4
EN
Model version Valve Category Pressure / Gas Destination countries
OUTDOORFIRE W
OUTDOORFIRE B
MERTIK
MAXITROL
GV32
I3B/P
30 mbar, G30
BE, CY, CZ, DK, EE, ES, FR, GB,
GR, HU, IE, IT, LT, NL, NO, PT, RO,
SE, SI, SK,
37 mbar, G30 PL
50 mbar, G30 AT, CH, DE, FR, SK
I3P
30 mbar, G31 FI, NL, RO
37 mbar, G31 BE, CH, CY, CZ, ES, FR, GB, GR,
IE, IT, LT, HR, NL, PL, PT, SI, SK
50 mbar, G31 AT, CH, DE, NL
I3+
30 mbar. G30
BE, CY, CZ, DK, EE, ES, FR, GB,
GR, HU, IE, IT, LT, NL, NO, PT, RO,
SE, SI, SK
37 mbar, G31 BE, CH, CY, CZ, ES, FR, GB, GR,
IE, IT, LT, HR, NL, PL, PT, SI, SK
TECHNICAL SPECIFICATION
Technical specication - manual control - GV32 gas blockw
Unit Appliance category
I3P(30) I3P(37) I3P(50) I3B/P(30) I3B/P(37) I3B/P(50) I3+(30/37)
Destination
countries -FI, NL,
RO
BE, CH,
CZ, ES, FR,
GB, GR,
HR, IE, IT,
LT, NL, PL,
PT, SI, SK
AT, CH,
DE, NL,
SK
BE, CY, DK,
EE, FR, GB,
GR, HU, HR,
IT, LT, NL,
NO, RO, SE,
SI, SK, TR
PL
AT, CH,
DE, FR,
SK
BE,CH, CY,
CZ, ES, FR,
GB, GR, IE,
IT, LT, PT,
SI, SK
Reference gas - G31 G31 G31 G30 G30 G30 G30/G31
Nominal connection
pressure
[mbar]
30 37 50 30 37 50 30/37
Gas pressure per
burner for nominal
(maximum) load
23 23 23 17 17 17
Regulati-
on screw
fully
opened
Gas pressure per
burner for minimum
load
7,5 8,0 6,5 5,5 7,0 5,5 12,0/14,0
Nominal (maxi-
mum) heat load,
according to Hs
8,2 8,2 8,2 8,2 8,2 8,2 8,2
Minimal heat load,
according to Hs 4,9 4,9 4,9 4,9 4,9 4,9 4,9
Gas nozzle [mm]
-
1,65
LPG 1.65
1,65
LPG 1.65
1,65
LPG 1.65
1,65
LPG 1.65
1,65
LPG 1.65
1,65
LPG
1.65
1,65
LPG 1.65