Faaborg Rehab Technic charder MS 4900 Bedienungsanleitung

0
MS 4900
Medical Scale
USER MANUAL

1
TABLE OF CONTENTS
PREFACE........................................................................................2
GENERAL INFORMATION..............................................................2
SAFETY INSTRUCTION..................................................................2
ENVIROMENTAL.............................................................................3
CLEANING.......................................................................................3
MAINTENANCE...............................................................................3
WEIGHING OPERATION.................................................................3
WARRANTY-LIABILITY...................................................................4
DISPOSING OF THE SCALE .......................................................... 4
SPECIFICATION.............................................................................. 5
PANEL .............................................................................................7
KEY FUNCTION .............................................................................. 8
LCD DISPLAY SYMBOLS................................................................9
USING SCALE...............................................................................10
USING HOLD FUNCTION ............................................................. 11
USING TARE FUNCTION.............................................................. 12
USING BMI FUNCTION................................................................. 12
SETTING-UP MS4900................................................................... 14
PRINT FUNCTION......................................................................... 15
SCALE ASSEMBLING...................................................................17
USING & ASSEMBLING: HEIGHT ROD -HM200M....................... 18
USING & ASSEMBLING: HEIGHT ROD-HM200D/ 201D/ 201M... 19
INSTRUCTION FOR CHARGING AND CONNECTING ................ 20
ASSEMBLY OF TP2100 PRINTER................................................ 21
INSTRUCTION FOR REPLACNG BATTERIES............................. 22
ERROR MESSAGE........................................................................ 23

2
PREFACE
Thank you for choosing Faaborg Rehab Technic’s product. All
features of this product were designed to state of the art and are
optimized for simple and straightforward use. If you have any queries
or experience any problems not addressed in the operating
instructions, please contact your Faaborg Rehab Technic’s service
partner, or visit us on the Internet at www.faaborg-rehab.dk
GENERAL INFORMATION
We strongly recommend you use this device on flat and hard surface.
Any soft surface, like carpet will cause inaccuracy.
SAFETY INSTRUCTION
B efore putting the device into use, please read with care the
information given in the Operating Instructions. They contain
important instructions for installation, proper use and maintenance of
the device.
The manufacturer shall not be liable for damages arising out of
failure to heed the following instructions:
These batteries should be kept away from small children. If swallowed,
promptly seek medical assistance.
When using electrical components under increased safety
requirements, always comply with the appropriate regulations.
Improper installation will render the warranty null and void.
Ensure the voltage marked on the power supply unit matches your
mains power supply.
This device is designed for use indoors.
Observe the permissible ambient temperatures for use
The device meets the requirements for electromagnetic
compatibility. Do not exceed the maximum values specified in the
applicable standards.

3
ENVIROMENTAL
All batteries contain toxic compounds; disposal of batteries
should be delegated to a competent organization, complying with
the deposit of Poisonous Waste Regulation 1972.
Please do not incinerate batteries.
The optimum operating temperature for the scale is 5℃to +35℃;
although it will operate at higher and lower temperatures the
scales battery life will adversely be affected.
CLEANING
We would recommend using alcohol based wipes or similar when
cleaning the scales.
Please do not use large amounts of water when cleaning the
scales as this will cause damage to the scales electronics, you
should also refrain from using corrosive liquids or high pressure
washers.
Always disconnect the scales from the mains power supply
before cleaning.
MAINTENANCE
The scale does not require any routine maintenance. However,
we recommend checking the scale’s accuracy at regular intervals.
The regularity of these checks is dependent on the level of use
and the state of the scale. If any inaccuracies occur, please
contact your local dealer or Faaborg Rehab service partner.
WEIGHING OPERATION
Before reading detailed instructions on how to use all the weighing
functions that are built into your scale, please read the following
important guidelines:
Always be sure that the display shows `Zero` before use, if it does
not then please press the ZERO key.
The device is designed to detect when a stable weight is
achieved, the indicator will `bleep` twice to indicate a stable

4
weight value, your reading should be taken at this point.
WARRANTY-LIABILITY
If a fault or defect is present on receipt of the unit which is within
Faaborg Rehab’s scope of responsibility, Faaborg Rehab shall
have the right to either repair the fault or supply a replacement
unit. Replaced parts shall be the property of Faaborg Rehab.
Should the fault repairs or replacement delivery not be successful,
the statutory provisions shall be valid. The period of warranty
shall be two years, beginning on the date of purchase. Please
retain your receipt as proof of purchase. Should your scale
require servicing, please contact your dealer or Faaborg Rehab
Customer Service.
No responsibility shall be accepted for damage caused through
any of the following reasons: Unsuitable or improper storage or
use, incorrect installation or commissioning by the owner or third
parties, natural wear, changes or modifications, incorrect or
negligent handling, overuse, chemical, electrochemical or
electrical interference or humidity, unless this is attributable to
negligence on the part of Faaborg Rehab.
If operating, climatic or any other influences lead to a major
change in conditions or material quality, the treaty for perfect unit
functioning shall be rendered null and void. If Faaborg Rehab
provides and individual warranty, this means that the unit supplied
will be free of faults for the length of the warranty period.
DISPOSING OF THE SCALE
This product is not to be treated as regular household waste, but
should be handed into an electrical/electronic equipment
recycling center.
You can obtain further details from your local council, your
municipal waste disposal company or the firm which you
purchased the product.

5
SPECIFICATION
Model
MS 4900
Capacity
300kg
300kg
150kg
100g
200g<200kg>500g
100g<100kg>200g
Accuracy
±150g
±200g<200kg>±
500g
±100g<100kg>±
200g
Weight Unit
kg/lb
kg(OIML approved)
LCD Display
1.2 inch LCD display with 5 and 1/2 digits
Dimension
360(L) X 520(W) X 1020(H) mm
Key
Functions
UNIT , PRINT , ON & OFF / ZERO , HOLD/BMI ,
TARE
Power
Supply
6-AA size batteries
9~15V DC adapter
Operation
Temperature
5℃/ 35℃; 0℃/ 40℃(approval)
Standard
Accessories
Screw x 4 , Adaptor x 1 , RS232 cable x 1 , User
manual x 1
Options
Mechanical Height Measurement HM200M
Mechanical Height Measurement HM201M
Digital Height Measurement HM200D
Digital Height Measurement HM201D

6
Standard Accessories
No.
Accessories
Item
Spec.
Qty.
1
Flat head screw
M6 x 20
4
2
9~15V adaptor
1
3
RS232 cable
WR-8159
1
4
User manual
IN-8426
1

7
PANEL
1. Approval Model
2. Non-Approval Model
ON & OFF / ZERO
without lb unit

8
KEY FUNCTION
Key
Description
To change the weighing unit from kg-lb and lb-kg. For
Approval Model this key has been locked at kg unit.
(OIML)
Data transmission via interface(Print-out the results)
Turn ON/OFF the scale.
To reset the display to 0.0kg display / Zero the scale
(±2% of full capacity)
To hold weighing result on the display / long press for
3 seconds to determine Body Mass Index
Tare un-wanted weight.

9
LCD DISPLAY SYMBOLS
Definitions
Stable symbol: To indicate that the weight is stable..
Minor weight: Weight under zero.
Zero symbol: Weight is at zero point.
Low battery: Battery need to charge or replaced.
Stable symbol
Minor weight
value
Zero symbol
Low Battery
Inhaltsverzeichnis
Andere Faaborg Rehab Technic Skala Handbücher