ELSYS.se ELT Lite Bedienungsanleitung

Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Specifications in this document are subject to change without notice.
©Elektroniksystem i Umeå AB 2019

2
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Important safety information
Read this manual before attempting to install the device!
Failure to observe recommendations included in this manual may be
dangerous or cause a violation of the law. The manufacturer, Elektroniksystem i
Umeå AB will not be held responsible for any loss or damage resulting from not
following the instructions of this operating manual.
•The device must not be dismantled or modified in any way.
•The device is not intended to be used as a reference sensor, and
Elektroniksystem i Umeå AB will not be held liable for any damage which
may result from inaccurate readings.
•The battery should be removed from the device if it is not to be used for
an extended period. Otherwise, the battery might leak and damage
the device. Never leave a discharged battery in the battery
compartment.
•The device must never be subjected to shocks or impacts.
•To clean the device, wipe with a soft moistened cloth. Use another soft,
dry cloth to wipe dry. Do not use any detergent or alcohol to clean the
device.
Disposal note in accordance with ElektroG and WEEE Directive
2012/19/EU
The device, as well as all the individual parts, must not be disposed
of with household waste or industrial waste. You are obliged to
dispose of the device at the end of its service life in accordance with
the requirements of ElektroG in order to protect the environment and to reduce
waste through recycling. For additional information and how to carry out
disposal, please contact the certified disposal service providers. The sensors
contain a lithium battery, which must be disposed of separately.

3
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Contents
Description......................................................................................................................................... 5
Main features of ELT Lite .......................................................................................................... 6
Installation.......................................................................................................................................... 7
Installing external sensors ......................................................................................................... 8
External temperature sensor................................................................................................ 8
Analog input 0 –3 or 0 –10 Voltage............................................................................... 8
Powered analog input 0 –10V........................................................................................... 9
Pulse count (Pull up) ............................................................................................................ 9
Pulse count (Pull down) .....................................................................................................10
Pulse count (Pull down) –External pulse.......................................................................10
Pulse count (Pull up) –S0 input ......................................................................................11
4 –20 mA input...................................................................................................................11
Water leak input....................................................................................................................12
Meter (Decagon) sensor input .........................................................................................12
Sensor configuration......................................................................................................................13
NFC Configuration.....................................................................................................................13
Over the air configuration ........................................................................................................14
Application parameters.............................................................................................................14
Sensor behavior..............................................................................................................................14
NFC Read / Write ......................................................................................................................14
Sensor startup ...........................................................................................................................15
Sampling mode / Periodic measurement .............................................................................16
External sensors ........................................................................................................................16
Specifications ..................................................................................................................................17
Sensor payload format .............................................................................................................17

4
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Regulations......................................................................................................................................18
Legal Notices .............................................................................................................................18
Federal Communication Commission Interference Statement..........................................18
Non-modifications Statement .................................................................................................19
Caution ........................................................................................................................................19
Industry Canada Statement.....................................................................................................19
Declaration of conformity ........................................................................................................19

5
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Description
ELT Lite is a universal outdoor device for LoRaWAN® wireless network. It is
enclosed in an IP67 box and is designed to be in extreme conditions. ELT Lite
can measure analog or digital signals. Use it together with electricity meters, flow
meters, analog sensors, moisture sensors and other external sensors. This is a
battery-powered device equipped with NFC (Near Field Communication) and can
easily be configured from a smartphone.
The barcode contains DevEUI and sensor type. This label is located at the back
of your device,
ELT-lite

6
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Main features of ELT Lite
•Compatible with LoRaWAN® specification 1.0.3
•Analog 0 –10 V input
•Digital input
•Pulse counter
•Direct connection to various external sensors and equipment
•Easy installation
•Easy configuration
•IP67 Classified
•Battery-powered
•Long-range communication
•Configurable over NFC
•Configurable over the air
•Ten years of battery life*
•Supported channel plans: US902-928, EU863-870, AS923, AU915-
928, KR920-923, RU864, IN865 & HK923
•CE Approved and RoHS compliant
*Depending on settings and environmental factors

7
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Installation
1. Remove the front lid of the sensor by removing the four screws.
2. Install the battery. The ELT Lite requires one AA battery. The battery
type is 3.6V Lithium Battery (ER14505).
Caution: Using batteries other than the ones provided may result in loss of performance
and battery life, and also damage to the device. Dispose of properly, observing
environmental protection rules.
3. Connect any eventual external sensors.
4. Close the lid and tighten the screws carefully. Make sure that the cable
gland and antenna connection is tightened to prevent ingress of
moisture.
5. Mount the device by using the two holes on the sides.

8
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Installing external sensors
External temperature sensor
Configured for 1-wire interface. Connect a DS18B20 compatible sensor. Select
“Temperature sensor 1 wire” in the application “Sensor Settings”. ELT input is internally
pulled up by 2.2kΩ.
Analog input 0 –3 or 0 –10 Voltage
Input signal between input and ground.
Select “Analog input 0-3V” or ”Analog input 0 – 10V” in the application “Sensor
Settings”. ELT input is internally pulled down.
/ 0-10V
/ 0-10V

9
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Powered analog input 0 –10V
Input signal between input and ground. +3V present at B+ pin.
Select “Analog input” in the application “Sensor Settings”. Select “Eternal startup time”
and configure ON-time for sensor. External startup time is how long the sensor will be
powered before sampling value. ELT input is internally pulled down and the input
impedance is 7.4 kΩ
Pulse count (Pull up)
Input signal between input and ground.
Select “Pulse input (pull up)” in the application “Sensor Settings”. ELT input is internally
pulled up by ~50 k Ω*.

10
Elektroniksystem i Umeå AB Industrivägen 12, 90130 Umeå, Sweden
E-mail: suppo[email protected] ǀWeb: www.elsys.se
Pulse count (Pull down)
Input signal between input and B+.
Select “External startup time” in the application “Sensor Settings” and configure ON-time
for always on that is >1000000ms.
Select “Pulse input(pull down)”. ELT input is internally pulled down by ~50 kΩ*.
Pulse count (Pull down) –External pulse
Input signal between input and GND. Pulse signal from 3 to 12 voltage.
Select “Pulse input (pull down)” in the application “Sensor Settings”. ELT input is
internally pulled down by ~50 kΩ*.
Inhaltsverzeichnis
Beliebte Modem Handbücher anderer Marken

Davicom
Davicom DM562AP Bedienungsanleitung

EpiValley
EpiValley TATA indicom SXC-1080 Bedienungsanleitung

Zte
Zte WiMAX Bedienungsanleitung

Intelimax
Intelimax MA-2060 Bedienungsanleitung

SMC Networks
SMC Networks D3CM1604V Gebrauchs- und Pflegehandbuch

Telstra
Telstra Wi-Fi 4G Advanced Pro X Bedienungsanleitung

US Robotics
US Robotics 3453C Bedienungsanleitung

MaxTech
MaxTech Plug & Play Internal Voice/FAX/Data/SVD... Bedienungsanleitung

Zte
Zte MF823 Bedienungsanleitung

Four-Faith
Four-Faith F1403 Bedienungsanleitung

Sierra Wireless
Sierra Wireless AIRLINK MP595W Bedienungsanleitung

Gemtek
Gemtek WiMAX WIXFBR-103 Bedienungsanleitung