3 < <<<
1Introduction
The appliance can only be installed by a competent person in accordance with the Gas
Safety. We urgently advise you to read this installation manual properly.
This appliance complies with the Gas Appliance Regulation (EU) 2016/426.
Harmonized standards applied EN 613 2000/A1 2003.
2Safety instructions
The appliance should be placed, connected and annually checked in accordance
with these installation instructions and valid national and local Gas Safety
(Installation and Use) Regulations.
Check whether the data on the registration plate are in agreement with the local
type of domestic gas and pressure.
The fitter is not permitted to change these adjustments or the construction of the
appliance!
Do not place any additional imitation logs or glowing coals on the burner or in the
combustion chamber.
The appliance is designed for atmospheric and heating purposes. This means that
all visible surfaces, including the glass, can become hotter than 100°C. It is
advisable to always install a screen for the fireplace if children, elderly or disabled
people are present in the same room as the fireplace. If vulnerable persons can be
present in the room without supervision, sufficient protection must always be
placed around the fireplace.
Do not use the remote control and / or app outside the room where the fireplace is
located. So you are always aware of possible attendees and the situation around
the fireplace when it is ignited.
Do not place any inflammable materials within a of 0,5m. of the radiation of the
appliance and ventilation grills.
Due to natural air circulation of the appliance, moisture and volatile components
from paint, building materials, floor coverings etc. that haven’t yet set, can be
drawn through the convection system and can be deposited on cold surfaces as
soot. That is why you should not use the appliance shortly after a renovation.
The first time the appliance is switched on, Let the fire run on maximum setting for
several hours so that the lacquer coating will have an opportunity to set and
possible vapours released can be safely removed by ventilation. We advise you to
be outside the room as much as possible during this process!