Installation Specification
It is the responsibility of the installer to follow Entrotec’s installation and cable specification as well
as ALL relevant wiring regulations. Failure to comply with Entrotec’s installation and cable
specification may result in erratic operation of equipment and could invalidate any warranty.
Installations must comply with the following applicable standards:
•BS 7671: Requirements for electrical installations. IET Wiring Regulations 18th Edition.
•The Electricity at Work Regulations 1989
•ANSI/TIA-568.0-D: Generic Telecommunications Cabling for Customer Premises.
•ANSI/TIA-568.1-D: Commercial Building Telecommunications Cabling Standard.
IET Wiring Regulations 18th Edition: Regulation 444 (MEASURES AGAINST ELECTROMAGNETIC
DISTURBANCES) imposes requirements for segregation of circuits.
IET Wiring Regulations 18th Edition: Regulation 528 (PROXIMITY TO WIRING SYSTEMS TO OTHER
SERVICES) imposes requirements for segregation of door entry / access control circuits (Band I),
230VAC mains circuits (Band II) and other higher voltage circuits.
IET Wiring Regulations 18th Edition: Regulations 541 and 542 impose requirements for earthing
and bonding conductors. Ensure ALL metalwork is bonded to the buildings earth, this includes Call
Points, exit switches, cabinets and metal conduit. Ring terminals and earth points are provided on
Call Points and cabinets to terminate earth cables, ensure these connections are made.
WARNING - ISOLATION OF ELECTRICAL EQUIPMENT
In compliance with The Electricity at Work Regulations 1989, electrical equipment should be
made dead to prevent danger while work is carried out on or near that equipment. No person
shall be engaged in any work activity on or so near any live conductor.
Warranty and Support
Entrotec systems are renowned for their reliability and have a 2-year warranty on all Entrotec
manufactured products as standard. This warranty does not cover water damage, vandalism,
mains electrical faults, lightning strikes, damage caused by miswiring or cable faults.
Entrotec offer complimentary training courses and telephone support:
01506 886 235 - 8:30am to 5pm Mon-Thurs and 8:30am to 4pm Friday.
technicalsupport@entrotec.co.uk

Contents
3
Contents
1Cable Specification ............................................................................................................4
Typical Configurations.....................................................................................................4
2Overview...........................................................................................................................6
PRO-DPA (Call Point) .......................................................................................................6
3Connections ......................................................................................................................7
4Factory Default Settings.....................................................................................................8
5Provision...........................................................................................................................8
Provisioning One Way Systems (without an Entrotec Connect Server)..........................8
Provisioning Systems with an Entrotec Connect Server ...............................................13
6Configure ........................................................................................................................17
Video and Audio Settings..............................................................................................17
Lock Release Time.........................................................................................................17

Cable Specification
4
1Cable Specification
The cabling system is based on Unshielded Twisted Pair Category 5e (Cat5e) or Category 6 (Cat6).
The cable must be annealed pure copper, meeting or exceeding the requirements defined in the
standard ANSI/TIA 568 C.2.
Failure to comply with this cable specification may result in erratic operation of equipment.
Typical Configurations
1.1.1 One-Way System
The specification below shows the minimum cable requirements, allow for extra cabling if
redundancy is required.
Connection
Cable
A
PSU to Call Point:
2x 1.5mm² multi-stranded flex or singles
or
1x Cat5e or Cat6.
B
PSU to Apartment Station:
2x 1.5mm² multi-stranded flex or singles
or
1x Cat5e or Cat6.
C
Call Point to Apartment Station:
1x Cat5e or Cat6.
FIGURE 1-1 - PRO-KIT-1W

Contents
5
1.1.2 ePRO Door Entry System with Entrotec Connect Server
The specification below shows the minimum cable requirements, allow for extra cabling if
redundancy is required.
Connection
Cable
A
Door controller with PSU to
each Call Point:
2x Cat5e or Cat6.
B
Lock Relay to locks:
2x 1.5mm² multi-stranded flex or singles (route through
any exit/fire switch or break glass for fail safe operation).
C
Lock Relay to exit switch:
1 Pair UTP (2 cores), Cat5e or Cat6.
D
Lock Relay to fire switch:
1 Pair UTP (2 cores), Cat5e or Cat6.
FIGURE 1-2
NOTE
Refer to the PRO-DC (Door Controller) Installation Guide for Lock and Exit Switch connections.

Overview
6
2Overview
PRO-DPA (Call Point)
2.1.1 Front View
FIGURE 2-1
Microphone
Panel Camera
Call Button
Speaker
2.1.2 Back View
FIGURE 2-2
Tamper Switch
Network, Power and Data
Connections
A
B
C
D
A
B
A
B
C
D
A
B

Connections
7
3Connections
FIGURE 3-1
Connection
Cable Type
Detail
RS485 to Door Controller
1x Cat5e or Cat6
1 Pair UTP - RS485A+RS485B (1+2)
12VDC from Door Controller /
PSU
1 Pair UTP - 12v (Red)
2 Pair UTP - 0v (Black)
Ethernet to Door Controller
1x Cat5e or Cat6
RJ45 - T568B
FIGURE 3-2 - T568B
A
B
Up to 90M
A
B

Factory Default Settings
8
4Factory Default Settings
Setting
Default
IP Address
192.168.1.108
Subnet
255.255.0.0
Gateway
192.168.1.1
Block No.
0
Door No.
8001
5Provision
NOTE ON ENTROTEC CONNECT SERVER
For one-way systems where no PRO-ECS will be fitted, use section 5.1.
For systems where a PRO-ECS is fitted use section 5.2.
Provisioning One Way Systems (without an Entrotec Connect Server)
For one-way systems without an Entrotec Connect Sever, the Call Point can be connected to an
apartment station adopting a peer-to-peer (P2P) network connection. The system configuration is
performed at the PRO-AS7 during initialisation.
5.1.1 Quick Configuration
Connect the PRO-DPA to the PRO-AS7 and power them on. Follow the steps below to initialise the
devices and configure a one-way system:
i. Tap One Way on the PRO-AS7 on the first initialisation screen, then tap OK.
(This operation will update the IP address of the apartment station to 192.168.1.155).
FIGURE 5-1

Provision
9
ii. Enter and confirm the password. The Email address is used for password recovery (default:
support@entrotec.co.uk). Tap OK.
FIGURE 5-2
iii. A list of the devices connected to the network will be displayed. VTO references to PRO-
DPA, Local identifies the apartment station you are operating. Select the VTO in the list by
tapping on it, then start the initialisation process by tapping Initialise.
FIGURE 5-3

Provision
10
iv. Enter and confirm the password for the PRO-DPA. The Email address is used for password
recovery (default: support@entrotec.co.uk). Tap OK.
FIGURE 5-4
v. The PRO-DPA will now show on the list as Initialised. Tap Next.
FIGURE 5-5