Galleon NTS-6001 Merkblatt

NTS-6001 WEB CONFIGURATION
www.galsys.co.uk
galleonsupport.com
TEL: +44 (0) 121 608 4433
FAX: +44 (0) 121 608 4477
NTS-6001 VERSION 11
WEB CONFIGURATION MANUAL

NTS-6001 WEB CONFIGURATION
www.galsys.co.uk
galleonsupport.com
TEL: +44 (0) 121 608 4433
FAX: +44 (0) 121 608 4477
CONTENTS
Introduction……………………………………………………………………………………………………………………………. 4
Web configuration features………………………………………………………………………………………… 4
Web configuration………………………..…………………………………………………………………………………………. 5
Logging-on to the unit……………………………………………………………………………………………………………… 5
Dashboard……………………………………………………………………………………………………………………………… 6
Network tab…………………………………………………………………………………………………………………………… 7
Networking……………………………………………………………………………………………………………… 7
Teaming………………………………………………………………………………………………………………………. 8
Services tab…………………………………………………………………………………………………………………………… 9
Service status………………………………………………………………………………………………………………. 9
SSH……………………………………………………………………………………………………………………………. 10
SNMP………………………………………………………………………………………………………………………… 10
NTP tab………………………………………………………………………………………………………………………………… 11
NTP status…………………………………………………………………………………………………………………. 11
Broadcast…………………………………………………………………………………………………………………… 12
NTP keys……………………………………………………………………………………………………………………. 13
NTP customisation……………………………………………………………………………………………………… 14
Certificate tab………………………………………………………………………………………………………………………… 15
View certificate………………………………………………………………………………………………………… 15
Self-signed certificate……………………………………………………………………………………………………………… 16
SSL certificate…………………………………………………………………………………………………………………………. 17
Logs tab………………………………………………………………………………………………………………………………… 18
Authentication log…………………………………………………………………………………………………… 18
Daemon log………………………………………………………………………………………………………………… 18
Message log…………………………………………………………………………………………………………………19
Radio antenna debug…………………………………………………………………………………………………..19
GPS antenna debug……………………………………………………………………………………………………..20
Network tools tab…………………………………………………………………………………………………………………….21
Network tools –ping……………………………………………………………………………………………………21
Network tools traceroute…………………………………………………………………………………………….21
Network tools –DNS lookup………………………………………………………………………………………..22

NTS-6001 WEB CONFIGURATION
www.galsys.co.uk
galleonsupport.com
TEL: +44 (0) 121 608 4433
FAX: +44 (0) 121 608 4477
Administration tab…………………………………………………………………………………………………………………. 23
Restart………………………………………………………………………………………………………………………. 23
Shutdown………………………………………………………………………………………………………………… 23
Firmware update……………………………………………………………………………………………………… 24
Factory reset……………………………………………………………………………………………………………… 24
Software versions……………………………………………………………………………………………………… 25
Backup………………………………………………………………………………………………………………………. 25
Restore……………………………………………………………………………………………………………………… 26
Custom scripts…………………………………………………………………………………………………………… 27
Change password………………………………………………………………………………………………………. 28
Support……………………………………………………………………………………………………………………… 29
Advanced…………………………………………………………………………………………………………………… 30
Certificates……………………………………………………………………………………………………………. 30-32
Debug………………………………………………………………………………………………………………………….33
GPS antenna debug……………………………………………………………………………………………………. 33
Radio antenna debug…………………………………………………………………………………………………. 34
Additional information…………………………………………………………………………………………………………… 35
NTP customisation……………………………………………………………………………………………………… 35
Configuration commands………………………………………………………………………………………. 35-37
Command options…………………………………………………………………………………………………. 38-39
Auxiliary commands…………………………………………………………………………………………………… 40
Authentication commands…………………………………………………………………………………………..41
NTP keys……………………………………………………………………………………………………………………. 42
SNMP…………………………………………………………………………………………………………………………. 43
System group……………………………………………………………………………………………………………… 43
Interfaces group………………………………………………………………………………………………………… 43
Process monitoring………………………………………………………………………………………………………44
System load monitoring……………………………………………………………………………………………… 44
Technical support………………………………………………………………………………………………………………. 45-46
Support website…………………………………………………………………………………………………… 45-46
Warranty and maintenance……………………………………………………………………………………………………..47

NTS-6001 WEB CONFIGURATION
www.galsys.co.uk
galleonsupport.com
TEL: +44 (0) 121 608 4433
FAX: +44 (0) 121 608 4477
INTRODUCTION
The NTS-6001 is a rack-mount time server based on an embedded Linux operating system and is
designed to serve as a time source for medium to large companies. The rack-mount unit combines
the ability to synchronise time across networks and peer multiple time servers, with the stability of a
dedicated operating system to provide a stable and reliable time source.
WEB CONFIGURATION FEATURES
New, fresh User Interface (UI)
New HTTP daemon with the support for the latest technologies (TLS 1.2, Modern Cipher
Suites, Strict Transport Security)
Failover support
Configuration backups
Custom SSL certificate support
Better SNMP support
More advanced debugging
Performance improvements
Reduced requirement to restart the unit when changing configuration files
Customisation of NTP Authentication Keys and the NTP Configuration
Checks the status of the time source connected to the unit
Checks the overall status of the unit

NTS-6001 WEB CONFIGURATION
www.galsys.co.uk
galleonsupport.com
TEL: +44 (0) 121 608 4433
FAX: +44 (0) 121 608 4477
WEB CONFIGURATION
LOGGING ON TO THE UNIT
Using a web browser, such as Firefox, Chrome or Internet Explorer, navigate to the address of your
unit. The address of your unit will use the following format: ‘https://<IP Addr>’ where <IP Addr> is
the IP Address of your unit as shown on the front LCD.
This is to be entered into the Address Bar of the browser.
Upon navigating to the address of your unit, a login prompt will appear before allowing you access
to the Web Configuration. The Default username and password are ‘administrator’ and ‘password’.
If your network does not support DHCP, then your unit may not appear on the network to start with.
In order to ‘see’ your unit on the network, you may need to set the IP Address manually on the unit
itself. To do this, please see ‘Setting the IP Address Manually’ in the Technical Support section [Page
7].

NTS-6001 WEB CONFIGURATION
www.galsys.co.uk
galleonsupport.com
TEL: +44 (0) 121 608 4433
FAX: +44 (0) 121 608 4477
DASHBOARD
Upon successful login, you will be taken to the Configuration System Homepage. To the left side of
the screen, you’ll find the navigation menu. Use this menu to work through the Status and
Configuration for the unit.
This page displays the current date and time that the unit has been set to and whether or not the
unit is synchronised. It also shows the Network Card configuration and antenna status identifying if
anything isn’t working properly.
Note: It’s highly recommended to make changing your password one of the first things you do when
setting up the unit.
Note: The time displayed is in the UTC time zone. It may not match your wall clock depending on
what time zone you are in and whether daylight savings time is in effect. This does not affect
whether the correct time is shown on client PCs. Clients use the time in UTC from the server plus
information about their local time to calculate the correct local time.

NTS-6001 WEB CONFIGURATION
www.galsys.co.uk
galleonsupport.com
TEL: +44 (0) 121 608 4433
FAX: +44 (0) 121 608 4477
NETWORK TAB
NETWORKING
This shows the current network settings, and allows you to customise them however you wish. To
make them active the settings must be saved to flash and the system rebooted.
Both Ethernet ports on the unit will be displayed. Port 0 (eth0) is the default primary port and Port 1
(eth1) is the secondary port.
By default eth0 will be set to DHCP and will be provided by your network, unless you configured it
manually before connecting to your network (explained in the hardware manual).
You can disable DHCP and set Static settings by changing the IP Address, the Subnet Mask, the
Gateway and Hostname for both IPv4 and IPv6 for each available network port.
You can also configure up to 2 DNS Servers, the Domain Name and appoint a Syslog Server for the
unit.
Note: Changing these settings requires the unit to be rebooted for them to take effect.

NTS-6001 WEB CONFIGURATION
www.galsys.co.uk
galleonsupport.com
TEL: +44 (0) 121 608 4433
FAX: +44 (0) 121 608 4477
TEAMING
This enables you to allow both Network cards to work together as one single card. This provides
more bandwidth for the network and also allows for redundancy.
When this feature is disabled, each network card remains separate and cannot pass data between
each other, keeping both network connections secure.
Modes for the Linux bonding driver (network interface aggregation modes) are supplied in the
configuration file. The behaviour of the single logical bonded interface depends upon its specified
bonding driver mode. The default parameter is balance-rr.
balance-rr - This provides load balancing and fault tolerance.
active-backup - This mode provides fault tolerance.
balance-xor - This selects the same slave for each destination MAC address and provides
load balancing and fault tolerance.
broadcast - This mode is least used (only for specific purpose) and provides only fault
tolerance.
balance-tlb - This is called as adaptive transmit load balancing.
balance-alb - This is Adaptive load balancing mode, this includes balance-tlb + receive load
balancing (rlb) for IPV4 traffic.

NTS-6001 WEB CONFIGURATION
www.galsys.co.uk
galleonsupport.com
TEL: +44 (0) 121 608 4433
FAX: +44 (0) 121 608 4477
SERVICES TAB
SERVICE STATUS
Here you can see the status of any of the services on the Network Time Server.
Note: The clock services may be running, but it does not indicate that the physical clock is either
connected and/or providing a time. The NTP Service will not run until the unit has received an initial
time signal.

NTS-6001 WEB CONFIGURATION
www.galsys.co.uk
galleonsupport.com
TEL: +44 (0) 121 608 4433
FAX: +44 (0) 121 608 4477
SSH
This allows you to toggle SSH on/off to remotely access the unit's operating system, using software
such as PuTTY.
SNMP
This allows for the configuration of SNMP.
Here you can add custom information to the SNMP configuration. The MIBs can be downloaded
from the unit itself or alternatively they can be found on the support site at galleonsupport.com for
your reference.
Inhaltsverzeichnis
Andere Galleon Server Handbücher
Beliebte Server Handbücher anderer Marken

iRobo
iRobo IPC2U Bedienungsanleitung

Nortel
Nortel 1000 Con?guration guide Bedienungsanleitung

Asus
Asus AP7500 Bedienungs- und Wartungshandbuch

Avid Technology
Avid Technology AirSpeed 5000 Bedienungsanleitung

HP
HP Integrity rx2600 Installationsanleitung

Milestone
Milestone Husky IVO 350T Bedienungsanleitung