Fancom VLR.20 Bedienungsanleitung

G N D
F
GNDF

N.B.: The original, authentic version of this manual is the English version produced by Fancom B.V. or one of its
daughter companies (referred to further as Fancom). Any modifications introduced to this manual by third parties
have neither beenchecked nor approved by Fancom. Modifications are taken by Fancom toinclude translations into
languages other than English and the insertion and/or deletion of text and/or illustrations to/from the original
contents. Fancom cannot be held liable for any damages, injury, guarantee claims and other claims relating to this
type of modification, in as far as these modifications result in a content that differs from the original English version
of this manual produced by Fancom. For the latest information about product installation and operation, please
contact the customer service dept. and/or the technical service dept. of the Fancomcompany concerned. In spite of
the care taken when compiling this manual, if you should discover any errors, please inform Fancom B.V. in writing.
Fancom B.V., PO Box 7131, 5980 AC Panningen (the Netherlands).
Copyright © 2017 Fancom B.V.
Panningen (the Netherlands)
All rights reserved. Nothing from this manual may be copied, distributed or translated into other languages, partly or
wholly, without express prior written permission from Fancom. Fancom reserves the right to modify this manual
without notice. Fancom can give no guarantee, neither implicit nor explicit, for this manual. All risks are for the user.
This manual has been compiled with the utmost care. If, however, you should discover an error, please inform
Fancom B.V.
Art.Nr. 35911112
GB170501
Gndf

Gndf
i
g
1. General introduction .................................................................................................................................. 1
1.1 How to use this manual ..................................................................................................................1
1.2 Fancom helpdesk ...........................................................................................................................1
1.3 Safety instructions and warnings....................................................................................................2
2. Possibilities of the VLR.20......................................................................................................................... 3
3. Installing the VLR.20 .................................................................................................................................. 3
3.1 Mounting the VLR.20......................................................................................................................3
3.2 Connecting the VLR.20...................................................................................................................3
3.3 Testing the VLR.20.........................................................................................................................4
4. Using the VLR.20........................................................................................................................................ 5
4.1 Setting the switch and knob............................................................................................................5
5. Adjusting the VLR.20.................................................................................................................................. 6
5.1 Fan without DSR-feedback.............................................................................................................6
5.2 Fan with DSR-feedback..................................................................................................................6
5.3 Lighting...........................................................................................................................................6
6. Technical specifications ............................................................................................................................ 7
7. Connection diagram VLR.20 for heating / light........................................................................................ 8
8. Connection diagram VLR.20 for fan control............................................................................................. 9
9. Electrical diagram VLR.20........................................................................................................................ 10
10. Alarm diagram........................................................................................................................................... 11
10.1 Simple alarm unit.......................................................................................................................... 11
10.2 Multiple alarm unit ........................................................................................................................ 11
11. Appendix: EG declaration of conformity................................................................................................ 12

Gndf
1
g
This manual has been compiled with the utmost care. If, however, you should discover an error, please inform
Fancom B.V..
The following symbols are used in this manual:
Tips and suggestions.
Note providing recommendations and additional information.
Warning indicating damage to the product if you do not follow procedures carefully.
Warning indicating danger to humans or animals.
Electrical shock hazard. Danger to humans and animals.
Example of a practical application of the described functionality.
Calculation example.
For any questions and support, please contact the local Fancom Sales & Service Center.

Gndf
2
g
Before installing and commissioning the VLR.20, read the safety instructions, provisions and conditions carefully.
This paragraph contains a number of general safety instructions. The installation of the device and remedying of any
malfunctions should be performed by acertified electrical installer according to the applicable norms. The guarantee
does not apply if this product is installed in any other way than is indicated by Fancom.
Disconnect power before installation.
Prevent electrostatic discharge (ESD) when working on the VLR.20. Ensure that the workplace is clean
and dry.
Use correct wires as shown in the connection diagrams.
Make all wiring connections and check them before applying power. Incorrect connections can cause
permanent damage.
Make sure that the VLR.20 is well and properly grounded according to the guidelines.
Never place the VLR.20 in a place where the weather has direct influence (not in the sun, not in places
where the temperature can rise sharply etc.).
Inspect the VLR.20 periodically for any damages. Notify your installation technician immediately of any
damages. A damaged VLR.20 is unsafe!
Do not use water or high pressure cleaners for lengthy periods.
It is advisable not to switch off the VLR.20. This could lead to condensation caused by cooling down.

Gndf
3
g
The VLR.20 is a power controller for the control of:
1-phase voltage controllable (triac) fans
Electronically controllable lighting (incandescent lighting and controllable fluorescent lighting)
Heating lamps (phase angle control)
Install the VLR.20 and associated components as follows:
1. Mount the VLR.20 (see page 3)
2. Connect the VLR.20 (see page 3)
3. Test the VLR.20 (see page 4)
When mounting/installing the VLR.20, the following should be observed:
Never mount the VLR.20 in a room where animals are present because of the (manual) control.
Place the VLR.20 at such a height that the manual control can be used.
Mount the VLR.20 on a flat surface.
Make sure that the gland nuts are at the bottom of the VLR.20.
Seal all gland nuts after connection of the VLR.20 to prevent entry of dust, aggressive gases and/or
humidity
The VLR.20 is set as standard as an 10-0Vdc analog control. When this control changes into a 0-10Vdc control,
jumper J3 should be changed; see jumper setting. The manual operation connection should also be changed. This
means that the red (RD) and blue (BL) wire should be changed around.
Fancom advises the following controls with applications:
Application
Analog control
Fan(s)
10-0Vdc
Lighting
10-0Vdc
Heating
0-10Vdc

Gndf
4
g
The VLR.20 has four jumpers with which different settings can be made. The factory setting is for fan(s) with DSR
feedback.
Disconnect the power for the VLR.20 before setting the jumper(s).
Application
Jumper setting
Heat/
vent
SF
10-0V/
0-10V
Vent./Lighting
Fan without DSR feedback
Place with small fan Ø35 and
Ø 40. (Jumper is in small bag
in lid)
preferably
10-0Vdc
V
Fan with DSR feedback*
Do not place
preferably
10-0Vdc
V
Lighting
(incandescent / controllable
fluorescent)
Do not place
preferably
10-0Vdc
L
*
Factory setting
**
Change over the red (RD) and blue (BL) wire on the manual operation connector.
1. Check whether the VLR.20 has been connected correctly.
2. Check whether the VLR.20 works optimally.

Gndf
5
g
In the event of malfunctioning the VLR.20 can be set manually using the switch and knob on the front.
Switch
Knob
Output
AUT
A
controlled voltage
AUT
M
voltage adjustable using knob
MAN
M/A
mains voltage
0
M/A
no activity

Gndf
6
g
1. Switch off the power supply to the end station.
2. Control the jumper positions.
3. Switch on the power supply.
4. Set switch and knob to “aut”.
5. Turn potentiometer P1 on the CMV-board completely counter- clockwise.
6. Turn potentiometer P2 on the CMV-board completely clockwise.
7. Set the knob on the front to "man." and turn until the fan starts running.
8. Using potentiometer P2 adjust the minimum voltage between "U" and "V" so that the fan is barely running. A
Fancom fan is normally 2-wire connected and the voltage between "U" and "V" not set below 60Vac. (With a
3-wire connection , do not set the Fancom fan below 45Vac).
9. Turn the knob on the front to a minimum position (not to "aut."), until the fan stops running.
10. Using potentiometer P1 adjust the minimum voltage between "U" and "V" (for a Fancom fan, not below 55Vac).
If the fan is to stop running at 0% control, do not carry out steps 9 and 10. The fan may only stop running
completely with a 2-wire connection.
1. Switch off the power supply to the end station.
2. Control the jumper positions.
3. Switch on the power supply.
4. Set the switch and knob to “aut”.
5. Turn potentiometer P1 on the CMV-board completely counter-clockwise (and leave it in this position).
6. Turn potentiometer P2 on the CMV-board completely clockwise.
7. Set the knob to "man." and turn until the fan starts running.
8. Using potentiometer P2 adjust the minimum voltage between "U" and "V" (for a Fancom fan, not below
30Vac).
1. Switch off the power supply to the end station.
2. Control the jumper positions.
3. Switch on the power supply.
4. Set the switch and knob to “aut”.
5. Turn potentiometer P1 on the CMV-board completely counter-clockwise.
6. Turn potentiometer P2 on the CMV-board completely clockwise.
7. Set the knob to "man." and turn until the lighting is barely on.
8. Using potentiometer P2 adjust the minimum voltage between "U" and "V" (You determine the minimum lighting
position).

Gndf
7
g
Power supply
Mains voltage
230Vac (-10% +6%)
Mains frequency
50-60Hz
Power consumption ( of VLR.20)
3.5VA
Max. current output
only for US and CA models:
20A
- Weak inductive / ohms
max. 20 FLA
- Motor load
max. 17FLA
Fuse (dimensions 6.3x32mm)
Very Fast Acting 30A - 250V
Power outage relay
Relay de-energizes if the power fails
30Vac/60Vdc - max. 2A
Control
Type
10-0Vdc/0-10Vdc
Input resistance
120k
Manual operation
Knob
for 0-100% if the 10-0Vdc control fails
Switch
for “man-0-aut” (man = directly on mains)
Housing
Plastic housing with screw on lid
IP54
Dimensions (l×w×h)
300×240×140mm (11.8×9.4×5.5 inches)
Weight (unpacked)
2.55kg(5.6lbs)
Ambient climate
Operating temperature range
0C to +40C (32F to 104F)
Storage temperature range
-10C to 50C (14F to 112F)
Relative humidity
< 95%, uncondensed
Fancom advises 2-wire connection of Fancom fans. If the fans are connected parallel, heat production
per fan may increase (causing a shortened working life). Fancom therefore advises not to parallel switch
more than three fans. See connection diagrams.