FRONIUS Datalogger Web Bedienungsanleitung

Fronius Datalogger Web
42,0426,0064,EA 012008
Operating Instructions
GB
Data Communication
USA


ud_fr_st_et_01382 012007
Dear Fronius Customer,
Thank you for choosing Fronius - and congratulations on your new, high-quality, high-
tech Fronius product. This introduction should provide you with general information
about the equipment. Please read it carefully to learn about the many great features of
your new Fronius product. This is best way to get the most out of all the advantages that
it has to offer.
Please also note the safety information and the safety precautions for the product
installation location. Following all product instructions will ensure long-lasting quality and
reliability. And these are the essential ingredients for outstanding results.
Introduction

ud_fr_st_et_01382 012007

1
Table of Contents
General ......................................................................................................................................................... 3
General .................................................................................................................................................... 3
Applicable DATCOM Components ........................................................................................................... 3
Prerequisites for Operation ...................................................................................................................... 3
Scope of Supply ....................................................................................................................................... 3
Controls, Connections and ndicators ........................................................................................................... 4
Safety ....................................................................................................................................................... 4
Controls, Connections and ndicators ...................................................................................................... 4
nstalling ‘Fronius Datalogger Web’............................................................................................................... 6
Safety ....................................................................................................................................................... 6
Configuration Examples ........................................................................................................................... 6
Preparations ............................................................................................................................................. 7
nstalling ‘Fronius Datalogger Web’.......................................................................................................... 7
‘Fronius Datalogger Web’ Network Configuration ......................................................................................... 8
General .................................................................................................................................................... 8
Requirements ........................................................................................................................................... 8
‘Fronius Datalogger Web’ Network Configuration .................................................................................... 8
Network Settings for PC / Laptop .................................................................................................................11
General ................................................................................................................................................... 11
Network Settings for PC / Laptop ............................................................................................................ 11
nternet Options for PC / Laptop ............................................................................................................ 13
Connecting to ‘Fronius Datalogger Web’ via LAN and nternet Browser ..................................................... 15
General .................................................................................................................................................. 15
Requirements ......................................................................................................................................... 15
Connecting to ‘Fronius Datalogger Web’ via LAN and nternet Browser ................................................ 15
For the Network Administrator ............................................................................................................... 15
Connecting to ‘Fronius Datalogger Web’ via LAN and ‘Fronius Solar.access’ ............................................ 16
General .................................................................................................................................................. 16
Requirements ......................................................................................................................................... 16
Connecting to ‘Fronius Datalogger Web’ via LAN and ‘Fronius Solar.access’ ....................................... 16
For the Network Administrator ............................................................................................................... 17
Connecting to ‘Fronius Datalogger Web’ via the nternet and ‘Fronius Solar.web’ ...................................... 18
General .................................................................................................................................................. 18
Function overview .................................................................................................................................. 18
Requirements ......................................................................................................................................... 18
Accessing Data from ‘Fronius Datalogger Web’ via the nternet and ‘Fronius Solar.web’ ...................... 19
For the Network Administrator ............................................................................................................... 19
General nformation for the Network Administrator ..................................................................................... 20
General Firewall Settings ....................................................................................................................... 20
Sending Service Messages via a DSL nternet Connection ................................................................... 20
Using ‘Fronius Solar.web’ and Sending Service Messages ................................................................... 20
‘Fronius Datalogger Web’ Views ................................................................................................................. 21
Overview ................................................................................................................................................ 21
Current Total View .................................................................................................................................. 21
Current Comparison View ...................................................................................................................... 21
‘Fronius Datalogger Web’ Settings .............................................................................................................. 23
Overview ................................................................................................................................................ 23
Accessing and Editing Selection Options ............................................................................................... 23
Passwords................................................................................................................................................... 24
General .................................................................................................................................................. 24
Passwords ............................................................................................................................................. 24
User Password ....................................................................................................................................... 24
Administrator Password ......................................................................................................................... 25
Forgot Your Password? .......................................................................................................................... 25

2
Date/Time.................................................................................................................................................... 26
General .................................................................................................................................................. 26
Date/Time............................................................................................................................................... 26
Views ........................................................................................................................................................... 28
General .................................................................................................................................................. 28
Views...................................................................................................................................................... 28
Default Language ................................................................................................................................... 28
Earnings ................................................................................................................................................. 28
Comparison View ................................................................................................................................... 28
Logging ....................................................................................................................................................... 29
General .................................................................................................................................................. 29
Logging .................................................................................................................................................. 29
Memory Capacity ................................................................................................................................... 29
Calculating Memory Capacity................................................................................................................. 29
Calculation Example .............................................................................................................................. 30
Overwriting Data When Memory is Full .................................................................................................. 30
Network ....................................................................................................................................................... 31
General .................................................................................................................................................. 31
Network .................................................................................................................................................. 31
Solar.web .................................................................................................................................................... 32
General .................................................................................................................................................. 32
Solar Web .............................................................................................................................................. 32
Service Messages ....................................................................................................................................... 33
General .................................................................................................................................................. 33
Service Messages .................................................................................................................................. 33
System nformation ..................................................................................................................................... 35
General .................................................................................................................................................. 35
System nformation ................................................................................................................................ 35
Firmware Update ......................................................................................................................................... 36
General .................................................................................................................................................. 36
Firmware Update .................................................................................................................................... 36
Technical Data ............................................................................................................................................. 37
Technical Data........................................................................................................................................ 37

3
General
General The ‘Fronius Datalogger Web’ is a network-compatible Datalogger. The ‘Fronius Data-
logger Web’ website provides a quick overview of the PV system. The website can be
accessed via a direct connection from the ntranet or with the proper configuration via
the nternet.
The ‘Fronius Datalogger Web’ is also equipped with an easy-to-configure system monito-
ring feature with an automatic alarm. The alarm can be signaled via SMS, e-mail, fax,
relay contact or buzzer.
When connected to ‘Fronius Solar.access,’ current PV system data as well as archived
data can be saved to a PC and analyzed. You can also make settings to all devices in
‘Fronius Solar Net.’
When connected to ‘Fronius Solar.web,’ current PV system data as well as archived data
can be easily accessed via the nternet - no difficult configuration required. Data is sent
automatically from ‘Fronius Datalogger Web’ to ‘Fronius Solar.web.’
Applicable DAT-
COM Compon-
ents
‘Fronius Datalogger Web’ can be used with the following DATCOM components:
- 100 x ‘Fronius G Plus’ or ‘Fronius G’ inverter
- 10 x ‘Fronius Sensor Card’ or ‘Fronius Sensor Box’
- 10 x ‘Fronius Public Display Card’ or ‘Fronius Public Display Box’
- 1 x ‘Fronius nterface Card’ or ‘Fronius nterface Box’
- 200 x ‘Fronius String Control’
Scope of Supply - 1 x ‘Fronius Datalogger Web’ Datalogger with wall bracket
- 1 x ‘Safety’ insert
- 1 x ‘Quick nstallation’ insert
- 1 x Ethernet cable 5 m, blue
- 1 x Solar Net cable 2 m, red
- 2 x Terminating plugs
- 2 x nstallation anchors + screws
- 1 x ‘Fronius Solar.access’ CD
- 1 x Relay plug
- 1 x Relay connector housing
- 1 x Sticker set
Prerequisites for
Operation
The inverter requires a ‘Fronius Com Card’ in order to operate ‘Fronius Datalogger Web.’

4
Controls, Connections and Indicators
WARN NG! ncorrect operation can cause serious injury and damage. The
following documentation should be read and understood in its entirety before
the described functions are carried out:
- These operating instructions
- all operating instructions for the system components, especially the
“Safety nformation”
Safety
Controls, Con-
nections and
ndicators
(1)
(11)(10)(9)(8)(7)(6)(5)(4)(3)
(2)
No. Function
(1) Solar Web connection LED
- lights up green: when there is an existing connection to ‘Fronius Solar.web’
- lights up red: when there is no connection to ‘Fronius Solar.web’ but one is
required
- does not light up: when no connection to ‘Fronius Solar.web’ is required
(2) Supply LED
- lights up green: when there is sufficient power coming from ‘Fronius Solar Net’ -
‘Fronius Datalogger Web’ is operational
- does not light up: when there is no power or not enough power coming from
‘Fronius Solar Net’ - an external power source for ‘Fronius Datalogger Web’ is
required
(3) Relay connection
Equipped as a NCC (normally closed contact) and NOC (normally open contact),
switches when there is an error
(4) Connection LED
- lights up green: when there is an active connection within ‘Fronius Solar Net’
- lights up red: when there is an interrupted connection within ‘Fronius Solar Net’
(5) LED
not assigned
(6) Alarm switch
for switching the alarm function on/off
Alarm off: Alarm function, relay and buzzer deactivated
Alarm on: Alarm function, relay and buzzer activated
when ‘Alarm on’ is selected, the buzzer and relay are briefly activated
as a test of the alarm function
Controls, Connections and Indicators on Fronius Datalogger Web

5
Controls, Con-
nections and
ndicators
(continued)
No. Function
(7) P address switch
used to switch from an assigned P address to a default P address ‘169.254.0.180’
Assigned P: ‘Fronius Datalogger Web’ operates using an assigned P address
(factory setting 192.168.1.180). The P address can be set at the
‘Fronius Datalogger Web’ website
169.254.0.180: ‘Fronius Datalogger Web’ operates using a fixed P address
169.254.0.180
The fixed P address is used for a direct connection to a PC
without having to pre-configure the PC
(8) LAN connection
Ethernet interface colored in blue for connecting an Ethernet cable
(9) External power supply connection
for connecting an external power source when the power within ‘Fronius Solar Net’
is insufficient (e.g. when too many DATCOM components are installed in ‘Fronius
Solar Net’).
mportant! The external power supply unit for the Fronius Datalogger Web must
have a secure disconnect between components supplying mains voltage (SELV or
Class 2 for USA / Canada). The output of the power supply unit may not exceed a
max. of 15 VA / 1.25 A.
f the power supply is sufficient, the Supply LED lights up green (2).
(10) Solar Net N connection
‘Fronius Solar Net’ input colored red for connecting other DATCOM component (e.g.
inverters, sensor cards, etc.)
(11) Solar Net OUT connection
‘Fronius Solar Net’ output colored red for connecting other DATCOM component
(e.g. inverters, sensor cards, etc.)

6
Installing ‘Fronius Datalogger Web’
NOTE nstalling the ‘Fronius Datalogger Web’ Datalogger requires knowledge
of network technology.
WARN NG! Operating the device incorrectly can cause serious injury and
damage. The following documentation should be read and understood in its
entirety before the described functions are carried out:
- these Operating nstructions
- all system component operating instructions including safety instructions
Safety
Configuration
examples
= terminating plug
= Fronius Com Card
Inverter PC / LaptopFronius Datalogger Web
IN OUT
IN
OUT
‘Fronius Datalogger Web’ networks with an inverter and a PC
NOTE When networking several DatCom components, a terminating plug must
be placed on each free N and/or OUT connection of a DatCom component.
= terminating plug
= Fronius Com Card
Inverter 1 Inverter Inverter 3
PC / Laptop
Fronius
Sensor Box
Fronius
Datalogger Web
IN OUT
IN OUT
IN
IN
IN
OUT
OUT
OUT
‘Fronius Datalogger Web’ networks with several inverters, a ‘Fronius Sensor Box’ and a PC
Andere Handbücher für Datalogger Web