H-Tec Education E208 Bedienungsanleitung

Operating Instructions
E208 - 1-Cell Rebuildable PEM Electrolyzer Kit

2www.myhtec.com
Table of Contents
02
03
04
05
07
07
07
08
09
11
14
15
15
15
Table of Contents
Introduction
Intended Use
General Safety Precautions
Contents
Required Additional Components/Equipments
Optional Equipments
Operation of a PEM Electrolyzer
Different Operational Modes for Electrolyzers
Assembly/Disassembly
Operation of the Electrolyzer Cell
Technical Data
Troubleshooting
Disposal

www.myhtec.com 3
Introduction
Diminishing resources, more severe environmental impacts originated from the current power
plants, and the ever-increasing demand for energy forces us to re-evaluate the structure of our
energy storage supply systems. Automobile and oil companies increasingly invest in hydrogen
technologies (such as fuel cells, electrolyzers, etc.) because such clean technologies offer
smart and innovative solutions to some of these future energy related concerns. The Proton
Exchange Membrane (PEM) Electrolyzer is one of the most fascinating, clean electrochemical
technologies. It provides a unique and highly efficient energy storage via an electrolysis
reaction, with minimal impact on our natural resources.
It is important to learn about this technology, especially for young people, who will most likely
spend a large part of their lives with it.
The 1-Cell Rebuildable PEM Electrolyzer Kit offers the possibility to become familiar with
hydrogen technologies (particularly generation of hydrogen) in a step-by-step procedure, by
way of simple experiments.
The 1-Cell Rebuildable PEM Electrolyzer Kit represents the state-of-the-art technology for
the components that are used in the hardware. It can be used for practical demonstration
of the operation of electrolyzers (which are also known as hydrogen generators in the
industry) by means of simple experiments. This electrochemical cell can be completely
dismantled (meaning disassembled and reassembled) and can therefore also be used for vivid
demonstration of an electrolyzer design to students or researchers.
The 1-Cell Rebuildable PEM Electrolyzer Kit is consistently environmentally conscious in all
operating modes, requiring only de-ionized or distilled water and a small power supply for the
generation of hydrogen and oxygen gases from the electrolysis reaction of water.
All steps required for setup, operation, and assembly/disassembly of the 1-Cell Rebuildable
PEM Electrolyzer Kit are described in this manual.
Please read through the Operating Instructions carefully before operation.
H-TEC Education wishes you many enjoyable hours learning about this tecH-TEC Education wishes you many enjoyable hours learning about this technology with thehnology with the
1-Cell Rebuildable PEM Electrolyzer Kit.1-Cell Rebuildable PEM Electrolyzer Kit.

4www.myhtec.com
Intended Use
The 1-Cell Rebuildable PEM Electrolyzer Kit allows the measurement and demonstration of the
principles of Proton Exchange Membrane (PEM) Electrolyzers and PEM Fuel Cells. The system has
been developed for teaching and demonstration purposes only.
Any other use is prohibited!
De-ionized or distilled water, a power supply, and a multimeter are required for the operation of
the 1-Cell Rebuildable PEM Electrolyzer Kit.
Should the equipment be used improperly, the generated hydrogen and oxygen gases present
a hazard. Additionally, the externally attached power supply may also become a point of hazard
in the case of incorrect usage of this educational PEM Electrolyzer Kit. To prevent accidents,
observe the General Safety Precautions at all times when working with the 1-Cell Rebuildable
PEM Electrolyzer Kit.

www.myhtec.com 5
• The system is intended for teaching
and demonstration purposes in schools,
universities, institutions, and companies
only.
• It may only be set up and operated by a
competent person.
• Read the Operating Instructions before
setting up the 1-Cell Rebuildable PEM
Electrolyzer Kit. Follow them during
use and keep them readily available for
reference.
• Wear protective goggles and other PPEs.
• Remove inflammable gases, vapors, and
fluids from the vicinity of electrolyzers
and fuel cells. The catalysts contained
in the system can trigger spontaneous
combustion.
• Hydrogen and oxygen are
the two main gases that are
generated by the electrolyzer
system. To prevent the
gases collecting and forming
explosive mixtures only use the system
in well-ventilated rooms. Do not obstruct
the inlet and outlet ports of the system
and prevent pressure building up inside
the cell.
• Hoses, plugs, and tanks are used for
pressure compensation. They must
not be fixed or secured with clamps,
adhesive, etc.
General Safety Precautions
• The system is not a toy. Operate the
1-Cell Rebuildable PEM Electrolyzer Kit
according to the instructions provided
in this booklet and keep the cell and the
gases produced by the electrochemical
cell out of the reach of small children.
• Unless specified otherwise, do not
short-circuit or reverse the polarity of the
terminals.
• Do not operate the system dry. Always
ensure that it contains sufficient liquid
de-ionized water or liquid distilled water
at the anode side of the electrolyzer cell.
• The system may only be operated in
a display case, which is sufficiently
ventilated at all times. The operator
is obliged to prove this by means of
appropriate measurements.
• Do not smoke near this device.
• Only use the gas storage tanks belonging
to or supplied with the system to store
the generated gases during the operation
of the electrolysis cell. Never connect
other alternatives.
• Only operate the system at room
temperature and ambient pressure.
• De-ionized water or distilled water needs
to be transferred into the anode side of
the electrolyzer cell in the liquid form or
while its temperature is in the range of
5 deg. Celsius to 60 deg. Celsius. In the
case of using warmed liquid water, the
user needs to use the proper PPE.

6www.myhtec.com
• Do not operate the system dry. Always
ensure that it contains sufficient amount
of liquid de-ionized water or liquid
distilled water at the anode side of the
electrolyzer cell.
• Remove anything in the vicinity
of the electrolyzer cell that may
ignite the generated hydrogen
gas (naked flame, materials
that can become charged with static
electricity, substances with catalytic
properties such as platinum powder,
etc.).
• Remove all the substances from
the vicinity of the system that could
spontaneously ignite with increased
oxygen concentration.
• Tell the students about any potential
dangers and carefully supervise
experimentation.
General Safety Precautions
• Hoses, plugs, and tanks, etc. are used for
pressure compensation. They must not
be fixed or secured or obstructed with
clamps, adhesive, stoppers, etc.
• The power source of this electrolyzer
can be based on solar sources too. Do
not position any solar modules and
lights in use closer than the minimum
permitted distance (50 cm between
H-TEC Education solar modules and the
H-TEC Education Spotlight, or see other
manufacturers’ stipulations).
• The surface of solar modules can get
very hot during extended operation.
H-TEC Education does not accept responsibility for injuries or damage sustained in the event ofH-TEC Education does not accept responsibility for injuries or damage sustained in the event of
these Safety Precautions not being followed.these Safety Precautions not being followed.

www.myhtec.com 7
Contents
Housing plates
Recessed hex-head
screws & washer
Fittings
Catalyst
coated
membrane
Nuts
Fittings
Perforated plates
with electrodes
This PEM electrolyzer cell can be fully disassembled and re-assembled in order to see the design
aspect and the internal components for educational purposes.
Required Additional
Components/Equipments:
•• Commercial distilled waterCommercial distilled water (or(or
deionized water)deionized water) with a conduc-
tivity of < 2 µS/cm
• Connecting hoses
• Power supply (0 to 2.5 V and 0 to
5 Amps)
• Multimeter
Optional Equipments:
• Fuel Cell H2/O2/Air
Item No: F103
• Storage 80
Item No: A153
This PEM electrolyzer cell can also be used in conjunction with other educational fuel cell kits in
order to consume the generated hydrogen and oxygen gases to produce electrical energy.

8www.myhtec.com
Operation of a PEM Electrolyzer Cell
In an electrolyzer cell, the electrical energy that is being provided from an external source is used
to split the de-ionized water (or distilled water) in order to generate hydrogen and oxygen gases.
In other words, electrical energy is being converted into chemical energy with the aid of the
electrolyzer cell. This electrochemical reaction is also known as electrolysis.
In the electrolyzer cell, the electrochemical reactions are carried out on the catalyst located
at the anode and cathode. In PEM electrolyzers, anode and cathode catalysts are usually
applied directly to the surface of the membrane. Sometimes, only the anode electrode catalyst
is applied to the membrane surface and cathode catalyst is applied to the surface of the gas
diffusion layer. An example for anode catalyst is iridium ruthenium oxide or iridium black. An
example of cathode catalyst is platinum black or platinum on carbon. As the name suggest, PEM
electrolyzers utilize a proton (H+) exchange membrane (such as Nafion). In addition to these
components, a metallic diffusion medium is used at the anode side to evenly disperse the liquid
water, vent out the generated gases, and provide electrical contact. At the cathode, on the other
hand, a carbon based gas diffusion layer is used to vent out the hydrogen gas and also provide
electrical contact.
The combination membrane-catalysts-diffusion media forms the heart of the PEM electrolyzer
cell. The following reactions take place within the PEM electrolyzer system:
Cathode:
4e-+ 4H+2H2
Anode:
2H2O O2 + 4H++ 4e-
Complete reaction:
2H2O 2H2+ O2
In this 1-Cell Rebuildable PEM Electrolyzer Kit, de-ionized water (in the liquid phase) is supplied
to the anode chamber. Under the catalytic action of the anode electrode, water molecules get
oxidized to oxygen gas, protons (H+), and electrons (e-) on the surface of the catalyst particles.
The H+ions migrate through the proton-conductive membrane to the cathode side due to the
existing cell voltage gradient. The electrons, on the other hand, travel to the cathode through
the external electrical circuit and recombine with protons in order to generate the hydrogen gas.
At the anode, an oxidation reaction would occur. At the cathode, on the other hand, a reduction
reaction would occur. In any electrochemical cell (whether using an electrolyzer or fuel cell),
an oxidation reaction has to accompany a reduction reaction in order to maintain the ion and
electron neutrality.

www.myhtec.com 9
Different Operational Modes for Electrolyzers
“Anode-fed” versus “Cathode-fed” electrolysis modes“Anode-fed” versus “Cathode-fed” electrolysis modes
PEM electrolyzer hardware are usually configured to work in one of the following mode: anode-
fed or cathode-fed. The mode of operation is usually dictated by the application itself. For
example, if the application requires pure hydrogen with minimal moisture content, the anode-
fed design is more efficient. If the application requires pure oxygen with minimal moisture, the
cathode-feed design is more applicable.
In the anode-fed configuration, the liquid de-ionized water is transferred to the anode chamber.
On the other hand, the cathode-fed mode requires the liquid de-ionized water to be transferred to
the cathode chamber.
Anode-fed configuration would usually have the following sub-components in the electrolyzer
cell as its diffusion media: carbon-based gas diffusion layer for the cathode and metallic mesh
or metallic screen for the anode. Cathode-fed electrolyzers, on the other hand, would have the
following as its diffusion media: metallic mesh or metallic screen for anode and metallic mesh or
metallic screen for the cathode.
Since electrolysis reaction requires the water to be present on the anode electrode catalyst layer,
anode-fed designs are more efficient compared to cathode-fed designs. While anode-fed design
allows the water to be transferred directly to the anode catalysts, the cathode-fed design would
have to wait for water molecules to be transferred from cathode side to the anode through the
membrane (natural diffusion, which is a slow process) before the electrolysis reaction can start.
1-Cell Rebuildable PEM Electrolyzer Kit is based on anode-fed electrolysis mode and hence, it
requires the de-ionized water to be transferred to the anode chamber. De-ionized water can
be transferred to the anode inlet port via two simple mechanisms: gravity-fed by using another
H-TEC Education product such as Storage 80 (Item No: A153) or forcefully-fed (also known as
active-fed approach) with the help of a small liquid pump. If the gravity-fed approach is being
used, the user should store the water in a manner such that the water level is higher than the top
port on the electrolyzer. If the user is intending to use a small liquid pump, there is no need to
place the storage tank at a higher level because mechanical movement of the pump will actively
push the water. The maximum amount of water to be pumped is not to exceed 70-80 milliliters
per minute. Too much water flow can create leaks around the seals.
In order to prevent damage to the cell, the anode should remain full of water at all times.

10 www.myhtec.com
Different Operational Modes for Electrolyzers
“Anode-fed” electrolysis mode“Anode-fed” electrolysis mode
Before attaching the power supply to the electrolysis cell, it is advised to follow the following
steps:
1. Obtain a pure de-ionized water (or distilled water) in sufficient quantities. 500 mL to 1000 mL
of volume of water can be used for multiple hours.
2. Transfer a sufficient amount of water in to the water storage tank that you will be using for the
electrolysis experiment.
3. Use a soft tubing (such as silicone tubing) of the appropriate diameter to make a connection
between the water storage tank and the inlet of the anode side of the electrolyzer cell.
4. Attach another piece of soft tubing to the outlet of the anode side of the electrolyzer and place
the end of this tube into the water storage tank. (During the electrolysis reaction, only a small
quantity of liquid water is used and unconsumed water should be recycled back into the storage
tank for further use and reduce waste).
5. Attach soft tubing to inlet and outlet ports of the cathode side (one piece of tubing for each
port) where hydrogen generation will occur and place the ends of these tubes into another empty
storage vessel. During the electrolysis reaction, some of the water will be carried over to the
cathode side and if desired, this water can also be recycled. CAUTION: Do not place the cathodeCAUTION: Do not place the cathode
side tubings’ end to the storage that has anode side tubings. Hydrogen and oxygen mixtures canside tubings’ end to the storage that has anode side tubings. Hydrogen and oxygen mixtures can
easily create a gas mixture with explosive nature and cause serious injuries.easily create a gas mixture with explosive nature and cause serious injuries.
6. Place the anode side and cathode side storages away from each other in order to prevent
formation of explosive gas mixtures. Ensure the area is well ventilated.
7. Do not restrict the liquid or gas flows through the tubings. Do not restrict the inlet and outlet
ports located at the anode and cathode sides. Pressurization inside the electrolysis cell can
cause leakages and possibly damaging the membrane and hence, the hardware.
8. Temperature of the de-ionized water can be in the range of 5° to 60° Celsius. Use caution
with warmed or hot water and use proper personal protective equipments (PPEs, safety glasses
or safety googles, gloves, heat resistant gloves, lab coat, etc.) for the safe operation of the
hardware and safety of the user.
Inhaltsverzeichnis
Beliebte Robotik Handbücher anderer Marken

STEMCenter USA
STEMCenter USA Pi-Bot v2.00 Bedienungsanleitung

SunFounder
SunFounder PiDog Bedienungsanleitung

Universal Robots
Universal Robots UR5 Bedienungsanleitung

Universal Robots
Universal Robots E Series Bedienungsanleitung

YASKAWA
YASKAWA MOTOMAN-MPL80 II Bedienungsanleitung

EFORT
EFORT ECR5 Gebrauchsanweisung











