUTION. Do not operate the Inverter if it has received a
sharp blow, been dropped, or otherwise damaged in any
way. If the Inverter is damaged, call for an RMA (Return
Material Authorization).
WARNING. Exposed hazardous voltage, during servicing
or for emergency procedures use a lockable manual
breaker lockout on the main service panel disconnects to
enable Lock-Out-Tag-Out per the Standard for Electrical
Safety in the Workplace, NFPA 70E, and the Standard for
Workplace Electrical Safety, CSA Z462.
Safety Warnings

9Installation Manual
Safety Warnings
BATTERY PACK WARNINGS:
There is danger of generating heat / smoke / rupture flames.
Do not disassemble battery pack.
Do not touch disassembled battery pack.
Do not reassemble battery pack.
Do not immerse the battery pack in any liquids or get it
wet.
Do not short circuit battery pack.
Do not incinerate or heat the battery pack.
Do not use or leave the battery near a fire, stove or heated
place.
Do not impact the battery pack or throw it.
Do not use a damaged and/or deformed battery pack.
Do not drive sharp objects into the battery pack, strike it
with any object or stand on it.
Do not place the battery pack on materials such as tools,
electric wire, screws, etc.
In case of a leak in the battery pack, avoid contact.
Do not touch your eyes if accidental contact with leaky
battery.
Do not expose to corrosive substances such as sea breeze,
steam or chemicals.
Do not install in humid places or places with condensation.
Do not install or use the Electriq PowerPod 2 if it has been
damaged in any way.
The ambient temperature (charging) must be between
0°C and 55°C; discharging temperature must be between
-20°C and 55°C; relative humidity must be between 10 and
90% to ensure optimal operation. Do not operate where the
temperature and humidity are beyond the specified limits.
High ambient temperature above 45°C will cause power
derating.

10 Installation Manual
Safety Warnings
WARNING. Only charge the Electriq PowerPod 2 within
the specified conditions (e.g. temperature range, voltage,
current, etc. Failure to do so may result in damages, heat
generation, smoke, fire, or explosion.
The unit has a Pollution Degree rating of PD4 (Electrical
equipment for outdoor use). The unit must be mounted
with clearances listed and have adequate air flow. i.e. Must
not be in a closed room smaller than 12' x 12' x 8'.
Do not directly solder the Electriq PowerPod 2. This
may result in damages, heat generation, smoke, fire, or
explosion.
The unit was designed with an NEMA 3R protection rating
and is for indoor and outdoor applications.
It is recommended that the installation of the enclosures
should be prevented from direct sunlight, snow, rain and
other negative influences which may cause function impact
or life aging.
CAUTION. Do not expose the Electriq PowerPod 2 to liquids
or flooding.
Do not dispose of equipment or batteries with household
waste.
Do not dispose of batteries in a fire or by burning. The
batteries can explode.
WARNING: Risk of electric shock. Risk of fire. Do not
attempt to repair the battery(ies); it contains no user-
serviceable parts. Tampering with or opening the
battery(ies) will void the warranty.
If the battery(ies) fails, contact Electriq Power Customer
Support for assistance at support@electriqpower.com.
WARNING: Proper disposal of lithium-ion batteries is
required. Follow all local codes and regulations for proper
disposal and recycling of lithium ion batteries.
Contact your Electriq Power representative with any
questions or concerns. The customer cannot keep the old
lithium-ion batteries because they are dangerous and
considered hazardous waste.
WARNING: Take care when lifting the Battery. The Battery
is heavy and may require a lifting tool to initially lift the
battery high enough to get a good hold on it.
Dieses Handbuch passt für folgende Modelle