Elsema 240S1 Series Bedienungsanleitung

Controller Card for 240VAC Motors
used on Light Commercial Doors, Industrial Roller Shutters,
Sectional Doors, Garage Doors, Sliding Doors and Swing Gates
VERSION 3
www.elsema.com
240S1
240S2

2Controller Card for 240VAC Motors
Features
• Adjustableautoclose
• Adjustableslowspeedforopenandclose
• Deadmancontrolsforopenandcloseinputs
• Automaticgroundandtraveldistancecalibration
• Photocell,pedestrianandwirelessremotecontrolinputs
• Externalkeyswitchforsafetyandsecurity(Onlyon240S2)
• SupportsNCorNOlimitswitchinputsortraveltimersetup
• Auxrelayoutputtocontrolcourtesylightsandotheraccessories
• 24VDCoutputtosupplyexternalaccessoriessuchasloopdetectors,swipecardsetc
• Toroidaltransformerforexcellentefciencyandlowleakagelossesreducingyourelectricity
consumption.DynamicPowerSavings
• Customisedmodelsavailableuponrequest,120S1and120S2forinternationalmarkets
Description
The240S1and240S2areverysimilarcardsexceptforthecardsizeandthe240S2hasakey
switchinput.Offeringtwodifferentsizesallowsthecardstobeeasilyinstalledintoexistingcasesas
replacementorupgradecards.Thesetwocardsareoneofourbestvaluedcardsonthemarket,selling
foraverycompetitiveprice,yetstillloadedwithmanyfeatures.
Thecontrolcardswerebuiltfromthegroundup,basedoncustomerfeedbackandusingtoday’s
technology.Withitsrichfunctions,consumerfriendlypriceandwiththefocusduringdevelopment
beingeaseofuseandsetupmakesthese240VACcontrolcardstheultimateboardtocontrol
yourmotors.
Atoroidaltransformerisusedtopowerthecontrolcardandcontactors.Usingatoroidaltransformer
offersthefollowingadvantages:
• Excellentefciencyandlowleakagelossesreducingyourelectricityconsumption
• Highisolationwhichprotectstheelectronicsfromnoisypowerlines
• LowmagneticeldradiationandnoacousticnoiseenablingthecontrollertopassEMCandother
stringentradiationtests
Allinstallationsandtestingmustbedoneonlyafterreadingandunderstandingallinstructionscarefully.
Allwiringsshouldbedoneonlybytrainedtechnicalpersonnel.Failingtofollowinstructionsandthe
safetywarningsmayresultinseriousinjuryand/ordamagetoproperty.
ElsemaPtyLtdshallnotbeliableforanyinjury,damage,cost,expenseoranyclaimwhatsoevertoany
personorpropertywhichmayresultfromimproperuseorinstallationofthisproduct.
Important warning and safety instructions

3www.elsema.com
Part Numbers:
Part Number Description Application
240S1E
The240S1EisenclosedinacompactIP66ratedplastic
enclosure.CaseSize:175x175x75mm
120S1E-120VACversionforinternationalmarketswith
120VACVoltage
LightCommercialDoors,Industrial
RollerShutters,SectionalDoors,
GarageDoors,SlidingDoorsand
SwingGates
240S2E
The240S2EisenclosedinaIP66ratedplasticenclosurewith
UP/DOWN/STOPexternalpushbuttons.
120S2E-120VACversionforinternationalmarketswith
120VACVoltage
LightCommercialDoors,Industrial
RollerShutters,SectionalDoors,
GarageDoors,SlidingDoorsand
SwingGates
240S2EK
The240S2EKisenclosedinaIP66ratedplasticenclosurewith
UP/DOWN/STOPexternalpushbuttonsandkeyswitchfor
extrasecurityandsafety.
120S2EK-120VACversionforinternationalmarketswith
120VACVoltage
LightCommercialDoors,Industrial
RollerShutters,SectionalDoors,
GarageDoors,SlidingDoorsand
SwingGates
240S1
The240S1controlcardonlywithboardsizeof148x92mm.
120S1-120VACversionforinternationalmarketswith
120VACVoltage
Replacementorupgradecontrollercard
for240VACMotors
240S2
The240S2controlcardonlywithboardsizeof148x120mm
andkeyswitchinput.
120S2-120VACversionforinternationalmarketswith
120VACVoltage
Replacementorupgradecontrollercard
for240VACMotors
Allthesecontrollersaresuitableformotorsupto1.5kW(2.0Hp).
Riskinthegoodspurchasedshallunlessotherwiseagreedinwrittenpasstothebuyerupondeliveryof
thegoods.
Anyguresorestimatesgivenforperformanceofgoodsarebaseduponthecompany’sexperienceand
iswhatthecompanyobtainsontests.Thecompanywillnotacceptliabilityforfailuretocomplywith
theguresorestimatesduetothenatureofvariableconditionsaffectingforexampleRadioRemote
Controls.
Pleasekeepthissetupinstructionforfuturereference.

4Controller Card for 240VAC Motors
Block Diagram
240S1

5www.elsema.com
240VAC Supply Supplyconnectiontopowerthe240S1andthemotor
Open MotorOPENdirectionterminal
Close MotorCLOSEdirectionterminal
Neutral Motorneutralterminal
Motor Capacitor Motorcapacitorterminal
Auxiliary Output Usedtoconnectalockorcourtesylight.RelayContacts,CommonandNormallyOpen
Limit Switch Open &
Common
Iflimitswitchesareusedconnectthemtothisterminal.
FactoryDefaultNormallyClosed
Limit Switch Close Iflimitswitchesareusedconnectthemtothisterminal
Push Button Usedtoconnectanexternalpushbuttontooperatethegateordoor.Normallyopeninput.
Open Only Usedtoconnectanexternalpushbuttontoopenthegateordoor.Withthisinputgateordoor
cannotbeclosed.Holdingthisinputwillpreventclosing.NormallyOpeninput.
Close Only Usedtoconnectanexternalpushbuttontoclosethegateordoor.Withthisinputgateordoor
cannotbeopened.Holdingthisinputwillpreventopening.NormallyOpeninput.
Common Commonterminalforanyoftheinputs,includingpushbutton,openonly,closeonly,stop
andpedestrianaccess.
Stop Usedtoconnectanexternalpushbuttontostopthegateordoor.Holdingthisinputwill
preventthegateordoorfromopeningorclosing.NormallyOpeninput.
Pedestrian Access Usedtoconnectanexternalpushbuttontoopengateordoorpartiallyforpedestrianaccess.
NormallyOpeninput.
Photo Electric Beam Usedtoconnectaphotoelectricbeam.FactoryDefaultisNormallyClosedinput.Usercan
changetoNormallyOpen.
DC Output 24VDC/150mA.Usetosupplyaccessories.
(UseElsemaReg12toconvertthisoutputto12VDC)
Slide Switch Usedtoaccessthecontrolcardfeatures.
Input Status LEDs Indicatesinputsstatus.
Tact Switches
TestbuttonforinputsinRUNmodeandusedtoaccessthefeaturesinprogrammode.
A=PushButton
B=OpenOnly
C=CloseOnly
D=Stop
E=PedestrianAccess
Auto Close trimpot UsedtoadjusttheAutoClosetime.
Dip Switch Usedtoaccessthecontrolcardfeatures.
Open, Close LEDs IndicatesOpeningorClosingcycle.
Enter button Usedtochangefeaturesinprogrammingmode.
Receiver UsedtoconnectElsema’sreceiverstooperatethecontrolcardwitharemotecontrol.Use
Elsema’sPentacodeseries.
Antenna Usedtoconnectanexternalantennaforthepluginreceiver.
Buzzer Indicatesthatchangeoffeatureswassuccessful.
Fuse Slowblow5Ampsfuse.Replacefusewithaslowblow10Ampsifusingamotorlargerthan
1.0kW(1.3HP).

6Controller Card for 240VAC Motors
Relay
A B C D
1
8
ON
27
6
54
3
RUN
Prog1
Prog2
E
FUSE
Open
Close
Normally Closed
User can change to
Normally Open
240Volts
AC Supply
Normally Closed
User can change
Neutral
Motor
Capacitor
Open Limit
Close Limit
Common
Push Button
Open Only
Close Only
Stop
Common
PED Access
Photo Beam
Common
Active
Neutral
Open
Close
M
Motor
Capacitor
Output C
Output NO
DC Output +
DC Output -
Manual
Auto
Common
Key Switch
Input
Earth
R
e
c
e
i
v
e
r
AntennaAntenna
Shield
148mm
120mm
Block Diagram
240S2

7www.elsema.com
240VAC Supply Supplyconnectiontopowerthe240S2andthemotor
Open MotorOPENdirectionterminal
Close MotorCLOSEdirectionterminal
Neutral Motorneutralterminal
Motor Capacitor Motorcapacitorterminal
Auxiliary Output Usedtoconnectalockorcourtesylight.RelayContacts,CommonandNormallyOpen
Limit Switch Open &
Common
Iflimitswitchesareusedconnectthemtothisterminal.
FactoryDefaultNormallyClosed
Limit Switch Close Iflimitswitchesareusedconnectthemtothisterminal.
Push Button Usedtoconnectanexternalpushbuttontooperatethegateordoor.Normallyopeninput.
Open Only Usedtoconnectanexternalpushbuttontoopenthegateordoor.Withthisinputgateordoorcannotbe
closed.Holdingthisinputwillpreventclosing.NormallyOpeninput.
Close Only Usedtoconnectanexternalpushbuttontoclosethegateordoor.Withthisinputgateordoorcannotbe
opened.Holdingthisinputwillpreventopening.NormallyOpeninput.
Common Commonterminalforanyoftheinputs,includingpushbutton,openonly,closeonly,stopandpedestrian
access.
Stop Usedtoconnectanexternalpushbuttontostopthegateordoor.Holdingthisinputwillpreventthegateor
doorfromopeningorClosing.NormallyOpeninput.
Pedestrian Access Usedtoconnectanexternalpushbuttontoopengateordoorpartiallyforpedestrianaccess.NormallyOpen
input.
Photo Electric Beam Usedtoconnectaphotoelectricbeam.FactoryDefaultisNormallyClosedinput.Usercanchangeto
NormallyOpen.
DC Output 24VDC/150mA.Usetosupplyaccessories.(UseElsemaReg12toconvertthisoutputto12VDC)
Common CommonterminalforKeySwitch(NCType)
Auto Autoterminalforkeyswitch.Motorwillbecontrolledbyremotecontrol
Manual Manualterminalforkeyswitch.MotorwillbecontrolledbyOpen,CloseandStoppushbuttons.
Tact Switches
TestbuttonforinputsinRUNmodeandusedtoaccessthefeaturesinprogrammode.
A=PushButton
B=OpenOnly
C=CloseOnly
D=Stop
E=PedestrianAccess
Slide Switch Usedtoaccessthecontrolcardfeatures.
Auto Close trimpot UsedtoadjusttheAutoClosetime.
Dip Switch Usedtoaccessthecontrolcardfeatures.
Open, Close LEDs IndicatesOpeningorClosingcycle.
Enter button Usedtochangefeaturesinprogrammingmode.
Receiver UsedtoconnectElsema’sreceiverstooperatethecontrolcardwitharemotecontrol.UseElsema’s
Pentacodeseries.
Antenna Usedtoconnectanexternalantennaforthepluginreceiver.
Buzzer Indicatesthatchangeoffeatureswassuccessful.
Fuse Slowblow5Ampsfuse.Replacefusewithaslowblow10Ampsifusingamotorlargerthan1.0kW
(1.3HP).

8Controller Card for 240VAC Motors
A B C D
87
E
Close
8
Push Button
Open Only
Close Only
Stop
Ped Access
Photo Beam
Normally Open
(NO)
Normally Closed
User can change
Common
Common
+
-
24V DC out
150mA max
Status LED's
Test buttons
Open
Close
Slow Speed or
Force adjustment
240S1
Electrical Wiring
Alwaysswitchoffpowerbeforedoinganywiring.
Makesurethatallthewiringiscompletedandthatthemotorisconnectedtothecontrol
card.Recommended wire strip length should be 10mm for all connections to
the plug in terminal blocks.
Inputs and Outputs Diagram
Thediagrambelowshowstheinputsandoutputsavailable,theirfactorydefaultsettings,statusLED’s
andthetestbuttonforeachinput.
Setup Instructions
DANGER
Mains
voltage

9www.elsema.com
7 8
A B C DE
8
Push Button
Open Only
Close Only
Stop
Ped Access
Photo Beam
Normally Open
(NO)
Normally Closed
User can change
Common
Common
+
-
24V DC out
150mA max
Status LED's
Test buttons
Common
Auto
Manual
3 position Key Switch
NC (Normally Closed)
240S2
Open, Close and Remote Control Inputs
Theopenandcloseinputsarefactorydefaultsettingtooperateaspressandhold.Thismeanstheuser
willneedtokeeppressingtheinputforthegate/doortooperate.
Theremotecontrolinputsarefactorydefaultsettingtooperateaslatching.Thismeanstheuserpresses
theremotebuttononceandthegate/doorwillfullyopenorfullyclose.
Thepressandholdandlatchingfunctionscanbechangedbyfollowingthestepsandtablebelow:
1. Setdipswitch7and8“ON”and1to6“OFF”
2. Setthemodeswitchtoprogrammode1
PTO

10 Controller Card for 240VAC Motors
3. Setdipswitch1,2,3and4asshowninthetablebelow
Dip switch 1 Dip switch 2 Dip switch 3 Dip switch 4
OpenButton On=PressandHold
Off=Latching
CloseButton On=PressandHold
Off=Latching
RemoteButton1
On=PressandHold
(Button1OpenOnly)
Off=Latching
RemoteButton2
On=PressandHold
(Button2CloseOnly)
Off=Latching
4. PresstheEnterbutton.
5. Buzzerwillbeeptoconrmthechangewassuccessful
6. SetalldipswitchesoffandthemodeswitchtoRun.
IftheremotecontrolistobeusedforOpenOnlyandCloseOnlyfunctionthenthedipswitch2should
besetoninnormalrunmode.
Orangetextindicatesfactorydefaultsetting
Stop and Reverse feature for Push Button
and Remote Control on Close Cycle
Thisfeatureisusedtodisableorenablethe
stopandreversefeatureforthepushbuttonand
remotecontrolontheclosingcycle.Factory
defaultisenabled,thereforeonclosingapush
buttonactivationwillstopthegate/doorand
automaticallyopenit.Followthestepsbelowto
disableorenablethisfeature.
1. Setdipswitch5and8to“ON”
2. Setdipswitch1to4and6,7to“OFF”
3. Setthemodeswitchtoprogrammode1.Run
LEDwillturnred
4. Pressbutton“A”todisableStopandReverse
featureorpressbutton“C”toenableStop
andReversefeature.
5. Buzzerwillbeeptoconrmthechangewas
successful
6. Setalldipswitchesto“OFF”andmode
switchtorun
Push Button Open Only
Thisfeaturechangesthefunctionofthepush
buttonto“OpenOnly”.Thepushbuttoninput
willopengate/door,pushbuttoncannotclose
gate/door.Pushbuttoninputwillbethesame
functionasopenonlyinput.Followthesteps
belowtoenableordisablethisfeature.
1. Setdipswitch5and6to“ON”
2. Setdipswitch1to4and7,8“OFF”
3. Setthemodeswitchtoprogrammode1.Run
LEDwillturnred
4. Pressbutton“A”toenablePBopenonlyor
pressbutton“C”todisablePBopenonly.
5. Buzzerwillbeeptoconrmthechangewas
successful
6. Setalldipswitchesto“OFF”andmode
switchtorun
Dieses Handbuch passt für folgende Modelle
6
Inhaltsverzeichnis
Andere Elsema Controller Handbücher