GMW IPP 144-40 GS Bedienungsanleitung

Thermal Graphics Printers
IPP 144 - 40 GS
USER`S MANUAL

Safety instructions (EN 61010-1)
In order to preclude any danger to the operator, the following instructions
should be followed:
a) In case any damage or malfunction is detected, take the unit out of operation without delay.
b) Before disassembling the unit, disconnect all inputs / outputs and the supply voltage. When
mounting the unit and the connections, make sure all live components are protected from
being touched directly.
c) Comply with the usual regulations and safety provisions for low and high current systems, in
particular country-specific safety provisions (e.g. VDE 0100).
d) The maximum admissible potential existing between the pin groups as well as to the external
protective conductor must not be exceeded. Refer to the unit´s identification label.
e) When connecting the unit to other devices (e.g. PCs), the connection must be carefully
planned. Internal connections in external units (e.g. GND connected to protective earth) may
cause excessive voltage potential.
f) This device must be grounded! For low voltage 12VDC and 24VDC systems usescreened cable.
Units with a.c. supply voltage must be connected the protective conductor.
g) Make sure that the unit is property mounted before connection and power on !
In order to preclude any damage to the unit, the following items must be
taken into account:
The maximum admissible potential between the pin groups must not be exceeded.
This applies in particular to high voltage tests.
Refer to the instruction manual !
Warning: Hazardous live voltage !
WARNING:
Thereis alwayshazardous voltagepresent incertainpartsduringtheoperationof electricalequipment.
Non-observanceof thesafetyinstructions canresult inseverepersonal injuryor damagetoproperty.Onlyqualified personnelshould
workon thisequipment.The successfuland safeoperationof thisequipment isdependantonpropertransport, storage,set-up,
installationandcareful operationandmaintenance.
QUALIFIED PERSONNEL
Arepersonnel whoarefamiliar withthe set-up,installation,commissioningandoperation ofthe productandhavethequalifications
correspondingto theiractivities, e.g.:
- Aretrained andauthorised toenergise, de-energise,clear, groundand tagcircuitsandequipment/ systemsin accordancewith
establishedsafety standards.
- Aretrained inthepropercareand useof protectiveequipment inaccordance withestablishedsafetypractices.
- Aretrained in first aid.
Safety according to EN 61010-1, VDE 0411
CATIII > 150V[300 V
Pollutiondegree : 2; indoor use;altitude <2000m; relative humidity<80%upto 31°C;
Temperature: 5 °C to 40 °C;

SUMMARY
Safetyinstructions
Introduction 2
First steps 2
Functiondescription 3
Configuration 3
Menuprogram 4
SettingTTY(20mAcurrentloop) 6
Pinassignment 6
Menuprogram/CompleteSelection 7
Graficprint-outdirectlyfromWINDOWS®7
Replacingthepaperroll 8
Possibleerrors 9
Accessories 9
Sparepaper 9
Cable 9
Paperre-rollmechanism 9
Plexiglasscover 13
Appendix A: Design and installation 14
Appendix B: Technical Data 15
Print mechanism 15
Paper 16
Inputbuffer 16
Interface 16
Voltage supply 16
Ambientconditions 16
Standards 17
Connections 17
Miscellaneous 17
Appendix D:Connections 18
RS232 18
TTY 20
Appendix E: Control characters 21
PrintCommands 21
PrintCharacter Commands 22
PrintPositionCommands 25
Bitmapimage Commands 27
LineFeed Commands 31
BarcodeCommands 31
Generalpurpose character,Additional characters
used by the printer 35
Appendix F:Character sets 35
1

Introduction
TheIPP 144-40 GS is an industry-standard panelmountingprinter
designed for outputting data, text and graphics. It is utilised in many fields
ofapplication to give:
faultsignals
machine / process status reports
test reports
production data / statistics
Thethermal printing process requires no maintenance anduses
commercialdocumentgrade thermo paper.The 80 mm widthprovides the
optimumwidth-lengthratio. This paper conforms to the PTB standards.
The printer prints max. 48 characters ( normal font) per line.At least 4600
lines can be printed on a paper roll.
Theshelf-lifeofaprinteddocumentis10yearswhenstoredinanambient
temperatureofunder 60 °C and a relative humidity of under80%.
Transmission is serial by means of an RS 232 (V24) or TTY (20 mA current
loop) interface.A 16 kByte data buffer allows rapid transmission.
To format the text, IPP 144-40 GS supports the most important control
charactersofthesiemensdesktopprinterPT88,e.g.bold,expanded.
Apaperre-rollmechanism(optional)may be installedunderthe printer.A
plexiglasscover allows IP64 protection.
First steps
Suppliedwiththe printer:
intructionmanual,partno.:27866 88139
mounting kit
adaptercablefor connection compatibility with
Siemensdesktopprinter PT88, part no.: 27866 79461
2

- Connect printer to the supply voltage indicated by a cross on
the sticker. ( see pin assignment page 6)
-Establishappropriate data connection (cable description:
appendix D)
- Initiate a data transmission, e.g. hardcopy via message
display, or a PC
Function description
Theprintoutis invented and right justified, which givesthecorrectorder
afterthe paper has been torn off.
TheIPP144-40GSstartstheprintingimmediatelyafterreceptionof<CR>.
The control characters <CR>, <LF> and <FF> are print triggering
characters.Unrecognized control characters are alwaysignored
(Charactersused: appendix E).
If a larger amount of data (more than 100 lines) must be printed at the
same time, a socalled handshake controls the transmission. If the receive
bufferisalmostfull,theprintertransmitsthecharacterXOFFandactivates
theRTS line (neg. voltage). If thebuffercontentsare reduced, the printer
transmits the character XON and switches the RTS line back to passive.
This is also the case when:
- the printer door is open
- the printer is in menu mode
- the paper feed is empty
Pagination is possible via an internal line counter.At the end of a page the
printeradds3blanklines.Thepagelengthisadjustable(appendixE). The
character<FF>enablesa form feed.
Configuration
Theprinterisadaptable to many different applications. the default settings
areappropriate for most of them.
Theset parametersare permanently stored (requires nomaintenance).To
avoidchangingthemenuparametersbyaccident,linkjumperB,
accessible from the front. This jumper is not linked at delivery. JumperA
must remain open all the times.
3

4
Locking the
Menu / Select
key
RESET-key
If the jumper B is connected, the „MENU / SELECT“ key
islocked; menu parameters can neither be printedor
modified.
Inorderto print or modify parameters:
remove jumper B !
The key S102 resets the printer to the standby mode. The
menu parameters will not to be changed.
All functions of the IPP 144 are set via menu program using
the„ENTER“ and „SELECT“ keysandaresaved when the
userquitstheprogram.
From then the IPP 144 automatically uses these
parameters.
Theprint format for the printout of the parametersis always
NORMAL with 48 character per line, so that the parameters
canbe read during printing.
Menu Program

5
Entering the
menu
program
Print current
parameters
Pressthe „Menu/ SELECT“key forapprox. 3s
TheIPP 144 reactsby printing
„ACTUALPARAMETERS ? PRESS ENTER“
Pressthe„ENTER“ key,
theIPP144 prints thecurrentlysetparameters.
Thefinalprintoutsays
„CHANGE PARAMETERS ?“
Press„ENTER“and „SELECT“ simultaneously
forapprox. 4s; the IPP144brings upthe first
functionwhichcan bemodified
(seechanging parameters)
The menu
program
„Change
Parameters“
Themenu program „ChangeParameters“canbe called in
one of two ways:
Without priorprinting of the current parameters:
Press both keys following
„ACTUALPARAMETERS?“.
With priorprintingof the current parameters:
Press both keys following
„CHANGEPARAMETERS?“.
Changing
parameters TheIPP 144 printsone of thechangeable
parameters
Press„ENTER“ toaccept the parameter
andtomovetothenext function
Press„SELECT“ to display the next
parameteroption

6
Setting TTY (20 mA current loop)
If the transmission to the printer must be executed by means of the TTY
interface, the selection switch must be positioned to the left. Default
position is right: RS 232. Slide snap lock to the right hand side, swivel front
door out. Now you can see the switch S 101 on the printed circuit board.
-For RS 232 C, RS 422 and RS 485 set switch S 101
to the right hand side.
-For Current loop, set switch S 101 to the left hand side.
Pin assignment
WARNING: This device must be grounded -ACHTUNG: Dieses Gerät muss geerdet werden !
IPP 144 - 40 G
Opt.: . . . . . . .
.
Alarm
LN
1
+-
Serien Nr.:
Serial No.:
No.de serie
Lithium battery inside ( VERSION E )
CE
IPP-AW
10 V...19 V DC; 20 VA
19 V...36 V DC; 18 VA
InterfaceII
InterfaceI 1
6
RS232 C
RS485
Profi Bus
USB
1
SigGND
RXD (+)
5
9
RTS
RTS
DTR
DTR
TXD
CLA
+5Vis
GND
RXD (-
)
6
5
9
RTS
DTR
SigGND
TXD
RXD
GND
85 V...265 V AC; 45...60Hz ; 15W
EN 61010 -1:2001 CAT III
Connect the unit as shown in the connection diagramms.
Observeall national safety regulations, especially for supplypower
connections.
Quitting the
menu
program
If therearenokeyspressed over a period of approximately
2 minutes, the program is terminated automatically and any
modifications made are not saved.
Theprogramisterminatedby simultaneously
pressing„ENTER“ and „SELECT“.
Followingtheprintout
„END“
allmodified functions aresaved.

Menu program / Complete Selection
SET INTERVAL NO ?
YES?
SETINTERVAL 00h 00min00 sec
00h00min_0 sec
00h0_min50 sec
00h_4min50 sec
0_h34min50 sec
_2h34min50 sec
>>> 12h 34min50 sec
SETBAUDRATE NO?
YES?
BAUDRATE 19200
19200
38400
110
150
300
600
1200
2400
4800
9600
>>> 9600
SETDATAFORMAT NO?
YES ?
SETDATAFORMAT 8
8
7
>>> 7
SET PARITY NO ?
YES?
SETPARITY NOPARITY
NOPARITY
EVEN
ODD
MARK
SPACE
NOPARITY
>>> NOPARITY
PRINTERADDRESS NO ?
YES?
PRINTERADDRESS 00
_0
10
20
30
00
0_
01
.
.
09
00
>>> 00
SET PRINT FORMAT NO ?
YES?
PRINT FORMAT INVERSE
INVERSE
NORMAL
>>> NORMAL
SETCHARACTER/LINE NO ?
YES?
CHARACTER/LINE 48CHARACTERS
48CHARACTERS
40CHARACTERS
24CHARACTERS
20CHARACTERS
16CHARACTERS
8 CHARACTERS
>>> 8 CHARACTERS
CHARACTERSET NO?
YES?
SETCHARACTER ASCII
ASCII
GERMAN
FRENCH
DANISH
NORWEGIAN
SPANISH
UK
CYRILLIC
ASCII
>>> ASCII
SETINTERFACE NO ?
YES?
SETINTERFACE SERIAL
SERIAL
EMUL.EPS.LQ580ESC/P2
EMUL.TALLYT2024
>>> EMUL.TALLYT2024
*** END ***
7
It is possible to print graphics, such as bmp-, jpg- or tif-, directly from W INDOWS®
programs.Setthe printer INTERFACE ofEMUL.EPS.LQ580ESC/P2or
EMUL.TALLYT2024. Usea24-pintype WINDOWS®printer.
Thefollowingconfigurations havebeen verified:
INTERFACE:EMUL.EPS.LQ580 ESC/P2
WINDOWS®printerdriver:EpsonCompatible 24 PIN and Epson LQ560
Details:
If the width of the graphic exceeds the paper print width, then the excess is
discarded. It is recommended to use the auto-sizing print option in WiNDOWS®
programs,where possible.
Print graphics directly from WINDOWS®

8
Replacing the Paper Roll
Proceedas described below:
1. For devices with a.c. power supply be very careful.
2. Push the snap lock to the right hand side and open the
frontpanel.
3. Tilt the wire frame upwards;
removethe old paperroll.
4. Insert new paper roll; make sure it rotates clockwise
duringprinting(see left side of the figure).
5. Trim the leading edge of the paper roll to get a clean
straightedge(seerightsideofthefigure). Insert
paper into bottom of print mechanism (as shown in the
diagram below) until roller automatically takes it up.
6. Press the „LINE FEED / ENTER“ key until the paper
appearsatcuttingedge.
7. Ifyouhave fed too much paper, carefully rewind the roll.
pushthewireframeback over the roll.
8. Close the front panel (snap lock must lock). TheAlarm
LED extinguishes and the printer is ready.
Warning: Dangerous voltage
is accessible if replacing the paper roll after
opening of the front panel !