8167686
2022-02i
[8167688]

Translation of the original instructions
Hirschmann® is a registered trademark of its respective trademark holder in certain countries.

Festo — PDAD — 2022-02i
3
Table of contents
1 About this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 Applicable documents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 Product labelling. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.1 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2 Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.3 Training of qualified personnel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3 Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Product overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.1 Product Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.1.1 Scope of delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.1.2 Not in scope of delivery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.2 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.2.1 Functional principle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
4.3 Structure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.3.1 Main components PDAD-09/-13/-22/-51/-73. . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.3.2 Main components PDAD-100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.3.3 Electronic controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.3.4 Multi-way distributors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.3.5 Drying agent cartridge with integrated dust filter. . . . . . . . . . . . . . . . . . . . . . . 12
4.3.6 Air reservoir. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.3.7 Alarm relay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.3.8 Air gun nozzles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
4.3.9 Display components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.1 Ports for input and output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.2 Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.2.1 Mount micro filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.2.2 Condensate input and condensate output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
5.3 Installing mounting accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
6 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.1 Pneumatic installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.2 Power supply connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
6.3 Connection ALARM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
6.4 EM connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
7 Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
7.1 Setting device for the pressure range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
7.1.1 Commissioning device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
7.1.2 Resetting the electronic controller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
8 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
8.1 Maintenance work. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
8.2 Shut down the device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
8.3 Remove covering and mount. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

4
Festo — PDAD — 2022-02i
8.4 Replacing air gun nozzle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
8.5 Cleaning the air gun nozzle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
8.6 Cleaning the silencer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
9 Malfunctions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
9.1 Diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
9.2 Diagnostics via LED. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
10 Technical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
10.1 Nominal flow rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Festo — PDAD — 2022-02i
About this document
5
1 About this document
1.1 Applicable documents
All available documents for the product è www.festo.com/sp.
Document Product Contents
Assembly instruc-
tions
Service kit PDAD-…-SP12000 Replacing the drying agent cartridges
Tab. 1: Applicable documents
1.2 Product labelling
•Observe the specifications on the product.
The product labelling is divided into the following 2 parts.
Product labelling part 1
The product labelling part 1 is located on the right side of the device. The product labelling part 1
enables the product to be identified.
Product labelling (example) Meaning
PDAD-09-G3/8 Order code
552170 Part number
YYYY-MM YYYY = year of manufacture, MM=month of manufacture
Pxxxxx xxxxx = internal check number
X-X-XXX-KC-XXX-XXX X = symbol of the KC-Mark Certificate (test mark for Korea)
p max: 16 bar Max. input pressure
Tmax: 50 °C Max. ambient temperature
Tmin: 2 °C Min. ambient temperature
V: 4.2 l XX = pressure equipment volume V in litres
Festo SE & Co. KG Manufacturer
DE-73734 Esslingen Manufacturer’s address
Made in xxxxx xxxxx = country of manufacture
Tab. 2: Product labelling part 1 (example)

6
Festo — PDAD — 2022-02i
Safety
Product labelling part 2
The product labelling part 2 is located on the power connection of the device. The product labelling
part 2 contains information on the power connection of the device.
Power connection Product labelling Meaning
Top power connec-
tion (AC)
100 - 240 V AC Voltage range when operating with alternating current
(AC)
~ 50 - 60 Hz Required mains frequency
0.14 A -110 V AC Current consumption when operating with 110 V AC
0.07 A - 230 V AC Current consumption when operating with 230 V AC
Bottom power con-
nection (DC)
12 - 24 V Voltage range when operating with direct current (DC)
0.4 A - 24 V DC Current consumption when operating with 24 V DC
0.8 A - 12 V DC Current consumption when operating with 12 V DC
IP65 Degree of protection in accordance with EN 60529
Tab. 3: Product labelling part 2
Warning symbol Meaning
Attention! Dangerous voltage
Risk of high pressure
Tab. 4: Warning symbol on product labelling part 2
Warnings on the product (de, en) Meaning
Gefahr
Auf korrekte Netzspannung achten. Nur eine einzige Spannungs-
quelle anschliessen.
Danger
Make sure the mains voltage is
correct. Only connect a single
voltage source.
Danger
Ensure correct power source is connected. Connect only one
source.
Tab. 5: Warnings on the product
2Safety
2.1 Safety instructions
–Only use the product in its original condition without unauthorised modifications.
–Only use the product if it is in perfect technical condition.
–Observe the identifications on the product.
–Take into account the ambient conditions at the location of use.
–Before working on the product, switch off the power supply and secure it against being switched on
again.

Festo — PDAD — 2022-02i
Additional information
7
Provide complete pressure reduction.
–For protection of the drying agent cartridges ensure that compressed air is not fed to the dryer if the
power feed is interrupted.
–Protect the device and the mounting components from mechanical vibrations.
–Visually inspect the device regularly for damage. Replace damaged device.
2.2 Intended use
The cold-regenerating adsorption dryer is intended exclusively for drying compressed air under the
specified operating conditions, e.g.:
–Install indoors, protected from the weather.
–Maximum relative humidity 80% at temperatures up to 31 °C, linear rise to 50% at 40 °C.
–Do not use at altitudes above 2000 m.
–Install vertically or horizontally è Tab. 10 Permitted mounting positions.
–The condensate input and the condensate output must be connected è 5.2.2 Condensate input and
condensate output.
2.3 Training of qualified personnel
Installation, commissioning, maintenance and disassembly only by qualified personnel.
The qualified personnel must be familiar with the installation of electrical and pneumatic control
systems.
3 Additional information
–Contact the regional Festo contact if you have technical problems.è www.festo.com.
–Accessories and spare parts è www.festo.com/catalogue.

8
Festo — PDAD — 2022-02i
Product overview
4 Product overview
4.1 Product Range Overview
4.1.1 Scope of delivery
Scope of delivery
Micro filter MS6-LFM Connecting kit AC power supply socket
(black)
Adsorption dryer PDAD Tubing PDAD operating
instructions
DC power supply
socket (grey)
Tab. 6: Scope of delivery PDAD
The dryer is supplied in protective packaging.
4.1.2 Not in scope of delivery
Accessories
Type Service kit with drying agent cartridges, O-
rings, reset disc and instruction manual
Air gun nozzle set with 3 nozzles
(PDAD-100: 6 air gun nozzles)
PDAD-09 PDAD-09-SP-12000 ADNA-PDAD-09
PDAD-13 PDAD-13-SP-12000 ADNA-PDAD-13
PDAD-22 PDAD-22-SP-12000 ADNA-PDAD-22
PDAD-51 PDAD-51-SP-12000 ADNA-PDAD-51
PDAD-73 PDAD-73-SP-12000 ADNA-PDAD-73
PDAD-100 PDAD-100-SP-12000 ADNA-PDAD-100
Tab. 7: PDAD accessories
Up-to-date information on the accessories è www.festo.com/catalogue.

Festo — PDAD — 2022-02i
Product overview
9
4.2 Function
4.2.1 Functional principle
The operation of the dryer is intended to ensure a uniform, uninterrupted supply of compressed air of
the required specification.
The function is implemented with 2 or 4 air reservoirs that operate in alternating operating cycles.
While air is being dried in one air reservoir or pair of air reservoirs, the drying agent can regenerate in
the other air reservoir or pair of air reservoirs.
The air flow is routed through the drying agent cartridge of an air reservoir. This extracts moisture from
the air flow. A small amount of the dry air is supplied to the other air reservoir as purge air. The purge
air flows through the drying agent cartridge, escapes into the environment via a drain valve and thus
regenerates the drying agent.
The regeneration cycle lasts 120 s. The associated drain valve is then closed. As a result, the regener-
ated air reservoir with purge air is brought to system pressure and can switch to the operating cycle.
After a further 50 s, the regeneration cycle of the other air reservoir is started at the start of the new
operating cycle.

10
Festo — PDAD — 2022-02i
Product overview
4.3 Structure
4.3.1 Main components PDAD-09/-13/-22/-51/-73
1
2
3
4
5
678
9
10
11
12
13
14 15 16 17
Fig. 1: Design PDAD-09/-13/-22/-51/-73
1
Retaining screw for air reservoir
2
Screw for container seal
3
Air reservoir seal
4
Air reservoir
5
Drying agent cartridge
6
Lower valve block
7
Base plate
8
Covering retaining screw
9
Front covering
10
Silencer
11
Electronic controller
12
Air gun nozzle
13
Upper valve block
14
Multi-way distributors
15
Cover sheet
16
Rear covering
17
Mains connection on the back of the device
Andere Handbücher für PDAD
1
Inhaltsverzeichnis
Andere Festo Trockner Handbücher
Beliebte Trockner Handbücher anderer Marken

Alliance Laundry Systems
Alliance Laundry Systems TMB795C Bedienungsanleitung

Asko
Asko T793C Bedienungsanleitung

Kenmore
Kenmore 8041 - 5.8 cu. Ft. Capacity Electric Dryer Bedienungsanleitung

Frigidaire
Frigidaire CAQE7077KW0 Betriebsanleitung

Bosch
Bosch WTX8HKM9SN Bedienungsanleitung

Sharp
Sharp KD-NHH9S7GW2-PL Bedienungsanleitung