Enviro C Series Bedienungsanleitung

1
INSTRUCTION MANUAL
This Cool Surface System has been tested for compliance to Standards:
ANSI Z21.88 and CSA 2.33.
This Cool Surface System has been approved for use on the ENVIRO C34/44/60/72 Direct
Vent replaces only and must be installed at the time of replace installation.
The following instructions must be followed in conjunction with the replace installation
instructions to comply with the standards and allow safe operation of the installed replace.
Version Française: www.enviro.com/fr.html
C#4001609
Cool Surface System
FRONT VENT
PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
C Series
50-4237

2
The purpose of this optional Cool Surface System, or CSS, is to naturally re-direct the convective heat from
the replace. Using this CSS lowers the temperatures of the front wall for installations where a TV, artwork etc.
1
2
3
4
5
6
General Information
Figure 1: Cool Surface System Front Vent- Parts Diagram
is desired directly above the replace.
The outlet of the CSS can be raised
higher up the front wall, within 4” of the
room’s ceiling. The CSS must be vented
directly into room where the appliance
is installed. If using the maximum facing
material thickness you will not be able to
install a surround. A maximum total of 1”
facing material (1/2” on top of cool wall
layer) is allowed if you are installing a
surround.
Note: You can install the Cool Surface
System without the Combustible Facing
Kit. Doing so requires a non combustible
facing material (see Owner’s Manual for
replace installation instructions).
Note: Dual Convection Fan Kit
(50-3212) may not be used in
conjunction with CSS.
Prior to installation of the CSS make
sure the desired location is large
enough to comply with the combustible
clearances of both the CSS and the
replace (see Owner’s Manual for
replace installation instructions). Refer
to the Framing and ClearanCes section of
this manual for the required installation
dimensions of the CSS.
Please refer to Figure 1 and Figure 2 to
ensure that all CSS parts are accounted
for and have not been damaged.
Item Description Item Description
1 Main Duct Body 4 Outlet Trim Bezel
2Right Stando 5 Bezel Louver
3Left Stando 6 Vent Collars
1
3
2
4
Item Description Item Description
1 C34 Main Panel 3 C60 Extension
2 C44 Extension 4 Trimable Deector
Figure 2: Cool Surface System Combustible Facing Kit - Parts
Diagram
The CSS has been designed to allow for
installations where a vertical run of vent
is required without having to jog the
vent pipe around the CSS. The horizontal
vent shield supplied with the replace is
not required (see Owner’s Manual) when
vertically venting and the vent pipe can
simply be run straight up through the cut
out in the CSS.
vertical vent:

3
Dimensions
25 /”
37 /”
7 /”
20 /”
32 /”
11 /”
9 /”
2 /”
2 /”
/” 2 /”
2”
3 /”
7 /”
Ø5”Vent Collars
9 /”
2 /”
2 /”
42 /”
11 /”
47 /”
35 /”
7 /”
25 /”
Ø5”Vent Collars
3 /”
/” 2 /”
2”
7 /”
Figure 3: 50-4128 C34 Cool Surface System Front Vent - Overall Dimensions
Figure 4: 50-4129 C44 Cool Surface System Front Vent - Overall Dimensions

4
Dimensions
9 /”
2 /”
2 /”
11 /”
58 /”
63 /”
51 /”
7 /”
33 /”
Ø5”Vent Collars
3 /”
/”
2”
2 /”
7 /”
2 /”
2 /”
9 /”
11 /”
70 /”
75 /”
65 /”
7 /”
53”
Ø5”Vent Collars
3 /”
/” 2 /”
2”
7 /”
Figure 5: 50-4130 C60 Cool Surface System Front Vent - Overall Dimensions
Figure 6: 50-4131 C72 Cool Surface System Front Vent - Overall Dimensions

5
36”
26”
9.95”
19”
29”
36”
45.75”
0.49”
2.48”
0.50”
0.50”
0.92”
2”
4.75”
0.50”
Figure 7: Cool Surface System Combustible Facing Kit Dimensions
Dimensions

6
Framing & Clearances
QUALIFIED INSTALLERS ONLY
Refer to Figure 8 & Figure 9 for the minimum allowable framing and rough opening of the CSS.
Figure 8: C34 - CSS Framing & Rough Opening
Framing & rough opening:
CSS Outlet Min. Top and Bottom stando = 2⅝” (6.7 cm) *All C Series*
7 1/2"
(2.5 cm)
45" (114 cm)
37 1/4"
(94.6 cm)
Min.
Height
2 x 4 (On Edge)
2 x 4 (On Edge)
C34
WARNING: CSS MUST NOT discharge outdoors or to any other room, it
MUST vent into the room where the appliance is installed. The CSS is only approved for
discharge into the same room and MUST NOT be installed into a oor or ceiling.
*Steel Stud Required if not using Combustible Facing Kit*

7
7 1/2"
(2.5 cm)
C60 = 63 1/4" (161 cm)
2 x 4 (On Edge)
37 1/4"
(94.6 cm)
Min.
Height
C60 = 71" (180 cm)
C44 = 55" (140 cm)
Steel Stud - C60 & C72 ONLY
Steel Stud - C60 & C72 ONLY
C72 = 83" (211 cm)
46 1/2"
(118 cm)
Min.
Height
C72
C60
C44
C72 = 77 1/4" (196 cm)
C44 = 47 1/4" (120 cm)
Framing & Clearances
QUALIFIED INSTALLERS ONLY
Figure 9: C44/C60/C72 - CSS Framing & Rough Opening
C44/C60/C72
CSS Outlet Min. Top and Bottom stando = 2⅝” (6.7 cm) *All C Series*
*Steel Stud Required if not using Combustible Facing Kit*

8
Framing & Clearances
QUALIFIED INSTALLERS ONLY
5 5
8
" (14.3 cm)
4" (10.2 cm)
2 3
4
" (69.8 cm)
73 1
4
"
(174.9 cm)
Side Brace
Min. Height
20" (50.8 cm)
Min. Depth
39” (99 cm) Min.
Length 5” dia. ex vent
(not supplied)
80” (203 cm)
C34/44/60 Min. Ceiling
Min. Vent
Shown below in Figure 10 are the minimum framing and clearances for the CSS when the replace is
installed with the minimum allowable vent length:
Min. Ceiling Clearance from top of CSS outlet = 4” (10.2 cm)
Min. Ceiling Clearance in wall from top of CSS Body = 5⅝” (14.3 cm)
CSS Body Min. Rear stando = 2¾” (69.8 cm)
Figure 10: CSS - Min. Framing & Clearances
minimum clearances - minimum vent:
82 3/8”
(212 cm)
Side Brace
Min. Height
91” (231 cm)
C72 Min. Ceiling
C34
C44
C60
C72

9
Framing & Clearances
QUALIFIED INSTALLERS ONLY
minimum clearances - recess Framing - minimum vent:
5 5
8
" (14.3 cm)
4" (10.2 cm)
78 3
16
"
(199 cm)
Rear Brace
Min. Height
20" (50.8 cm)
Min. Depth
5”
(12.7 cm)
Maximun Recess Depth
(42.6cm)
1613
16
"
Minimum
Recess
Height
(2.2 cm)
Min Clearence to
Heat Shield
7
8
"
1” (2.6 cm)
Min Clearence From
Flex Duct To Conbustable
Material
30"(76cm)
Tiling Flange
87 5
16
"
(222 cm)
Rear Brace
Min. Height
C72
C60
C44
C34
Shown below are the minimun framing requirements and clearences for the HDK with recess framed above
the replace. Figure 11 shows the miniumun framing requirements for a 30” tall recess. The recess height
is adjustable as long as all minimun dimensions are met.
*IMPORTANT NOTE* - The optional Combustible Facing Kit CANNOT BE USED when a recess is
framed above the replace and non-combustible facing material must be used as outlined in the replaces
Owner’s Manual. If using a mantle, revised clearances CANNOT BE USED and mantle clearances must be
followed as outlined in the replace’s Owner’s Manual.
Figure 11: Minimum Recess Framing
C34/C44/C60 Min. Ceiling Height for 30” Tall Recess = 85 13/16” (218 cm)
C72 Min. Ceiling Height for 30” Tall Recess = 94 13/16” (241 cm)

10
Framing & Clearances
QUALIFIED INSTALLERS ONLY
revised mantel requirements:
1 2 3 4 5 6 7 8 9 10 11 12 13 14
MANTLE HEIGHT
MANTLE DEPTH
Minimum Mantle Clearances
8” MANTLE
4”MANTLE
35”
34”
33”
32”
31”
30”
29”
27”
28”
12” MANTLE
Figure 12: Minimum Mantel Height
Refer to Figure 12 for a combustible mantel installation, measurement is from bottom of the unit to the
bottom of the mantel.
If you are planning on installing a TV above the replace refer to page 13 to see the options available.
Note: Minimum height of mantle if you intend on using a surround is 31”
Andere Handbücher für C Series
1
Dieses Handbuch passt für folgende Modelle
4
Inhaltsverzeichnis
Andere Enviro Kaminzubehör Handbücher
Beliebte Kaminzubehör Handbücher anderer Marken

Bronpi
Bronpi KIT-1 Bedienungsanleitung

Town & Country Fireplaces
Town & Country Fireplaces 22150051 Bedienungsanleitung

Travis Industries
Travis Industries 33 DVI Bedienungsanleitung

Superior
Superior ASD3628-TI Bedienungsanleitung

pleasant hearth
pleasant hearth OFP28WG Bedienungsanleitung

IHP
IHP Astria Series Bedienungsanleitung