GB
6
Installation
The panel is supplied separately in a cardbox and
fixed to a wall with mounting brackets. Panel is
possible to install in vertical or horizontal position.
Drill the holes for the brackets according to Figure 4
(horizontal position), or Figure 5 (vertical position).
Dimensions Aare distances between the drilled holes
and dimensions B, Cand Dare minimum distances
of the holes from surrounding objects.
Fasten the brackets with screws into dowels (not
included). The dowels should be selected in respect
of a wall material type and higher weight of panel.
Hang the panel on the mounting brackets with two
upper screws (according to suspension) and fasten
firmly to the brackets with nuts with washer. For
horizontal suspension, nuts are screwed on two
screws of the panel.
Besides the mounting brackets, the panel includes
adjustment rests fastened to the lower screws of the
panel and adjusting the distance between the panel
and the wall. Fig. 3 shows a side view of the panel
suspended on the wall.
Electric Installation
The panel is equipped with a two-core cable.
Power supply — 1/N 230 V / 50 Hz
Colour indication of wires: Phase — brown, Central
(working) conductor — blue.
The power supply cable is connected to the wall
junction box, see Fig. 3. If power supply cable is
damaged, then it may only be replaced by
manufacturer or its service technician or similarly
qualified person in order to prevent dangerous
situation.
fig. 5
fig. 4
Panel Control
The panel control by external room thermostat equipped with a switch is recommended
(e.g. Fenix Therm 100).
The room thermostat maintains set air temperature in a room.
Moreover, the panel is equipped with a limiting thermostat which regulates the panel
surface temperature not to exceed 110 °C.
W1A
)mm(
1B
)mm(
1C
)mm(
1D
)mm(
003062581564022
005064581564022
008066581565022
0001068581565022
0021009581565003
0051009581565004
W2A
)mm(
2B
)mm(
2C
)mm(
2D
)mm(
003062581564022
005062581566022
008063581568022
00010635815601022
00210635625811022
00510635635821022