CONTENTS
1. INTRODUCTION.................................................................................................................................................................. 3
1.1 PRECAUTIONS..................................................................................................................................................................... 3
2. INSTALLATION ................................................................................................................................................................... 3
2.1 PACKAGE CONTENTS.......................................................................................................................................................... 3
2.2 METAL PAN ASSEMBLY........................................................................................................................................................ 4
2.3 PLACING AND LEVELLING THE SCALE................................................................................................................................. 4
2.4 POWER CONNECTION ......................................................................................................................................................... 4
2.5 RECHARGEABLE BATTERY .................................................................................................................................................. 5
2.5.1 Fitment............................................................................................................................................................................. 5
2.5.2 Charging.......................................................................................................................................................................... 5
3. OVERVIEW .......................................................................................................................................................................... 6
3.1 DIMENSIONS........................................................................................................................................................................ 6
3.2 DISPLAY............................................................................................................................................................................... 7
3.3 KEYBOARD .......................................................................................................................................................................... 7
3.4 VIEW FROM BELOW ............................................................................................................................................................. 8
3.5 CONNECTIONS..................................................................................................................................................................... 8
3.5.1 RS232 interface port...................................................................................................................................................... 8
3.5.2 Scale to PC interface cable.......................................................................................................................................... 8
4. OPERATION ........................................................................................................................................................................ 9
5. USER SETTINGS.............................................................................................................................................................. 14
5.1 MENU NAVIGATION............................................................................................................................................................ 14
5.2 USER SETTINGS MENU -OVERVIEW ................................................................................................................................ 14
6. TECHNICAL DATA............................................................................................................................................................ 17

3
1. INTRODUCTION
This document contains information about how to install and operate your S200 price computing
scale. Please read carefully the manual before using the device.
1.1 Precautions
•Use the manufacturer approved power adapter provided with the scale. The use of
improper type of adapter could damage the device.
•Do not place loads heavier than the maximum weight limits specified in this document.
•Place loads carefully on the weighing pan.
•Do not immerse the scale in water or any other liquids.
•Do not use the scale in hazardous environments.
•The scale should be used in environments free from dust, high humidity, corrosives,
vibrations, extreme temperature fluctuations and excessive air movements.
•Do not place the scale on unstable surfaces.
•Avoid placing the scale near heaters or in direct sunlight.
•Switch off and disconnect the scale from the power supply before cleaning or servicing.
•Always grab the scale from the bottom when moving, do not grab the weighing pan.
•Disposal of this product and its accessories should be in accordance with your local
regulations.
2. INSTALLATION
2.1 Package Contents
Inside the package you should find:
✓Scale
✓User manual
✓Metal pan
✓Rechargeable Li-on battery 3.7V (optional)
✓Power adapter (AC 5V/500mA)
✓RS232 interface cable (optional)

4
2.2 Metal Pan Assembly
Place the metal pan on top of the scale as shown in the image below and push gently
downwards.
Fig. 2.1 –Fitting metal pan
2.3 Placing and Levelling the Scale
Ensure the scale is placed on a levelled and stable surface free from vibrations and away from
direct sunlight.
Once you have located the scale, level it by adjusting the four rotational regulation feet at the
bottom of the device so the bubble in the level indicator positioned under the front display is fully
centered.
Fig. 2.2 –Levelling indicator
2.4 Power Connection
S200 is powered through the manufacturer approvedAC power adapter. First connect the
adapter cord to the scale’s power input jack and then plug the adapter to the power outlet.
Fig. 2.4 –Power adapter cord connection

5
2.5 Rechargeable Battery
S200 has the option to be fitted with a rechargeable 3.7V Li-on battery which allows the scale to
operate independently from an external power supply making it perfect for outdoors usage.
2.5.1 Fitment
Before placing the battery, you must ensure the scale is switched off and disconnected from the
power adapter cord. Remove the metal pan and then open the dedicated battery compartment as
illustrated in the image below. Connect your battery, make sure the compartment is fully closed
and finally place the metal pan back.
Fig. 2.3 –Battery Compartment
2.5.2 Charging
The battery is automatically charged once the power adapter is connected and the scale. The
battery charge level is indicated with the symbol provided in the front display. Once the
charge is critically low, the indicator will be fully empty and will start flashing. Please note the
scale will automatically switch off, once the battery is too low in order to protect it from damaging.

6
3. OVERVIEW
3.1 Dimensions
Fig. 3.1 - Model S200B Dimensions
Fig. 3.2 - Model S200L Dimensions

7
3.2 Display
Main Information shown on front display:
1.
Weight
2.
Unit price
3.
Total amount
4.
Metrological characteristics
5.
Level indicator
6.
Stability indicator
Table 3.1 –Main display information
Fig. 3.3 –Front Display
Additional Information shown on front display:
-0-
Gross weight is zero
Net
Net weight
T
Tare is displayed
PT
Preset Tare is active
X
Scale is in by-count mode
FIX
Unit price and/or tare is fixed
100g
100 g pricing is activated
Battery level indication
Table 3.2 –Additional information on front
3.3 Keyboard
S200 has a light touch waterproof membrane keyboard with 20 functional keys and 12 hot
keys for PLU commands.
Keyboard Functional Zones
1.
PLU preset keys
2.
Advanced function keys
3.
Numeric keys
4.
Basic functions
Table 3.3 –Keyboard
Information
Fig. 3.4 –Keyboard Layout
Further information about the keys functionality is provided in the following ‘Operation’ section.

3.4 View from below
Fig. 3.5 –View from below
1.
Power supply connection
2.
RS232 interface connection
3.
Calibration seal
4.
Adjustable feet
Table 3.4 –View from below
information
3.5 Connections
3.5.1 RS232 interface port
Fig. 3.6 –RS232 port
Signal
RS232 Port
TXD
5
RXD
4
GND
3
3.5.2 Scale to PC interface cable
Scale Connector PC Connector
RJ11 6P4C DB9 Female
Fig. 3.7 –Scale to PC cable connectors
Signal
SCALE
Male
RJ11 6C4P
PC
Female
DB9
TXD
5
2
RXD
4
3
GND
3
5

4. OPERATION
Operation
Description
4.1 Turning the Scale ON
Press the key key. At start up the scale runs a short display test procedure. All display segments light up briefly
and the software version is displayed in the price to pay line. The scale is ready to use once the weight display appears.
4.2 Turning the Scale OFF
Press and hold the key until you hear a beep.
4.3 Free price/kg input sale
If you would like to sell a product and enter a specific unit price e.g 2.59 €/kg, place the item on the scale and then enter
. This will automatically calculate the price for the item you are weighing.
4.4 Zeroing
Due to residues on the weighing pan or external influences, it is possible that the weight display of an unloaded weighing
pan to show a value different from 0.000kg. In such cases the scale can be rest back to zero by pressing the key.
Please note the maximum allowed deviation to be compensated by zeroing is +/- 2 % of the maximum scale capacity.
4.5 Creating a PLU
1. Press and hold the key for 2 seconds.
2. Enter a PLU number of your choice (e.g ) and store it by pressing . Please note the PLU number can be
between 1 and 70.
3. Enter a €/kg price of your choice (e.g ) and store it by pressing the key.
4. Press the key to exit the PLU mode.

Operation
Description
4.6 Storing a PLU to Hot keys
You can assign a hot key to the most frequently used PLUs as follows:
1. Enter a price/kg of your choice e.g. 2.55 €/kg .
2. Press and hold the hot key you have chosen (e.g. ) until you hear a long beep.
4.7 Calling PLU by keyboard
1. Place your item on the scale
2. Input PLU number (e.g. )
3. Press key and unit price as well as price to pay will be displayed.
4.8 Calling PLU by Hot keys
1. Place your item on the scale.
2. Press a hot key of your choice (e.g. ) and unit price as well as price to pay will be displayed.
Please note if 2 PLUs per hot key function is activated, double pressing the hot key will show the second saved price.
4.9 Calling PLU automatically
1. Auto PLU function needs to be activated in the user menu.
2. Place your item on the scale.
3. Input PLU number (e.g. ) and unit price as well as price to pay will be automatically displayed.
4.10 Working with TARE
1. Place Tare weight on the scale
2. Press key. The weight will be stored and the scale will show 0.000kg with the NET symbol being present.
3. Place your item. Now the scale will show only the NET weight of the weighted item.