GE AHS05 Bedienungsanleitung

Write the model and serial
numbers here:
Model #_________________
Serial # _________________
You can find the rating label on the
side of the air conditioner.
GE is a trademark of the General Electric Company. Manufactured under trademark license.
OWNER’S MANUAL
AIR CONDITIONER
ROOM
49-7777 11-17 GEA
SAFETY INFORMATION .........3
USING THE AIR CONDITIONER
Temperature Control ...................4
Air Direction ..........................4
CARE AND CLEANING
Grille and Case ........................5
Air Filter..............................5
Outdoor Coils .........................5
Install Batteries in Remote ..............5
INSTALLATION INSTRUCTIONS
Before you begin ......................6
Electrical Requirements ................6
Parts Included .........................7
Window Requirements .................8
Prepare the Air Conditioner .............8
Install the Air Conditioner............9-10
TROUBLESHOOTING TIPS...... 11
Normal Operating Sounds .............12
CONSUMER SUPPORT
Warranty ............................15
Consumer Support ............Back Cover
AHS05
AHR05

249-7777
THANK YOU FOR MAKING GE APPLIANCES A PART OF YOUR HOME.
Whether you grew up with GE Appliances, or this is your first, we’re happy to have you in the family.
We take pride in the craftsmanship, innovation and design that goes into every GE Appliances
product, and we think you will too. Among other things, registration of your appliance ensures that we
can deliver important product information and warranty details when you need them.
Register your GE appliance now online. Helpful websites and phone numbers are available in the
Consumer Support section of this Owner’s Manual. You may also mail in the pre-printed registration
card included in the packing material.

49-7777 3
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
SAFETY INFORMATION
For your safety, the information in this manual must be followed to minimize the risk of
fire, electric shock or personal injury.
Ŷ8VHWKLVDSSOLDQFHRQO\IRULWVLQWHQGHGSXUSRVHDV
described in this Owner’s Manual.
ŶThis air conditioner must be properly installed in accordance
with the Installation Instructions before it is used.
ŶNever unplug your air conditioner by pulling on the
power cord. Always grip plug firmly and pull straight
out from the receptacle.
ŶReplace immediately all electric service cords that
have become frayed or otherwise damaged. A
damaged power supply cord must be replaced with a
new power supply cord obtained from the manufacturer
and not repaired. Do not use a cord that shows cracks
or abrasion damage along its length or at either the
plug or connector end.
ŶTurn the unit OFF and unplug your air conditioner
before cleaning.
ŶGE Appliances does not support any servicing of the
air conditioner. We strongly recommend that you do
not attempt to service the air conditioner yourself.
ŶFor your safety…do not store or use combustible
materials, gasoline or other flammable vapors or
liquids in the vicinity of this or any other appliance.
ŶAll air conditioners contain refrigerants, which under federal
law must be removed prior to product disposal. If you are
getting rid of an old product with refrigerants, check with
the company handling disposal about what to do.
ŶIf the receptacle does not match the plug, the receptacle
must be changed out by a qualified electrician.
ŶThese R410A air conditioning systems require
contractors and technicians to use tools, equipment
and safety standards approved for use with this
refrigerant. DO NOT use equipment certified for R22
refrigerant only.
WARNING USE OF EXTENSION CORDS
RISK OF FIRE. Could cause serious injury or death.
Ŷ'2127XVHDQH[WHQVLRQFRUGZLWKWKLV:LQGRZ$LU
Conditioner.
Ŷ'2127XVHVXUJHSURWHFWRUVRUPXOWLRXWOHWDGDSWRUV
with this Window Air Conditioner.
HOW TO CONNECT ELECTRICITY
Do not, under any circumstances, cut or remove the third
(ground) prong from the power cord. For personal safety,
this appliance must be properly grounded.
DO NOT use an adapter plug with this appliance.
The power cord of this appliance is equipped with a
3-prong (grounding) plug which mates with a standard
3-prong (grounding) wall outlet to minimize the possibility
of electric shock hazard from this appliance.
Power cord includes a current interrupter device. A test
and reset button is provided on the plug case. The device
should be tested on a periodic basis by first pressing the
TEST button and then the RESET button while plugged
into the outlet. If the TEST button does not trip or if the
RESET button will not stay engaged, discontinue use of the
air conditioner and contact a qualified service technician.
Have the wall outlet and circuit checked by a qualified
electrician to make sure the outlet is properly grounded.
Where a 2-prong wall outlet is encountered, it is your
personal responsibility and obligation to have it replaced
with a properly grounded 3-prong wall outlet.
The air conditioner should always be plugged into its
own individual electrical outlet which has a voltage rating
that matches the rating plate.
This provides the best performance and also prevents
overloading house wiring circuits which could cause a
fire hazard from overheated wires.
See the Installation Instructions, Electrical
Requirements section for specific electrical connection
requirements.
WARNING
READ AND SAVE THESE INSTRUCTIONS

449-7777
USING THE AIR CONDITIONER
Controls
Controls
1. Temperature Control
Setting determines how much cooling is provided.
Max Cool - 10 provides the most cooling and Min
Cool - 1 provides the least.
Fan Only turns off the cooling function.
NOTE: If you move the Temperature control from a
cool setting to a fan setting or power off the unit while
cooling, wait at least 3 minutes before switching back
to a cool setting.
Cooling Descriptions
For Normal Cooling—Select 4-7 on the dial with the
FAN SPEED set to HI or LOW.
For Maximum Cooling—Select 8-10 on the dial with
the FAN SPEED set to HI.
For Quieter and Nighttime Cooling—Select 1-4 on
the dial with the FAN SPEED set to LOW.
2. Fan Speed
The fan speed button can be set on HI or LOW. In
both cooling mode and fan only mode.
3. Power
Turns the unit on or off.
Features and appearance will vary.
FAN ONLY
MIN
COOL
MAX
COOL
Wait 3 Minutes
Before Restarting
SPEED
HI LOW
POWER
ON OFF
1
2
3
4
56
7
8
9
10
Air Conditioner Controls
Air Direction
8VHWKHOHYHUWRDGMXVWWKHDLUGLUHFWLRQOHIWWRULJKW

49-7777 5
Care and Cleaning
CARE AND CLEANING
Grille and Case
Turn the air conditioner off and remove the plug from the
wall outlet before cleaning.
To clean, use water and a mild detergent. Do not use
bleach or abrasives.
Air Filter
The air filter behind the front grille should be checked
and cleaned at least every 30 days or more often if
necessary.
To remove:
Slide the filter from the left side of the unit. Remove the
filter.
Clean the filter with warm, soapy water. Rinse and let the
filter dry before replacing it. Do not clean the filter in a
dishwasher.
CAUTION
DO NOT operate the air conditioner
without a filter because dirt and lint will clog it and reduce
performance.
Outdoor Coils
The coils on the outdoor side of the air conditioner should
be checked regularly. If they are clogged with dirt or soot,
they may be professionally cleaned.
Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for freezing
outdoor conditions. It must not be used when the outdoor
temperature is below freezing (32°F).

649-7777
INSTALLATION INSTRUCTIONS
BEFORE YOU BEGIN
Read these instructions completely and carefully.
• IMPORTANT – Save these
instructions for local inspector’s use.
• IMPORTANT – Observe all
governing codes and ordinances.
• Note to Installer – Be sure to leave these
instructions with the Consumer.
• Note to Consumer – Keep these instructions for
future reference.
• Skill level – Installation of this appliance requires
basic mechanical skills.
• Completion time ±$SSUR[LPDWHO\KRXU
• We recommend that two people install
this product.
• Proper installation is the responsibility
of the installer.
• Product failure due to improper installation is not
covered under the Warranty.
<RX0867XVHDOOVXSSOLHGSDUWVDQGXVHSURSHU
installation procedures as described in these
instructions when installing this air conditioner.
Questions? Call 800.GE.CARES (800.432.2737) or Visit our Website at: GEAppliances.com
These models require a 115/120-volt AC,
60-Hz grounded outlet protected with a
15-amp time-delay fuse or circuit breaker.
The 3-prong grounding plug minimizes the possibility
of electric shock hazard. If the wall outlet you plan to
use is only a 2-prong outlet, it is your responsibility to
have it replaced with a properly grounded 3-prong wall
outlet.
CAUTION
Do not, under any circumstances, cut or remove the
third (ground) prong from the power cord.
Do not change the plug on the power cord of this air
conditioner.
Aluminum house wiring may present special
problems—consult a qualified electrician.
ELECTRICAL
REQUIREMENTS
Power cord includes a current interrupter device. A
test and reset button is provided on the plug case. The
device should be tested on a periodic basis by first
pressing the TEST button and then the RESET button
while plugged into the outlet. If the TEST button does
not trip or if the RESET button will not stay engaged,
discontinue use of the air conditioner and contact a
qualified service technician.
ELECTRICAL
REQUIREMENTS (CONT)
TOOLS YOU WILL NEED
Phillips head screwdriver
Ruler or tape measurePencil
Level Scissors or knife
Drill and 1/8” drill bit
Installation Instructions

49-7777 7
Installation Instructions
INSTALLATION INSTRUCTIONS
Side Curtain
Frame
Type B (9)
Foam top window
gasket
Side
Curtain (2)
Top mounting rail
Air
conditioner
Window locking
bracket (1)
Side Brackets (2)
PARTS INCLUDED
(Appearance may vary)
Left Right
Type A (3)

849-7777
Installation Instructions
INSTALLATION INSTRUCTIONS
3. PREPARE THE AIR CONDITIONER
A. Install the top mounting rail with 3 Type A screws
B. Slide the side curtain panels into the side panel
rails.
C. Slide left and right side curtain frames into top
and bottom rails. Make sure that side curtains
snap into side of the frames.
1. WINDOW REQUIREMENTS
• These instructions are for a standard double-hung
window. You will need to modify them for other
types of windows.
• The air conditioner can be installed without the
side curtain panels if needed to fit in a narrow
window. See the window opening dimensions.
• All supporting parts must be secured to firm
wood, masonry or metal.
• The electrical outlet must be within reach of the
power cord.
• Follow the dimensions in the table and
illustration for your model.
2. STORM WINDOW REQUIREMENTS
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will keep
LWIURPGUDLQLQJSURSHUO\7RDGMXVWIRUWKLVDWWDFK
a piece of wood to the sill.
WOOD PIECES
WIDTH: 2Ǝ
LENGTH: Long enough to fit inside the window
frame.
THICKNESS: To determine the thickness, place
DSLHFHRIZRRGRQWKHVLOOWRPDNHLWƎKLJKHU
than the top of the storm window frame or the
vinyl frame.
Attach securely with nails or screws provided by
the installer.
13 3/8”
(With side curtain panels)
21 7/8” - 36”
ƎKLJKHU
than storm
window
frame
Storm window
frame
Wood
Sill
ƎKLJKHU
than vinyl frame
(on some windows)
Vinyl frame
Top Mounting rail
CLICK

49-7777 9
Installation Instructions
INSTALLATION INSTRUCTIONS
4. INSTALL THE AIR CONDITIONER
IN THE WINDOW
A. Measure the width of the window opening and
mark the center line on the inside window sill.
Place the unit in the window. Lower the window
to hold unit in place.
B. Set the air conditioner in the window so that is
centered. Place the air conditioner so that front
edge of the bottom mounting rail is against the
back edge of the sill.
C. Install the side bracket into the unit and into the
window sill using two 1” wood screws provided.
repeate on other side.
Width of window opening
Center line
4. INSTALL THE AIR CONDITIONER
IN THE WINDOW (continues)
D. Bring the window down so that the front edge of
the top mounting is in front of the window. Make
sure that the air conditioner is level or tilting
slightly to the outside.
E. ([WHQGWKHFXUWDLQSDQHOVXQWLOWKH\ILOOWKH
window. Mark the location of the holes in each
FRUQHU8VHWKHGULOODQG´GULOOELWWRGULOOSLORW
KROHV8VHW\SH%VFUHZVWRVHFXUHWKHVLGH
panels in place.
Type B screws

10 49-7777
Installation Instructions
INSTALLATION INSTRUCTIONS
5. INSTALL WINDOW LOCKING
BRACKET AND FOAM TOP
WINDOW GASKET
8VH7\SH%6FUHZWRLQVWDOOWKHZLQGRZORFN
bracket on top of the bottom window.
.
A. CAUTION
To prevent broken glass or
damage to windows, on vinyl
or other similarly constructed
windows, attach the window
locking bracket to the
ZLQGRZVLGHMDPEZLWKRQH
Type B screw.
B. Cut the foam top window gasket to the window
width.
C. Stuff the foam between the glass and the window
to prevent air and insects from getting into the
room.
NOTE: If the gasket supplied does not fit your
window, obtain appropriate material locally to
provide a proper installation seal.
Wood
Vinyl
Dieses Handbuch passt für folgende Modelle
3
Inhaltsverzeichnis
Sprachen:
Andere GE Klimaanlage Handbücher

GE
GE AJEQ10DCD Bedienungsanleitung

GE
GE AEZ18 Bedienungsanleitung

GE
GE AGP07 Betriebsanleitung

GE
GE ASM06 Betriebsanleitung

GE
GE Zoneline 4100 Bedienungsanleitung

GE
GE AGP18 Betriebsanleitung

GE
GE AGV18 Originalbetriebsanleitung

GE
GE AKCQ10A Originalbetriebsanleitung

GE
GE AEQ06 Betriebsanleitung

GE
GE AHD08 Bedienungsanleitung

GE
GE Carry Cool ATM04 Schulungshandbuch

GE
GE AEH24* Betriebsanleitung

GE
GE AHH08 Betriebsanleitung

GE
GE AEZ12 Series Betriebsanleitung

GE
GE AEQ06LN Handbuch

GE
GE AHH06 Betriebsanleitung

GE
GE AJCM08ACG Betriebsanleitung

GE
GE ASW05 Betriebsanleitung

GE
GE AEL18DP Betriebsanleitung

GE
GE APCD07 Bedienungsanleitung