Elinchrom RX 1200 Bedienungsanleitung

English
elinca SA switzerland www.elinchrom.com
Operating Manual
Style RX 300 Style RX 600 Style RX 1200
Elinca S.A Style RX 01.01.2007 ENG (73253) Printed in Switzerland
Version 230V - 20625 Version 230V - 20626 Version 230V - 20627
120V - 20725 120V - 20726 120V - 20727
Canada 120V - 20725.1VS Canada 120V - 20726.1VS Canada 120V - 20727.1VS

1
P.S: Technical data subject to change.
The listed values are guide values which may vary due to tolerances in components used.
Introduction 2
Declaration of conformity, disposal and recycling, CE marking 3
Safety notice and precaution 4
Operating instructions 5
Control Panel 6
Switch and Fuse 7
Modelling Light 8
Digital power display, Photo-cell 9
Sychronisation, Wireless Remote control and ash triggering 10
Acoustic signal 10
Troubleshooting 7, 10
Flash tube replacement 11
Technical Data 12
Elinchrom Accessories 13
Guarantee 14
Table of contents

2
The quality of light and exceptional performance is the result of long research, application of
demanding principles, the long experience of ELINCHROM in lighting products for the studio
and the utilization of the latest technology in this area.
Totally integrated to the range of the ELINCHROM ashes, the Style 300RX - 600RX -
1200RX units maintain the traditional look and function that is ELINCHROM.
The control provides continuously variable adjustment of the modelling lamp and the ash
power with precision over 6 f-stop, from full power 1/1 to 1/32 th.
Style 300RX - 600RX - 1200RX
The Elinchrom Style RX is manufactured by Elinca S.A. CH -1020 Renens/Switzerland
Dear Photographer,
Thank you for buying your Style RX compact ash unit.
All Elinchrom products are manufactured using the most advanced technology. Carefully selected
components are used to ensure the highest quality and the equipment is submitted to many controls
both during and after manufacture. We trust that it will give you many years of reliable service.
All Style RX ash units are manufactured for the studio and location use of professional photogra-
phers. Only by observance of the information given, can you secure your warranty, prevent possible
damage and increase the life of this equipment.
Note:
This equipement has been tested and found to comply with the limits for a class B digital device, pursuant to Part
15 of the FCC Rules and meets all requirements of the Canadian Interference-Causing Equipement Regulations.
These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipement generates, uses, and can radiate radio frequency energy and, if not installed and
used in accordance with the instruction manual, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this equipement
does not cause harmful interferences to radio or television reception, which can be determined by turning the
equipement off and on, the user is encouraged to correct the interferences by one or more of the following
measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipement and receiver.
- Connect the equipement into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
ELINCA S.A. is not responsible for any radio or television interference caused by unauthorised modications of
this equipement or the substitution or attachment of connecting cables and equipement other than those specied
by ELINCA S.A. The correction of interference caused by such unauthorised modication, substitution or
attachment will be the responsibility of the user.
FCC Class B Compliance Statement
Introduction

3
CE marking
The shipped version of this device complies with the requirements of ECC directives
89/336/ECC «Electromagnetic compatibility» and 73/23/ECC «Low voltage directive».
Notational Conventions
The meaning of the symbols and fonts used in this manual are as follows:
Pay particular attention to text marked with this symbol.
Failure to observe this warning endangers your life, destroys the device, or may
damage other equipement
Supplementary information, remarks, and tips follow this symbol.
Text which follows this symbol describes activities that must be performed in the
order shown.
«Quotation marks» indicate names of chapters or terms
!
i
Disposal and recycling
This device has been manufactured to the highest possible degree from materials
which can be recycled or disposed of in a manner that is not enviromentally
damaging. The device may be taken back after use to be recycled, provided that is
returned in a condition that is the result of normal use. Any components not reclaimed
will be disposed of in a environmentally acceptable manner.
If you have any question on disposal, please contact your local ofce or your local ELINCHROM
agent (check our website for a list of all ELINCHROM agents world wide).
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause
undesired operation.
Product name: Professional Studio Flash unit
Trade name: ELINCHROM
Model number(s): Style RX 300/600/1200
Name of responsible party: Elinca S.A
Av. De Longemalle 11
1020 Renens / Switzerland
Phone : +41 21 637 2677
Fax: +41 21 637 2681
We, ELINCA S.A., hereby declare that the equipement bearing the trade name and model number
specied above was tested conforming to the applicable FCC rules, and that all the necessary steps
have been taken and are in force to assure that the production units of the same equipement will
continue to comply with the Comissions requirements.
Declaration of conformity

4
Transport
• Transport the ash unit with care and only in its original packaging or another corresponding
packaging t to protect it against knocks and jolts.
• Transport only in complete discharged conditions. Wait a minimum 30 minutes after removing
from mains supply before packaging and transportation.
• Never drop the ash unit (danger of breaking ash tubes)
Power cable
To guarantee safe operation, use the cable supplied.
• The cable has to be HAR-certied or VDE-certied. the mark HAR or VDE will appear on the outer
sheat.
• The cable set must be selected according to the rated current for your ash unit.
• Do not use a spider box to connect one or more ash units.
!
FLASH SYSTEMS STORE ELECTRICAL ENERGY IN CAPACITORS BY APPLYING HIGH
VOLTAGE.
FOR YOUR SAFETY, NEVER OPEN OR DISASSEMBLE YOUR FLASHES.
ONLY AN AUTHORISED SERVICE ENGINEER SHOULD OPEN OR ATTEMPT TO REPAIR
THE UNITS.
INTERNAL DEFECT CHARGE CAPACITORS MAY EXPLODE WHILST THE UNIT IS IN
USE, NEVER SWITCH ON A PROPER WORKING FLASH UNIT.
According to safety regulations, we draw your attention to the fact that these
electronic ash units are not designed for use outdoors, in damp or dusty conditions and should
not be used after being exposed to sudden temperature changes causing condensation. They must
always be connected to an earthed (grounded) mains supply.
On no account should any object be inserted into the ventilation.
The units may retain an internal charge for a considerable time even though disconnected from the
power supply.
Do not use in restricted area (like hospitals) and in explosive environnements.
Flash Tubes and Modelling lamps
• Flashtubes and modelling lamps in use are very hot!
• Never touch a ash tube or lamp before the unit cooled down and is disconnected from the mains.
• Do not re ashes from short distance (less than 1m) directed to a person and avoid looking
directly into the ashlight!
• Keep distance to ammable materials.
• Keep generally distance to operating units.
Safety notice

5
B
protective
cover
3
1
6
11
12
The Style RX unit voltage must correspond with your mains voltage. Style RX are delivered in 120V
or 230V versions.
Before connecting for the rst time, check to make sure that
your Modelling lamp coincides with the voltage line.
They must always be connected to an earthed ( grounded) mains supply.
All Style RX units have a bayonet mount and locking ring reector tting, for xing all Elinchrom and
Prolinca accessories.
Mount the unit securely to a suitable stand or support.
Remove the black protective cover (note: rst turn the locking ring A as shown, then rotate the
black cap cover B in the same direction).
Fitting a reector or accessory is the reverse of this action.
1.Check that the modelling lamp voltage is correct.
2.Check that the mains switch (3) is in the OFF ("O" position).
3.Insert mains cable to the MAINS INLET (1) and connect to a FULLY EARTHED OUTLET
4.Using the mains SWITCH (3) and switch the unit ON ("I" position).
5.Connect the synchro cord on the socket (6).
6.Select the power with the touch pad (11 - 12)
Operating instructions C
A
locking
handle
tilthead with locking
Before you start !

6
Overview of controls
1.Mains inlet socket
2.Mains fuse (slow blow)
3.Mains Illuminated on/off switch
4.Modelling fuse (fast blow)
5.Open-ash
6.Synchro-sockets, Amphenol + jack 3.5 mm
7.Digital power display and
charge/discharge indicator
8. Acoustic recharging signal (Beep)
9. Slave cell switch on/off
10. Photocell receptor
11. Power adjustment in 1/10 f-stops, with
ADF
12. + Power adjustment in 1/10 f-stops
1 3. Modelling lamp switch
(on/off free or prop)
14.+ Modelling power control
15. - Modelling power control
16. Tilt head clamp
17. Knurled clamp screwad clamp

2
3
1
Mains fuse 8 AT
Modelling fuse 4 AF
Mains switch
(Only tempered)
Mains socket
4
Mains Supply
With the MAINS SWITCH (3) switched off ("O" position), rmly push in the plug
of the original ELINCHROM mains cord into the mains socket (1).
Mains Switch
The switch should light up when the compact is switched on ("I" position).
(Switch off before removing the mains cord).
Troubleshooting
If the on/off switch (3) is ON ("I" position) but not illuminated,
switch off the unit and check the mains fuse (2).
If failed replace with the correct fuse and switch ON the unit.
This unit is protected by a thermal circuit breaker to avoid overheating.
Should this occur, the unit turns off automatically and cannot be red.
After a break for cooling, the ash will be ready again for operation.
See page 10 / Troubleshooting
This equipment is not user serviceable and contains high voltages which are dangerous.
In the event of failure, please return the unit to an authorized Elinchrom service station.
Mains Fuse
Standard type 5 x 20 mm, (use only tempered fuse)
• Style 300RX : 5 AT
• Style 600RX : 6,3 AT
• Style 1200RX : 8 AT
Note: Before exchanging a blown fuse, switch off the unit and remove mains cable. Depress and turn the fuse
holder anti-clockwise 1/8th, turn and remove it. If the new fuse blows immediately upon reconnection, return
the unit to an ELINCHROM service centre for a check-up.
(N.B. Please don't forget to check the correct rating of the fuse !).
Fuse for modelling light
Fast type 5 x 20mm, 2.5 AF
Switch off the unit and replace the blown fuse with a new one of the correct rating.
The fastblow fuse will protect the triac of the modelling lamp circuit, the lamp and therefore
the ash tube.
7

8
23018
23101
23022
230V Modelling lamps and fuses
Unit Modelling lamp Code Socket Fuse Code
Style 300RX 250W halostar 23018 E27 2,5AF 19033
Style 600RX 250W halostar 23018 E27 2,5AF 19033
Style 1200RX 300W halogen 23022 GX 6,35 2,5AF 19033
The touch pad (14) controls the modelling lamp on/off and the proportional light.
Select the power with the touch pad (15). The modelling light output (100%) is achieved when
the power value is set to maximum.
Proportional modelling lamp, is set when the position "PROP" is selected (led is illuminated), the
light output is proportional to the selected ash power.
For all types of Style RX compact ash units, use maximum 250 - 300W modelling lamps.
This lamp socket adapter E27 to GX 6.35 (code 23101) allows the use of the halogen lamp
300W, GX 6.35 (code 23022) for Style 300 and 600 RX units.
If the modelling lamp does not light up.
1. The lament is broken after long use (replace lamp and fuse)
2. The lament is broken after shock (replace lamp and fuse)
3. An internal component failure (return the unit to customer service)
Modelling Light
120V Modelling lamps and fuses
Unit Modelling lamp Code Socket Fuse Code
Style 300RX 150W halogen 23037 BA15D 4 AF 19035
Style 600RX 150W halogen 23037 BA15D 4 AF 19035
Style 1200RX 250W halogen 23038 BA15D 4 AF 19035
120V «Canada Version» Modelling lamps and fuses
Unit Modelling lamp Code Socket Fuse Code
Style 300RX 150W halogen 23012 E27 4 AF 19035
Style 600RX 150W halogen 23012 E27 4 AF 19035
Style 1200RX 150W halogen 23012 E27 4 AF 19035
230V Modelling lamp options: 120V Modelling lamp:
23037

9
10
Photocell
receptor
5
Test and ready
Cell 9
Modellling
light controls
Power display
The actual ash power is displayed in a f-stop compatible format.
The power range is 6 f-stops. The digital display, provides continuous power indication of the
ash and modelling lamp. The controls cover a continuous output range from full power 1/1 to
1/32th in 1/10th, f-stop intervals.
During charging or discharging, the display "ashes". In case of overheating or malfunction,
the display shows "ER" for error.
Note:
This "Style 300RX, 600RX and 1200RX" units have an integrated discharge system, protected by a
thermic switch.
To avoid overheating, lower power settings, more than 2f-stop, can be discharged manually by releasing
the ash with the «Test» touch button.
The photocell is actived when the green LED (on the touch pad 9) is illuminated.
When switched ON, the unit can be remotely triggered by another ash unit !
The Style BX photocell is specially designed to work under ambiant light conditions in your stu-
dio. Direct light or other strong light sources may reduce the sensitivity of the cell.
In difcult situations e.g. blinding, sunlight or obstacles, the additional cell with 5 m cord
(extensions available) solves most problems.
Additional cell : code 11081
Extension cord 10 m : code 11080
Digital Power Display
Photocell
Andere Handbücher für RX 1200
1
Dieses Handbuch passt für folgende Modelle
2
Inhaltsverzeichnis
Andere Elinchrom Kamerablitz Handbücher

Elinchrom
Elinchrom D-Lite 4 it Bedienungsanleitung

Elinchrom
Elinchrom RX 1200 Bedienungsanleitung

Elinchrom
Elinchrom Ringflash 3000 Bedienungsanleitung

Elinchrom
Elinchrom Style BX 100 Bedienungsanleitung

Elinchrom
Elinchrom ONE Bedienungsanleitung

Elinchrom
Elinchrom ELC 125 Bedienungsanleitung

Elinchrom