4 of 59 GH-24, GH-30, GH-45, GH-60 Rev.003
SAFE OPERATION: READ THIS FIRST
Read the entire unit manual before operating.
oWear eye protection when operating this equipment.
oDo not wear jewelry or loose clothing when operating.
oTie hair back before operating machine.
oDo not wear gloves when operating this equipment.
oDo not use damaged, frayed, or deteriorated air hoses or fittings.
oRemoving the tool or weight from the arm will allow the arms to extend rapidly, possibly causing
damage or injury.
oKeep hands clear of the motor chuck and tap when actuating the motor.
oKeep hands free of pinch points on the unit when operating.
oPerform regular maintenance according to the manual, including filling the motor lubricator with
correct oil and greasing the motor gears.
oDo not alter or modify the motor or unit.
oPeriodically inspect for damage, loose hardware or anything irregular.
oRead the FlexArm warranty page before performing any maintenance or repairs.
oDo not exceed the torque or weight limitations for the unit. Doing so will void the warranty and
possibly cause damage or injury.
oIt is imperative that the table or mounting surface be lagged to the floor and secure before installing
the FlexArm Hydraulic Tapping Machine.
oIf the Hydraulic Tapping Machine is going to be lifted with a crane, please call FlexArm for special
instructions.
oFlexArm is not responsible for accident or injury resulting from the misuse of this unit or for use other
than originally designed and intended.
Caution: Always secure the work piece to the table before operating the machine!
This machine is designed for tapping, chamfering, and light reaming of holes.
Safety Standards
oThe oil hoses & fittings can tolerate at least 250 Bar, and have a breakage of pressure above 350 Bar.
The necessity of maximum pressure is from 100 to 120 Bar and the safety valve doesn't permit excess
of 140 Bar, these must be replaced every 10 years or if some malfunction is detected by others with
similar characteristics.
oThe work pieces must be firmly held in place to avoid breakage of taps or of striking the operator. The
operator doesn't have to wear special clothes but protection glasses must be worn.
oWhen the machine is installed, connect it to the ground clamp system before operating.
oFor every adjustment to this machine, the master switch must be disconnected and the work carried
out by electricians.