Global M3 SYSTEM Bedienungsanleitung

®
INFECTION CONTROL CONSULTANTS LLC
OPERATING MANUAL
The M3 System® Delivery Module
giccllc.com
Measure Manage Monitor

®
INFECTION CONTROL CONSULTANTS LLC
giccllc.com
PROVIDING A SAFE AND HEALTHY INDOOR ENVIRONMENT

General Safety Guidelines 4
5
6
7
9
12
16
18
20
23
Purpose of Use and Safety
Environmental Safety
Transportation and Storage
Installation
Piping Connections
Priming
Troubleshooting
Maintenance
Warranty
Table of
Contents

The M3 System® Delivery Module4
These operating instructions contain safety
information that, if ignored, can endanger life or
result in serious injury.
Read these instructions carefully before use and
keep them for future reference.
Version: R1
General Safety Guidelines
Operating, installing, or maintaining the unit in any
way that is not covered in this manual could cause
death, serious personal injury, or damage to the
equipment.
This manual uses the following safety message icons:
Danger! Warning!
Indicates a hazardous situation which, if not avoided,
could result in death or serious injury.
Important!
A practice not related to personal injury or additional
information.

5The M3 System® Delivery Module
PURPOSE OF USE AND SAFETY
The M3 System® Delivery Module is intended for
fluid dispersion of Path-Away Anti-Pathogenic
Aerosol Solution® or an alternate approved by GICC.
• Do not use in explosive area
• Do not use with flammable chemicals
• Do not use with radioactive chemicals
• Use only after a proper installation
Before any operation:
• Always read product Material Safety Data Sheet (MSDS)
•Always wear protective clothing
•Always discharge the liquid end before servicing the pump
•This unit shall never be used with hazardous or unknown chemicals
Use the delivery module in accordance with the data and
specifications printed on the label.
Do not modify or use in a manner inconsistent with the provisions of
the operating manual.
Keep the delivery module protected from sun and water. Avoid water
splashes.
In emergencies, the delivery module should be switched o
immediately. Disconnect the power cable from the power supply.
When installing, always observe national regulations.
Manufacturer is not liable for any unauthorized use or misuse of this
product that may cause injury, or damage to persons or materials.
The delivery module must be accessible at all times for both
operating and servicing. Access must not be obstructed in any way.
Adequate measures shall be taken to prevent cross connection of
product with any chemicals.
Pump and accessories must be serviced and repaired by qualified
and authorized personnel only.
Risk of electric shock - This pump is supplied with a grounding
conductor and grounding type attachment plug. To reduce the risk
of electric shock, be certain that it is connected only to properly
grounded, grounding-type receptacle.
CAUTION - This Pump Has Been Evaluated for Use With Path-Away
Anti-Pathogenic Aerosol Solution only.

The M3 System® Delivery Module6
ENVIRONMENTAL SAFETY
Spare parts For spare parts orders or any other communication,
refer to the pump’s label. The serial number can be
used to uniquely identify the Delivery Module..
THIS DELIVERY MODULE IS TESTED AND
CERTIFIED BY UL FOR MATERIALS SAFETY.
Work area
Always keep the delivery module area clean to avoid and/or
discover emissions.
Recycling guidelines
Always recycle according to these guidelines:
• If the unit or parts are accepted by an authorized recycling
company, then follow local recycling laws and regulations
• If the unit or parts are not accepted by an authorized recycling
company, then return them to the nearest representative
Waste and emissions regulations
Observe these safety regulations regarding waste and emissions:
• Dispose appropriately of all waste
• Handle and dispose of the dosed product in compliance with
applicable environmental regulations
• Clean up all spills in accordance with safety and environmental
procedures
• Report all environmental emissions to the appropriate authorities
Label (Example)
Fig. 1. UL label.
*SA6040D85 030621 1209*
Model: SA6040D85
100-120 Vac, 60 Hz, 1.2A, 120 W
Insulaon Class A
Duty Cycle: 6 Seconds
Manufactured Date: xx/xx/20xx
US Patent Pending #62/706,137
CAUTION – This pump has been evaluated for use with Path-Away An-Pathogenic Aerosol Soluon only.
WARNING – Risk of Electric Shock – This Pump Has Not Been Invesgated For Use In Swimming Pool or
Marine Areas. To reduce electric shock, connect only to a properly grounded, grounding type receptacle.
Acceptable For Indoor Use Only.
Nonsubmersible Pump.
UL 60730-1
UL778
CAN/CSA-E60730-1
CSA C22.2 No. 108
Serial Number: xxxxxxxxxxxx
M3 System® Delivery Module
www.m3systemprotecon.com
Global Infecon Control Consultants LLC.
Technology property of GICC LLC

7The M3 System® Delivery Module
TRANSPORTATION AND STORAGE
A non-suitable transportation or storage container can cause
damages.
Use original box to pack the delivery module.
Observe storage conditions for transportation.
Although securely packed, always protect the unit against
humidity and avoid direct contact of chemical agents not
acceptable for use or contact with unit.
Before returning the delivery module to the manufacturer for
repair service, drain the product from pump head and rinse.
Do not trash packaging. Use it to return the delivery module.
Transportation and storage temperature: 10 - 50°C (32 - 122°F)
Humidity 95% relative humidity (not condensed)
Included
features QUANTITY CONTENT M3 SYSTEM
n. 1 Main Unit
n. 1 Back Pressure Regulator
w/Nozzle
n. 1 Axial Foot Filter (PVDF)
n. 1 Injection Valve (PVDF)
m 7.6 Delivery Hose
m 2.4 Suction Hose
m 3.0 Discharge Hose
m 1.8 Power Cable
n. 1 Operating Manual

The M3 System® Delivery Module8
Tab. 1. Capacity
FLOW
Model
M3 4.31 4.69 0.00113 0.249 18 7 101.5 4 x 6 4 x 60.001239
min
cc/h
max
I/h
Min
GPH
Max
GPH
pulse
/
min
Maximum
pressure
bar PSI delivery
(PE)
suction
(PE)
Hosescc per
STROKE
Environment temperature•••••••••••••••••• 5-50°C (23-113°F)
Solution temperature •••••••••••••••••••••• 0 - 50°C (32 - 122°F)
Transportation and storage temperature••• 10 - 50°C (32 - 122°F)
Installation class•••••••••••••••••••••••••••• II
Pollution level •••••••••••••••••••••••••••••• 2
Audible noise •••••••••••••••••••••••••••••• 71 dbA
Altitude •••••••••••••••••••••••••••••••••••• 1013 mbar
Dimensions •••••••••••••••••••••••••••••••• 159*128.4*139.1mm
Max installation height ••••••••••••••••••••• 1.5 m

9The M3 System® Delivery Module
INSTALLATION
How to install
M3 System
6 steps to install and start-up the delivery module:
1. Main unit mounting
2. Back pressure regulator mounting
3. Piping connections (hoses, injection valve,
pickup valve, back flow pressure regulator)
4. Wirings
5. Pump priming
6. Start-up
The operator must be aware of safety precautions to prevent physical injury.
Disconnect power supply before you perform
any installation or maintenance tasks. Failure to
disconnect power can result in serious physical
injury.
User health
and safety
equipment
Use safety equipment according to
the company regulations. Use the following
safety equipment within the work area:
• Helmet
• Safety goggles (with side shields)
• Protective shoes
• Protective gloves
The work
area
Observe these regulations and warnings in
the work area:
• Always keep the work area clean
• Pay attention to the risks presented by
outside gas and vapors in the work area
• Avoid all electrical dangers. Pay attention to
the risks of electric shock or arc flash hazards
• Avoid water splashes and direct sun
Power supply
disconnection

The M3 System® Delivery Module10
Fig. 2. Installation overview
Pump
location
Requirements
for product
positioning
Pump must be installed on a stable support
at a max 2.0 m height from tank’s bottom.
Injection point must be higher than tank to
avoid accidental chemical injection.
Install the pump:
• In a safe place and fixed flat surface / wall
to avoid vibration problems
• In an easily accessible place
• In vertical position
Use only hoses compatible with product.
Only use fasteners of the proper size and
material. Replace all corroded fasteners.
Make sure that all fasteners are properly
tightened and that there are no missing
fasteners.
Installation
pump
guidelines
Back pressure regulator Delivery hose Air discharge Purge activation button
Power cable
Suction hose
Pick up valve
Nozzle
Andere Handbücher für M3 SYSTEM
1
Inhaltsverzeichnis
Andere Global Steuereinheit Handbücher
Beliebte Steuereinheit Handbücher anderer Marken

Festo
Festo Compact Performance CP-FB6-E Stücklistenhandbuch

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Bedienungsanleitung

JS Automation
JS Automation MPC3034A Bedienungsanleitung

JAUDT
JAUDT SW GII 6406 Series Kurzanleitung

Spektrum
Spektrum Air Module System Bedienungsanleitung

BOC Edwards