Frontgate FHTA80088B Bedienungsanleitung

ASSEMBLY INSTRUCTIONS
Installer: Leave these instructions with consumer.
Consumer: Keep these instructions for future reference.
T
FOR USE WITH 20LB (9KG) LIQUID PROPANE
CYLINDER WITH TYPE 1 CONNECTION OR
FOR USE WITH NATURAL GAS AFTER
CONVERSION KIT IS INSTALLED (MUST BE
PROFESSIONALLY INSTALLED) ALSO THE LP
REGULATOR MUST BE SUPPLIED BY THE
MANUFACTURER.
WARNING
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any otherappliance.
A LP-cylinder not connected for use
shall not be stored in the vicinity of this
or any other appliance.
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. If odor continues, keep away from
the appliance and immediately call
your gas supplier or fire department.
WARNING: For Outdoor Use Only
y,
Do not use with any food product!
WARNING: Improper installation,
adjustment alteration, service or
maintenance can cause injury or property
damage. Read the installation, operating
and maintenance instructions thoroughly
before installing or servicing this
equipment.
This appliance can produce carbon
monoxide which has no odor.
Using it in an enclosed space can kill
you.
Never use this appliance in an enclosed
space such as a camper, tent, car or
home.
DANGER CARBON MONOXIDE HAZARD
Questions, Problems, Missing Parts? Before
returning to your retailer, call our customer service
department at 1-800-537-8484, 9 a.m.-5p.m.
EST, Monday - Friday
1
WARNING: USE FACTORY
APPROVED REPLACEMENT
PARTS AND ACCESSORIES
ONLY.USE OF
UNAPPROVED PART OR
ACCESSORIES CAN VOID
THE WARRANTY ON THIS
PRODUCT AND RESULT IN
A HAZARDOUS CONDITION.
PLEASE CONTACT US FOR
INFORMATION REGARDING
REPLACEMNT HOSES,
THERMOCOUPLES,
ELECTRODES, IGNITION
MODULES, LAVA ROCKS,
LOGS, ETC.
CSA Model FHTA80088B & FHTA80087D

TABLE OF CONTENTS
Important Safety Information 3
Information about Propane 4
Specifications 4
Installation 5-9
Lighting Instructions 9
Maintenance 10
Batteries
10
2
163176A CAM - Camellia 163176A PAL- Paloma163176A DEL- Delfina
163176B FLO-Florina 163176B TAL-Talia Medallion
Beige Hexagon Top Faux Wood Hexagon Top Round top
Hexagon Base Round base

IMPORTANT SAFETY INFORMATION
The installation must conform with local codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54; International Fuel Gas Code. ; Natural Gas
and Propane Installation Code, CSA B149.1; or Propane Storage and Handling Code, B149.2,
as applicable.
The appliance and its appliance main gas valve must be disconnected from the gas supply
piping system during any pressure testing of that system at test pressures in excess of 1/2 psi
(3.5kPa).
The appliance must be isolated from the gas supply piping system by closing its equipment
shutoff valve during any pressure testing of the gas supply system at test pressure equal to or
less than 1/2 psi (3.5kPa).
The appliance area must be kept clear and free from combustible materials, gasoline and
other flammable vapors and liquids.
Do not use this appliance if any part has been under water. Immediately call a qualified
service technician to inspect the appliance and to replace any part of the control system and
any gas control which has been under water.
Children and adults should be alerted to the hazards of high surface temperatures and
kept at a safe distance to avoid burns or clothing ignition.
Young children should be carefully supervised when they are anywhere near the
appliance.
Clothing or other flammable material should not be hung from the appliance, or placed
on or near the appliance.
Any screen or guard removed for servicing an appliance must be replaced prior to
operating the appliance.
Installation and repair should be done by a qualified service person. The appliance
should be inspected before use and at least annually by a professional service person.
More frequent cleaning may be required as necessary. It is imperative that the control
compartments, burners and circulating air passageways of the appliance be kept clean.
Do NOT burn solid fuels in this gas fireplace.
CAUTION: The propane gas pressure regulator provided with this appliance must be used.
This regulator is set for an outlet pressure of 11 inches water column.
This outdoor gas appliance is not intended to be installed in or on recreational vehicles and/or
boats.
Before each use of this gas appliance, open the LP (Liquid Propane) Tank Drawer and inspect
the LP Hose. If there is evidence of excessive abrasion or wear, or the hose is cut, it must be
replaced prior to the gas appliance being put into operation. Use only the replacement hose
assembly specified in this manual. Inspect the burner before each use of the appliance. The
burner must be replaced prior to the appliance being put into operation if it is evident that the
burner is damaged. Use only the burner listed in these instructions.
Keep the fuel supply hose away from any heated surfaces.
3

IMPORTANT SAFETY INFORMATION ABOUT
PROPANE (LP) GAS
A self contained LP-gas cylinder for use with this appliance must have a capacity of 20 lbs.
and must be equipped with a Type 1 connector and an OPD (overfill protection device). See
Figure 1.
The LP-gas supply cylinder to be used must be constructed and marked in accordance with
the specification for LP-gas cylinders of the U.S. Department of Transportation (DOT) or the
National Standard of Canada, CAN/CSA-B339, Cylinder, Sphere and Tubes for the
Transportation of Dangerous Goods.
The cylinder supply system must be arranged for vapor withdrawal.
The cylinder used must include a collar to protect the cylinder valve.
This appliance shall be used only outdoors in a well-ventilated space and shall not be
used in a building, garage or any other enclosed space.
When this appliance is not is use, the gas must be turned off at the supply cylinder.
Storage of this appliance indoors is permissible only if the cylinder is disconnected and
removed from the appliance.
Cylinders must be stored outdoors in a well-ventilated area out of the reach of
children .Disconnected cylinders must have threaded valve plugs tightly installed and
must not be stored in a building, garage or any other enclosed areas.
CSA (Canadian Standards Association) certified to ANSI Z21.97•CSA 2.41-2012 “ Outdoor
Decorative Gas Appliances” The gas hose is routed through a “U” bolt to prevent the hose
from coming in contact with the burner. DO NOT remove the hose from the “U” bolt. See
Figure 2.
Figure 1 Figure 2
SPECIFICATIONS
erifwoLrh/utB000,03rh/utB000,55TUPNI
Propane Regulator Pressure 11 in / 2.74 kPa water column
Natural Gas Minimum Inlet
Pressure
7 in / 1.74 kPa water column
Clearances to combustible surfaces Sides 60 in./152cm Top: 72 in. / 183 cm
4
Regulator hose
pointed down

INSTALLATION
1. As it is heavy, carefully unpack all items from the box. Place the tabletop (Separate
pack) in its final position. There must be a minimum of 60 inches of clearance from the
side of the table top to any combustible walls.
2. Place the tabletop on the base. Secure the tabletop to the firepit base using the bolts and
washers that are provided (Separate pack). When you screw the bolts on the round table top,
5
you should choose blue hole to screw the bolts. Hexagon table top, you should choose red hole
to screw the bolts.
Hexagon top use red
color bolt holes to
line up table top .
Round top use blue
color bolt holes to
line up table top.

6
3. Pour the fire ice or lava rock (sold seperately) into the burner pan completely covering
the burner. See
Figure 4.
BURNER PAN
IGNITION WELL
Figure 3
Figure 4

4.Open the tank door, place the tank in the holder and use the chain to hold the tank. Connect
the regulator as shown in Figure 5. Screw the black handle clock-wise to tighten. Turn the
handle counterclock-wise to remove. The hose must point down. Open the control door and
check that the valve is turned all the way clockwise to the “OFF” position. Open the tank
valve. Apply a solution of soapy water to the tank-regulator connection and to the valve-hose
connection to check for leaks. If soap bubbles continue to form, the connection has a leak. If
a leak is found, close the tank valve and tighten all connections.
NEVER USE A FLAME TO CHECK FOR LEAKS.
7

8
Figure 5

LIGHTING INSTRUCTIONS
1. Locate the control and igniter panel. Make
sure the control knob is in the “OFF”
position. See Figure 7. Open the tank door
and open the tank valve all the way.
Figure 7
5. Tighten threaded knob found on tank tray (
Figure 6) so that the LP can’t move from side
to side.
Figure 6
LOW
HIGH
CONTROL KNOB
2. Turn on the control knob to the “LOW”
position, then push in the igniter button.
You will hear a slight cliking sound. Once
The the flame is lit, turn the control knod to
the “ High” position. If the fire does not
light, turn the knob to the “ OFF” position
and wait five (5) minutes, before trying again.
3. To shut down the fire pit, trun the control
knob to the “OFF” position and trun off the
tank valve.
IGNITER BUTTON
9

MAINTENANCE
The flames should look like those in Figure 14. To clean the burner, use a soft brush after the
burner has cooled completely. Never use a vacuum cleaner on the burner. It is recommended
that the fire pit be stored indoors during the winter if it will be subjected to freezing
temperatures. The LP cylinder must be disconnected and removed from the appliance before
the appliance can be stored indoors.
Figure 14
BATTERIES
Make sure the control knob is in the “OFF” position. Unscrew the push button cap on the
ignition module located on the control panel to access the battery compartment. The ignition
module requires one AA size battery. See Figure 15.
10
Figure 15
Please contact one of our Product Specialists for assembly
Specialists are available weekdays 8:00 a.m. to 8:00 p.m. EST
Specialists are available weekdays 8 :00 a.m. to 8:00 p.m. EST or
Saturday 9:30 a.m. to 6:00 p.m.
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere Frontgate Außenkamin Handbücher