2
OPTIMIZER ST2 FILTER MANIFOLD
Installation and Use Manual | Entegris, Inc.
INTRODUCTION
—
The Optimizer®ST2 filter manifold is designed for
use with Optimizer point-of-use (POU) liquid filters
to minimize contamination risk when handling filter
cartridges. Using Entegris’ Connectology®technology,
the Optimizer filter quickly connects and seals to the
ST2 manifold, which enables rapid filter change-outs
without tools or draining. By limiting hazardous
chemical handling during installation, the filter mani-
fold speeds up installation and reduces downtime
while also increasing operator safety.
CAUTION: To reduce the safety risk of chemical
leakage, carefully follow these instructions.
SPECIFICATIONS
—
Materials Metal plates Stainless steel
Release tub Polyacetal
Connectors PFA
O-rings on
manifold
OM: Kalrez®
Connections Tube, Flowell®60, Flowell 80EZ
(See part number table for sizes.)
Maximum
operating
conditions
Maximum operating pressure:
0.39 MPa (3.9 bar, 57psi) at 25°C (77°F)
Maximum operating temperature:
40°C (104°F)
ORDERING INFORMATION
—
OPTIMIZER ST2 MANIFOLD
Quantity: 1 each/box
Tube Type (standard size)
Part number Inlet/outlet Vent port
AMVT442K1 12.7 mm (⁄") tube 6.35 mm (⁄")
AMVT332K1 9.53 mm (⁄") tube 6.35 mm (⁄")
AMVT222K1 6.35 mm (⁄") tube 6.35 mm (⁄")
Flowell 60 Elbow Type
AMVXL42KT 12.7 mm (⁄") 6.35 mm (⁄")
AMVXL32KT 9.53 mm (⁄") 6.35 mm (⁄")
AMVXL22KT 6.35 mm (⁄") 6.35 mm (⁄")
Flowell 80EZ Elbow Type
AMVZL42KT 12.7 mm (⁄") 6.35 mm (⁄")
AMVZL32KT 9.53 mm (⁄") 6.35 mm (⁄")
AMVZL22KT 6.35 mm (⁄") 6.35 mm (⁄")
Replacement O-ring
Part number Description
10456J Kalrez O-ring for ST2 manifold
OM version, 10/bag
CAUTION: If higher pipeline tension is expected, it is
recommended to use a double O-ring combination
of the OM manifold and OF filter.