Instructions Gas Heater GH0618
6- The heater should be installed on a pillar with suitable height from the land and the installation of the heater on wall pillar is permissible provided that
the services and maintenance facilities are available.
7- The front of the heater should be open for 1 meter. No garment shall be installed against the heater.
8- The system is designed to work in the environments with the temperature of 0 to 35 degrees of centigrade. For higher temperatures, please contact
sale engineering department of Energy Company in 61444.
-The system shall not be installed in bedroom, bath, washroom or storage and/or to supply the combustion air from these places.
-The distance between the heater and curtains and flammable materials shall not be less than 50 cm.
-The system shall not be placed where it can be in the danger of mechanical or physical shocks,unless,there are some protecting pillars available.In the mean-
time, if the place is installed in villa area, to protect children some necessary arrangements, such as pillar, etc. should be observed so that the children cannot
reach the fan.(If it was impossible to install the pillar with the height of 1.5 meters,necessary arrangements shall be observed to protect children from fan).
- The vent on the wall for combustion air, shall be at least one meter far from each horizontal and vertical balances of the vent pipe.
NOTICE!
The heater is able to operate on hermetic style (to supply combustion air from
outdoor) with a coaxial vent pipe and or separate type (with two separate vent
pipes) which is installed based on the environmental conditions and there is
the availability to supply combustion air from inside or outside environment