TECHNICAL MANUAL
BLADERF
Advanced wireless IR detector
for door and windows protection
090020839

2
090020839 - BLADERF -TECHNICAL MANUAL
info@elmospa.com
elmospa.com
WARNING
FOR THE INSTALLER:
Please follow carefully the specifications relative to electric and security systems realization further to the manufacturer's
prescriptions indicated in the manual provided.
Provide the user the necessary indication for use and system's limitations, specifying that there exist precise specifications and
different safety performances levels that should be proportioned to the user needs. Have the user view the directions indicated
in this document.
FOR THE USER:
Periodically check carefully the system functionality making sure all enabling and disabling operations were made correctly.
Have skilled personnel make the periodic system's maintenance. Contact the installer to verify correct system operation in case
its conditions have changed (e.g.: variations in the areas to protect due to extension, change of the access modes, etc…)
......................................................
This device has been projected, assembled and tested with the maximum care, adopting control procedures in accordance with
the laws in force. The full correspondence to the functional characteristics is given exclusively when it is used for the purpose it
was projected for, which is as follows:
Advanced wireless IR detector for doors and windows protection
Any use outside of this area is not provided and it is not possible to guarantee its proper operation, and therefore it is expressly
forbidden to the holder of this manual to use it for other reasons than those indicated.
The manufacturing process is carefully controlled to prevent defects and malfunctions; nevertheless the components used is
subjected to faults extremely low percentage, as indeed it does for every other electronic or mechanical.
Given the target of this article (property and persons protection) invite the user to proportion the protection level offered by the
system to the actual risk (considering the possibility that the system it is operating in degraded mode due to faults or other),
reminding that there are clear rules for the design and construction of equipment to this type of application.
The system's operator is hereby advised to see regularly to the periodic maintenance of the system, at least in accordance with
the provisions of current legislation, as well as to carry out checks on the correct running of said system on as regular a basis
as the risk involved requires, with particular reference to the control unit, sensors, sounders, dialler(s) and any other device
connected. The user must let the installer know how well the system seems to be operating, based on the results of periodic
checks, without delay.
Design, installation and servicing of systems which include this product, should be made by skilled staff with the necessary
knowledge to operate in safe conditions in order to prevent accidents. These systems' installation must be made in accordance
with the laws in force. Some equipment's inner parts are connected to electric main and therefore electrocution may occur if
servicing was made before switching off the main and emergency power. Some products incorporate rechargeable or non
rechargeable batteries as emergency power supply. Their wrong connection may damage the product, properties and the
operator's safety (burst and fire).
Your dealer:

090020839 - BLADERF -TECHNICAL MANUAL
elmospa.com
1. GENERALS
The BladeRF detector is a advanced wireless IR detector with reduced-dimension and high-performance, desi-
gned to protect windows, French-windows or doors thanks to their precise curtain coverage. It can be installed
in vertical position, at the side of the window or door, or in horizontal above the window, fixed under the roller
platform. The detector BladeRf allows to realize an efficient perimeter protection via radio at three levels, in fact
is possible to connect a magnetic contact and a detector for shutter to the corresponding terminals.
For installation between shutters/roll-up shutters and windows/doors, the detector is equipped by special paths
in the case base and seals to prevent the water ingress when the cables enter laterally.
The detector functionality is selectable through dipswitches, the encoding used by the radio section can be se-
lected to be compatible with the protocol used by Helios system or by the Villeggio system with fw. 5.x or higher.
Note: for Villeggio control unit series with previous firmware at the version 5.0.0, select the HELIOS protocol, the
Villeggio protocol is supported only by Villeggio control unit series with firmware 5.0.0 or higher and
other compatible devices.
One key point of detector is the use of a digital PIR to obtain a very high immunity to noise and accuracy of
detection.
The detector is equipped with blue LEDs to display the periodic transmission and the alarm.
At the time of first power supply, the detector automatically goes into Walk Test for faster functionality test.
The nice aesthetic appearance facilitates installation in any kind of environment.
2. FEATURES
2.0.1 GENERAL FEATURES
• Wireless IR detector with reduced-dimension and high-performance.
• Transmission protocol selectable via Helios radio system or Villeggio.
• Designed to realize via radio an effective perimeter protection at three levels, IR – Magnetic contact –
Shutter detector.
• Horizontal/vertical installation.
• It can be placed to protect a roll-up/windows-door, shutter/door-windows, roll-up/windows, shutter/win-
dow etc.
• DIGITAL PIR sensor high immunity with temperature compensation.
• Silicon filter against dazzle.
• Sensitivity adjustable in two step.
• IR lens with vertical curtain protection with 15° horizontal coverage angle and with 90° vertical coverage
angle, range 4m for maximum protection of the window or door area.
• Blue LED indicator for operation signaling through the lens.
• Terminal inputs for the magnetic contact connection with tamper protection and a roll-up shutter.
• Internal dip-switch for remote test control.
• Power supplied by 1/AA 3,6V Lithium battery (supplied).
• Low supply voltage detection with code transmission of the corresponding event.
• Transmissions of alarms, tamper events, magnetic contact alarms, roll-up shutters alarms and supervi-
sion events.
• Timing for the supervision transmission towards the receiving device with cadence fixed every 26 minu-
test.
• The detector is provided with an identification code programmed at the factory to further speed the
installation, the stored code is randomly chosen from a base more than 2 billion combinations (231).
• Extremely compact dimensions.
• Plastic detector housing with a pleasant design, input arrangements for the connecting cables and
gaskets for side access.

4
090020839 - BLADERF -TECHNICAL MANUAL
info@elmospa.com
elmospa.com
2.1 Features
The BladeRf detector complies with EN50131-5-3 + A1 at level 1and level 2 for the environmental class.
The Blade detector has passed tests conducted in accordance with the directive EMC 2004-108-EC with tests
carried out in accordance with EN 50131-2-2 level 1 for IR section, EN 50130-4 + A1+ A2 regarding immunity
Model: BLADERF
Performance level: I level CEI 79-2, level B CEI 79-16, EN50131-5-3 grade 1, EN50131-2-2 grade 1.
Power supply: 3,6V from battery ½ AA 3,6V to Lithium (supplied).
Discharge battery detection: if less than 2.8V (3.2V idle state)
Minimum operating voltage: 2.7V for LEDs, 2.4V RF section
Power consumption detector @3.6V
Stabilization power: 120 A
At rest: 28 A
IR alarm, open magnetic
contact and roll-up shutter
sensor: 16 mA
Functions selection: dipswitch on board, see wiring diagram.
TX frequence: digital broadcasts on frequencies for LPD devices (Low Power Devices).
TX protocol: Selectable with selector for compatibility with Helios or Villeggio system.
Connection range: 120 meters in open space subject to limitations dependent on environmental conditions.
Average life: 2 years with HELIOS Protocol, 2.5 years with Villeggio Protocol.
Note: the calculation considers 20 total transmissions per day and a supervision
transmission every 26 min.
Operations timings
First power on: 10s disabling the IR section, the other input are active.
Walk-test time: Activated at the first power on with a duration of 5 min or reset from the first movement of
the magnetic contact or the roll-shutter.
Wait time between first IR pulse
and second IR pulse: 10s only with minimum sensitivity.
IR inhibition time in Walk-Test
after alarm transmission: 3 s.
Alarm from roll-up shutter input: 5 impulses in 15 s.
Supervision time: Transmission every 26 min.
IR
Lens type: Vertical curtain lens.
Sensitive zones: 2 beams.
Coverage area: see installation diagrams.
Range: Max. 4 mt, see installation diagrams.
PIR sensor: Digital immune to RF interference. Silica filter against gazzle (provided).
IR gain stage: Optimized with the temperature.
Views: blue LED visible through the lens.
Operating states displayed: fixed lighting for state as before power;
triple flashes for transmission during the Walk-Test,
single flash for IR pulse during the Walk-Test,
single flash for RF transmission in operation.
Connections: terminal for connection of the magnetic contact, shutter sensor, tamper input.
Protection: protection against the opening of the case.
Operating temperature: -10 / +55 °C.
Humidity: 93% U.r.
Dimensions: H 96 - W 35 - D 33,5 mm (vertical position).
Wheelbase drilling: 65 mm.
Weight: 65 g.
Parts supply: screws, dowels, technical manual, battery 3.6 V, with bag labels for capacity reduction.

090020839 - BLADERF -TECHNICAL MANUAL
elmospa.com
and EN 61000-6-3 concerning electromagnetic emissions. For the radio section has been carried out according
to ETSI EN 300220-3, ETSI EN 301489-3.1, EN50131-5-3 + A1 for grade 1. The detector BladeRf complies with
the R & TTE 199/5/CE. For the aspects of electrical safety have been complied with requirements of Directive
LVD 2006-95-EC with tests carried out in accordance with EN 60950-1.
3. INSTALLATION
3.1 Open, fixed and close operation of the case
The installer must operate in total absence of electrostatic charges alrea-
dy opening the case, make sure that the electronic card of the detector
can be damaged by electrostatic discharge. The precautions should be
observed during the installation phase and during maintenance.
1) Unscrew the fixing screw of the cover on the upper part of the case,
indicated with A.
2) Separate the front cover by releasing the latches marked with Bby tur-
ning fulcrum in B.
3) The closing operation of the cover requires the invert execution of the
operations previously exposed, taking the utmost care to ensure that
the closing spring of the Tamper protection microswitch indicated with
C is seated correctly, conclude the fixing operation by screwing the
self-tapping screw of the cover. Finally you will have to insert the cap I
for masking the front screw.
Posting operations and hang-up the board:
1) Remove the fixing screw of the printed circuit indicated by D.
2) Pull out the circuit board by gently twisting it and moving it forward
upwards to release it from the lower hook indicated by E.
3) The operation of the hang-up board to bottom of the case requires in-
vert execution of the operations previously exposed.
Drilling and wall installation:
1) Proceed to the positioning and fixing of the bottom
using as template the detector holes indicated with F
(distance 65 mm) after analyzing the possibilities of
installation and understand the instructions and re-
strictions highlighted in this manual.
Cable routing:
1) In case of magnetic contact and/or sensor connectior for shutter, the
cables must be inserted into the hole Gat the center of the cable cover
channel. The introduction path of the cable is facilitated by the plastic
bottom suitably shaped, to the side entrance there are two entrances,
when not in use they must be sealed with supplied plastic plugs.

6
090020839 - BLADERF -TECHNICAL MANUAL
info@elmospa.com
elmospa.com
3.2 General warnings
- The curtain detector must be entered in interstice between window \ French-windows and its shutter \ roll-up,
the opening of the protection area is approximately 80° longitudinally and 15° transversely.
- Can be installed horizontal or vertical: horizontal is recommended in case of doors, about windows can be
install horizontally or vertically. Check position of Dip1 according to the position of fastening defined.
- The installation should be performed:
A)If vertical with the lens downward and ceiling detector.
B)If horizontal with the lens towards the center of the window\door and the detector approached the edge wall.
In both cases, for clarity it is recommended to refer to the installation examples.
- Connect any sensor for shutter and the magnetic contact respecting the instructions in the chapter of the
electrical connections.
3.3 Effects of building materials and furnishings
The BladeRf installation must respect certain rules to avoid a drop in performance due to positioning errors. In
fact, it is vitally important to define with the greatest care the operating area of the receiving system in which the
transmitter is installed, the actual sensors coverage and the correct installation especially in relation to the nature
of the materials used in the building construction.
The drawings below show the correct and wrong installation positions, objects that can attenuate the RF signal
and the attenuation of some building materials.
Attenuation of the radio signal by some typical materials of construction.
Posterior view:

090020839 - BLADERF -TECHNICAL MANUAL
elmospa.com
Items that can modify and/or reduce the capacity with HELIOS control unit.
Items that can modify and / or reduce the capacity with Villeggio series control unit.

8
090020839 - BLADERF -TECHNICAL MANUAL
info@elmospa.com
elmospa.com
3.4 Installation for window protection and coverage diagram
3.5 Installation for door protection and coverage diagram

090020839 - BLADERF -TECHNICAL MANUAL
elmospa.com
3.6 Detector installation - suggestions
In horizontal installation is imperative to mount the de-
tector with the lens facing the center of the door or
window and the body of the detector approached the
corner.
In vertical mounting is imperative to put the detector
with the lens facedown and the body of the detector
approached the corner at the top.
Top view of the BladeRf range for windows protection:
Resulting capacity with BladeRf installed to the outside of the wall:

10
090020839 - BLADERF -TECHNICAL MANUAL
info@elmospa.com
elmospa.com
4. ELECTRICAL CONNECTIONS
Internal board view:
Information provided by the blue LED:
Terminal connections:
Stable turned on= stabilization at first powered. Single flashing= Sensor in Walk-test, IR single
pulse
Triple flashing= RF transmission during the walk-
test.
Single flashing in
operation= RF transmission