Fri-Jado 9124654 Bedienungsanleitung

Page 1 9124654 Service ManualUltra Sonic Humidier 30001322 2021
- NOTICE -
This service manual is prepared to be used by trained Service Technicians and should not be used by
those not properly qualied. If you have attended a training for this product, you may be qualied to
perform all repair procedures, replacements and adjustments described in this service manual.
The information presented in this document is only valid for standard Custom Convenience Counters,
congurations and is not intended to be all encompassing. The individual specications may dier.
Procedures for which you do not have the necessary tools, instruments or skills should not be performed
by you.
Technical data and specications mentioned in this manual are subject to amendment without prior notice.
Reproduction of this service manual,
without the express written consent of Fri-Jado,
is prohibited.
9124654
Service manual Ultra Sonic Humidier FT-N serie

Page 2 9124654 Service Manual Ultra Sonic Humidier 30001322 2021
Page intentionally left blank

Page 4 9124654 Service Manual Ultra Sonic Humidier 30001322 2021
1. Introduction
1.1 General
This manual is intended for trained technicians, performing repairs on the
Misting system used in the Custom Counter.
The features and controls are being described, along with directions for the
safest and most ecient way to service these units.
All pictograms, symbols and drawings in this manual apply to all available
models.
1.2 Identicationoftheunit
The identication plate can be found on the outside of the machine, and
contains the following data:
• Name of the supplier or the manufacturer
• Model
• Serial number
• Year of construction
• Voltage
• Frequency
• Power consumption

Page 5 9124654 Service ManualUltra Sonic Humidier 30001322 2021
1. Introduction
1.3 Pictograms and symbols
In this manual, the following pictograms and symbols are used:
WARNING
Possible physical injury or serious damage to the unit, if the instructions
are not carefully followed.
WARNING
Risk of Fire.
WARNING
Hazardous electrical voltage.
WARNING
Danger of getting injured by hot surfaces.
SAFETY
Wear safety gloves for installation and dismantling.
SAFETY
Wear eye protection when working on the refrigeration system.
Suggestions and recommendations to simplify indicated actions.
Recycling symbol.
Minimum room oor area.

Page 6 9124654 Service Manual Ultra Sonic Humidier 30001322 2021
1.4 WARNING
● Do not see the light of the UV lamp, It may cause loss of visual power.
● Do not touch any electric circuit during power on especially by wet
hands. It will get electric shock.
● All of electric cable/wire should not damage, processing, pulling or
forcibly bending.
It will cause electric leakage and make re or electric shock.
● All of electric cable/wire should not bind or tie not to cause electric
leakage or ring
● When you have noted smoking or abnormal smell, shut o electric
power source immediately and also o the power switch of the unit.
And manual valve for water supply should be closed. If you keep
running the unit it may cause re or electric shock. Then please report
it to your supplier immediately.
● Do not disassemble the unit except cleaning purpose and also do not
modify the unit. It may cause re or electric shock.
● Do not splash any water on the unit. It may cause short circuit or
electric shock.
● Be careful not to expose the light of UV lamp to the skin too long.
It will cause skin inammation.
● Do not move or shake the unit during the operation. It may cause
electric shock or leakage.
● Do not install or locate the unit where such as unstable or vibrating
places. It may cause fall down the unit and hurt the people around there.
● Do not install or locate the unit where dusty place , sun shine light
exposing directly, high temperature, close to re.
All are very risky for the re of the unit.
1. Introduction

Page 7 9124654 Service ManualUltra Sonic Humidier 30001322 2021
● Keep open through around the electric safety breaker to shut down the
power easily at any emergency cases.
● Use only specied electric power source and no other voltage required.
● Connect Ground without fail.
● Do not use megger tester for the electric circuit check.
It may cause out of order of the electric parts due to the high voltage.
● In case of using the unit at cold weather location, such as lower then
freezing point, all of water pipe lines should be protected from freezing.
Otherwise, pipes may brake due to the freezing.
● The life of the oscillator is about 5,000 hours. The life some times
become shorter because of the using conditions such as water itself,
or cleaning of the scale etc.
Timely replacement of the oscillator required.
● To keep clean inside of the water tank and inside of the blow o
duct hose, Clean up every three days. It may happen, the miscellaneous
germs or bacteria become breeding.
● Cut o the power source when you do the cleaning. Otherwise, It may
have Electric shock.
● Drain o all water of the water tank if you stop the running for a while.
Otherwise, it cause the oensive odor created by some bacteria and it
may aect health.
● Use only clean water for the unit. Other liquid may cause trouble of the
unit and make re or electric shock.
1. Introduction

Page 8 9124654 Service Manual Ultra Sonic Humidier 30001322 2021
2. Installation
2.1 Water Supply
● Use 1/2 inch pipe for water supply. Install a water supply valve and
a strainer (80 mesh or ner) near the humidier unit to remove
impurities in water.
● Connect to the main unit the black pressure-tight tube and half union
that are supplied along with the unit.
Before connecting, be sure to ush out any oil and dirt that may be
inside the pipe work with running water.
● Insert the vinyl hose into the overow port to connect with the drain pipe.
● Leave the black cap on the drain port as is. (It is to be used for draining
at the time of repair or inspection.)
CAUTION:
Install a water shock absorbing device in the water supply line
where water hammering is likely to occur.

Page 9 9124654 Service ManualUltra Sonic Humidier 30001322 2021
Before Operating:
● Be sure the voltage of the power supply before starting the running.
● If you use the unit with humidistat, set the dial of the humidistat at your
expecting level.
Then switch ON the power of the unit.
● Open the valve of the water supply.
Operation:
The running order of the unit after switch on.
● Open the water supply valve and turn the power on to begin water
supply.
● When the water level reaches at the rst specied level, the oat switch
to prevent waterless operation is released and humidication will start.
● When the water level raise to reach the second specied level, the oat
switch for water supply is activated to stop the supply of water. After that,
as the water level lowers due to water consumption for humidication,
the water supply is resumed and this process repeats itself
automatically.
● When the water supply is cut o, the oat switch to prevent waterless
operation becomes activated and the humidication stops automatically.
● If the water pressure becomes abnormally high, it activates the oat
switch for water supply and it may start emitting a tic-tic noise, in which
case turn the valve own to adjust.
● Ensure there is no leak in any part of the pipe work.
CAUTION:
● Do not lift or move the unit while operating.
● Do not lay the unit on its side or upside-down. (This will cause a
waterless operation and damage the ultrasonic oscillator circuit.)
● Do not use a megger tester to check the circuit. (This may damage the
transistors)
3. Operation

Page 10 9124654 Service Manual Ultra Sonic Humidier 30001322 2021
3. Operation
WORKING AND ADJUSTMENT ULTRASONIC HUMIDIFIER
If you switch on the humidier the UV lamp turns on and the water tank
automatically lls up to the rst level with ltered water.
Now the oscillator starts to vibrate and the water molecules are blown out of
the unit, by means of the blower, as a very ne mist and this mist is spread
over the products.
The water tanks is lled up to the second level and then stops.
Now the water level drops to the rst level and is lled up again, and so on.
Points of attention:
- Inside the UV lamp there is a measuring cell.
If UV lamp is worn out the red indication lamp on the transformer is lit.
- UV lamp and oscillator have to be replaced every year.
- Outside on the water tank a clixon is placed as a safety. Set on 55°C.
- Clean the air lter under the water tap.
- Check the position of the adjusting plate slide on top of the humidier.
• length of unit 750 - 2000 mm: rst marking. (Close side)
• Length of unit 2500 mm: rst marking + 2 mm.
• Length of unit 2750 mm: rst marking + 3 mm.
• Lenght of unit 3000 mm: rst marking + 4
Inhaltsverzeichnis