Emulex OneConnect OCe10102 CNA Bedienungsanleitung

OneConnect
OCe10102 CNA
Installation Manual
One Network.
One Company.
P004450-02A Rev. A Connect with Emulex.
TM

Emulex OneConnect OCe10102 CNA Installation Manual Page ii
EMULEX CONFIDENTIAL. Copyright © 2003-2009 Emulex. All rights reserved worldwide. Unpublished work.
No part of this document may be reproduced by any means or translated to any electronic medium without (a) the
prior written consent of Emulex, and (b) the preservation of this notice on all copies and partial copies. Copying,
access, use or distribution requires an applicable written agreement approved by Emulex.
Information furnished by Emulex is believed to be accurate and reliable. However, no responsibility is assumed by
Emulex for its use; or for any infringements of patents or other rights of third parties which may result from its use.
No license is granted by implication or otherwise under any patent, copyright, trade secret or related rights of
Emulex.
Emulex, the Emulex logo, AutoPilot Installer, AutoPilot Manager, BlockGuard, Connectivity Continuum,
Convergenomics, Emulex Connect, Emulex Secure, EZPilot, FibreSpy, HBAnyware, InSpeed, LightPulse,
MultiPulse, OneCommand, OneConnect, One Network. One Company., SBOD, SLI, and VEngine are trademarks of
Emulex. All other brand or product names referenced herein are trademarks or registered trademarks of their
respective companies or organizations.
Emulex provides this documentation "as is" without any warranty of any kind, either expressed or implied, including
but not limited to the implied warranties of merchantability or fitness for a particular purpose. Emulex may make
improvements and changes to the product described in this manual at any time and without any notice. Emulex
assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties that may
result. Periodic changes are made to information contained herein; although these changes will be incorporated into
new editions of this documentation, Emulex disclaims any undertaking to give notice of such changes.
US patent notice is given for one or more of the following: 6226680, 6247060, 6334153, 6389479, 6393487,
6427171, 6427173, 6434620, 6591302, 6658480, 6697868, 6751665, 6757746, 6941386, 6965941, 6687758,
7042898, 7133940, 7124205, 7089326, 6938092, 6996070.
Emulex, 3333 Susan Street
Costa Mesa, CA 92626

Emulex OneConnect OCe10102 CNA Installation Manual Page iii
Table of Contents
Introduction...................................................................................................................................................1
Major Features ................................................................................................................................1
Prerequisites....................................................................................................................................2
Installing the Converged Network Adapter......................................................................................2
Viewing the LEDs ............................................................................................................................7
References...................................................................................................................................................8
Specifications ..................................................................................................................................8
FCC and Regulatory Notices...........................................................................................................9
Declaration of Conformity..............................................................................................................10
Laser Safety Notice.......................................................................................................................12

Emulex OneConnect OCe10102 CNA Installation Manual Page 1
Introduction
This manual describes the Emulex®OneConnect™OCe10102 multi-protocol PCI-Express Converged
Network Adapter (CNA) for 10 Gigabit Enhanced Ethernet (EE) fabric. Emulex CNAs provide both
traditional networking interface card (NIC) and iSCSI functionality and storage networking functionality
as well as Fibre Channel over Ethernet (FCoE) functionality for convergence of Fibre Channel (FC)
traffic onto 10 Gigabit EE fabric.
Emulex CNAs combine two major functional components: a 10 Gigabit networking MAC and an FC IOC
to interface with a unified lossless Ethernet switch. The CNA serves as a common interface for both
storage and IP traffic retaining familiar FC and networking software stacks, OS drivers, and
management. The supported PCIe connector is an x8. Each CNA is compliant to the PCI Express Base
Specification 2.0.
Figure 1: The Emulex OCe10102 CNA
Major Features
• Single 8-lane standard Generation 2, PCIe interface
• Low-profile PCIe form factor PCBA: 6.600 inches by 2.713 inches
• Comes with full height I/O bracket installed for low profile cards
• Optional low profile I/O bracket is included
• Optical 10 GbE network interface LC connectors
• Copper 10 GbE SFP+ direct-attach connectors
• On-board flash memory: 8M bytes for FC controller program storage
• On-board configuration EEPROM to set FCoE or iSCSI modes of operation (Not changeable in
the field)
• Uses standard Emulex SLI drivers
• Interoperates with existing FC SAN infrastructures - switches, arrays, SRM tools (including
Emulex utilities), SAN practices, and so forth
• Unified Ethernet to FC SAN connectivity provided by FCoE switch
• Provides 10 Gb MAC features such as MSI-X support, jumbo frames (9024 bytes) support,
VLAN tagging (802.1Q, PER priority pause / priority flow control), and advanced packet filtering

Emulex OneConnect OCe10102 CNA Installation Manual Page 2
• No host operating system changes are required, that is, NIC and HBA functionality (including
device management, utilities, and so forth) are transparent to the host operating system.
Prerequisites
• PCI Express 2.0 compliant systems: x8 or x16 lane transfer link interface at up to 5 Gb/s per
lane.
CNA Identification
Each CNA is shipped with several numbers clearly marked on the board Including:
• The IEEE Address
• The World Wide Name (wwn)
• The serial number
• The IEEE address is a unique 64-bit identifier that you use when configuring your system. The
FC industry uses the World Wide Name (wwn) derived from the IEEE address for FC
connectivity. If the adapter has two ports, it has two IEEE addresses and two wwns, one for each
port. Use the serial number when communicating with Emulex. Record these numbers before
installation.
Installing the Converged Network Adapter
The Emulex OCe10102 CNAs use removable optical transceivers or copper interface cables.
Preparing the CNA for Installation
1. Turn off the computer and unplug it.
2. Remove the computer case.
3. Follow steps 4–12 to change the bracket if you want the low profile. Otherwise, skip to “Installing
the Adapter” on page 4.
4. To change the bracket, you must first remove the transceiver from its cage assembly.
CAUTION: This is a delicate operation–take care not to damage the transceiver.
The CNA uses different types of transceivers. Figure 2 shows an example of one type of trans-
ceiver with the bail (handle) extended.
Figure 2: A typical optical transceiver
Note: The CNA comes with a standard PCIe bracket installed. A low-profile bracket is
included in the box with the CNA. The low-profile mounting bracket is shorter than the
standard bracket; approximately 3.11 in. (7.9 cm) compared to 4.75 in. (12.06 cm) long.

Emulex OneConnect OCe10102 CNA Installation Manual Page 3
5. To remove the transceiver, pull the bail (handle) out and down to release the latch and gently pull
the transceiver out. Do not force it. After the latch is released, the transceiver slides out easily.
Figure 3 shows one transceiver partly extracted and the other latched in place.
Figure 3: Removing a transceiver
6. Observing Electrostatic Discharge (ESD) precautions, store the transceiver in an ESD-safe place.
7. Remove the mounting bracket screws from the top of the CNA. Figure 4 shows the screws that
attach the bracket.
Figure 4: Removing the Bracket

Emulex OneConnect OCe10102 CNA Installation Manual Page 4
8. Remove the bracket and store it for future use.
9. Align the new mounting bracket tabs with the holes in the CNA.
10. Re-install the screws that attach the CNA to the bracket.
11. Re-install the transceiver by sliding it into the housing. When the latch engages, it clicks.
12. Push the bail back into place.
Installing the Adapter
1. Turn off and unplug the computer.
2. Remove the computer case.
3. Remove the blank panel from an empty PCIe bus slot. See “Preparing the CNA for Installation” on
page 2 to change the brackets if needed. Otherwise, skip to “Attaching Media” on page 4.
4. Insert the CNA into the empty x8 or x16 PCIe bus slot. Press firmly until the adapter is seated.
5. Secure the CNA's mounting bracket to the case with panel screw or clip.
6. Replace the computer case and tighten case screws.
The CNA is now installed in the server and is ready for media attachment.
Attaching Media
Figure 5 shows the CNA and the optical transceivers.
Figure 5: CNA with Optical Transceivers
Note: Be careful not to push the bracket past the transceiver housing's grounding tabs. Make
sure the light emitting diodes (LEDs) are properly aligned with the holes in the bracket.
Note: Place the CNA into an empty PCIe x8 or x16 slot. Make sure that the adapter is in an
appropriate PCIe slot that does not interfere with other components or case to
prevent damage to the CNA.
Note: A CNA does not allow normal data transmission on either 10 Gb optical or copper link
unless it is connected to a compatible optical or copper interface connection (that is,
multimode to multimode).

Emulex OneConnect OCe10102 CNA Installation Manual Page 5
Note: Use SR, DCR multimode fiber, or 1 to 5 meter SFP+ 10GbE copper cable for interface connections to a
network that adheres to the following specifications:
Note: Some CNA models ship without transceivers for use with Direct Attach Copper cables.
CAUTION: Take care not to plug optical cables into cages without transceivers in them.
Table 1. Media Specifications
Fiber Optic Cable Maximum Length Minimum Length Connector
Short Range, LC-LC Multimode
OM3 - 50/125 Duplex 300 meters (984.25 ft) 1 meter LC
Copper Cable Maximum Length Minimum Length Connector
10GbE Direct-Attach Passive-Copper Cable 5 meters (16.4 ft) 1 meter Direct Attach

Emulex OneConnect OCe10102 CNA Installation Manual Page 6
To attach media to the CNA:
1. Connect the optical cable to the LC connectors on the CNA (see figure 6).
Or:
Insert the Direct Attach Copper transceiver into the SFP+ cage on the CNA (see figure 7).
Figure 6: Connecting Fiber Optic Cable
Figure 7: Connecting the Direct Attach Copper cable

Emulex OneConnect OCe10102 CNA Installation Manual Page 7
2. Connect the other end of the cable to a suitable switch such as a Top of Rack (TOR) EE switch.
After the media is connected to the CNA, you are ready to apply power to the computer.
Applying Power
To apply power:
1. Verify that the CNA is securely installed in the computer.
2. Verify that the correct media is attached.
3. Plug in and turn on the computer.
4. Observe the boot banner for Power On Self Test (POST) results.
Viewing the LEDs
Green and amber LEDs can be seen through openings in the CNA's mounting bracket. Each
corresponding LED is summarized below:
Activity: (Green) (Ethernet Link)
Blink = Activity
Off = No activity
Link (Amber)
On (constantly) = Link up
OFF = Link down
Figure 8: CNA LED Indicators
Inhaltsverzeichnis
Beliebte Computerhardware Handbücher anderer Marken

EMC2
EMC2 VNX Series Betriebsanleitung

Panasonic
Panasonic DV0PM20105 Bedienungsanleitung

Mitsubishi Electric
Mitsubishi Electric Q81BD-J61BT11 Bedienungsanleitung

Gigabyte
Gigabyte B660M DS3H AX DDR4 Bedienungsanleitung

Raidon
Raidon iT2300 Bedienungsanleitung

National Instruments
National Instruments PXI-8186 Bedienungsanleitung