VD510-UV INSTRUCTION MANUAL
-7-
5-1-1) Fasten the valve firmly using mount hole.
(M5*P0.8*D98)
5-1-2) Connect air hose to Air In Port and Controller.
Valve driving pressure is Min 4.0kgf/㎠or more.
5-1-3) Connect fitting for material supply hose to the inner port (BSPT1/8")
Notice
Do not insert fitting too deeply (7 ㎜or more).
5-1-4) Connect a suitable sized needle to the outer port.
5-1-5) Adjust the material pressure (max 5.0kgf/㎠).
When dispensing low viscosity materials (like water, solvent) set material pressure at 0.5kgf/㎠. For
high-viscosity materials, set material pressure at 2.0kgf/㎠.
Increase or decrease pressure as needed.
5-1-6)
At the time of delivery, the scale of shot volume control knob is being initiated
to point 3(½of full stroke). Increase or decrease the number as needed.
Maximum length of stroke is 0.6 ㎜.
(This is corresponding to the amount when shot volume control knob makes 1 round).
Notice
If you make 2 or more revolutions counterclockwise, the tensile strength of spring
is weaker and the valve becomes open state all the time. In this way liquid can
be dispensed.