Halma BEA LZR-FLATSCAN Betriebsanleitung

REMOTE CONTROL
©BEA | Original Instructions
75.0043.01 REMOTE CONTROL 20211102 Page 1 of 12
How to use the remote control
ENGLISH
KEYS
Visit website for available
languages of this document.
See pages 3 – 12 for button assignments per product.
GENERAL KEYS
Unlock
Lock
Check value
Incremental increase
Incremental decrease
Setup / Teach-in
Factory values
Presettings
COLOR KEYS
LZR-FLATSCAN LZR-WIDESCAN
/ Virtual Pull Cord
Safety Safety
Motion Reopening
/ Presence
FUNCTION KEYS

1x
x
*
x
©BEA | Original Instructions
75.0043.01 REMOTE CONTROL 20211102 Page 2 of 12
Tech Support & Customer Service: 1-800-523-2462 | General Tech Questions: [email protected] | Tech Docs: www.BEAsensors.com
1 Min.
SAVING AN ACCESS CODE
DELETING AN ACCESS CODE
enter the existing code
The access code (1 – 4 digits) is recommended to set sensors that are installed close to each other.
LED flashes quickly
LED flashes LED is off
LED flashes slowly
LED flashes once
ADJUSTING ONE OR MORE PARAMETERS
CHECKING A VALUE
RESTORING TO FACTORY VALUES
X = number of
flashes = value of
the parameter
* When no green LED is available, the signal is red.
After unlocking, the
red LED flashes and the
sensor can be adjusted
by remote control.
choose parameter
choose parameter
choose value
press ?
press 9
press 0
press UNLOCK
press UNLOCK
press UNLOCK
press UNLOCK
press UNLOCK
press UNLOCK
press UNLOCK
press LOCK
press LOCK press LOCK
press MAGIC WAND
press LOCK enter 4 digits
enter 4 digits
press LOCK twice
press LOCK twice
press LOCK twice
If the red LED flashes quickly after
unlocking, you need to enter an access
code from 1 to 4 digits.
To end an adjustment session,
always lock the sensor.
enter the existing code
If you forget the access code, proceed as follows:
CHANGING AN ACCESS CODE
During 1 minute, you can access the sensor without access code
Cut and restore
power to the sensor
GENERAL REMOTE USE

©BEA | Original Instructions
75.0043.01 REMOTE CONTROL 20211102 Page 3 of 12
APPENDIX: LZR-I30 / LZR-S600 FUNCTIONS
BUTTON FUNCTION
MOUNTING SIDE LEFT
(background)
RIGHT
(background)
LEFT
(no background)
RIGHT
(no background)
CENTER
(no background)
OPTIONAL FIELD WIDTH I30: no field = 000 / minimum = 020 / maximum = 360 / default = 200
S600: no field = 000 / minimum = 020 / maximum = 984 / default = 400
OPTIONAL FIELD HEIGHT I30: no field = 000 / minimum = 020 / maximum = 360 / default = 200
S600: no field = 000 / minimum = 020 / maximum = 984 / default = 400
SAFETY FIELD WIDTH I30: no field = 000 / minimum = 020 / maximum = 360 / default = 200
S600: no field = 000 / minimum = 020 / maximum = 984 / default = 400
SAFETY FIELD HEIGHT I30: no field = 000 / minimum = 020 / maximum = 360 / default = 200
S600: minimum = 004 / maximum = 984 / default = 400
ACTIVE DETECTION
CURTAINS
deactivate
curtain on
both fields
activate
curtain only on
optional field
activate
curtain only
on safety field
activate
curtains on
both fields
UNCOVERED ZONE 2 in
(S600 default)
4 in
(I30 default) 6 in 8 in 10 in
IMMUNITY FILTER environment:
indoor
environment:
outdoor low
environment:
outdoor med.
environment:
outdoor high
objects:
indoor
objects:
outdoor low
objects:
outdoor med.
objects:
outdoor high
MIN. OBJECT SIZE off 2 in 4 in 6 in 8 in
OUTPUT ACTIVATION
DELAY off 100 ms 200 ms 300 ms 400 ms 500 ms 600 ms 700 ms 800 ms 900 ms
DETECTION FIELD
REDIRECTION
R1: optional
R2: safety
R1: optional
or safety
R2: safety
OUTPUT
CONFIGURATION
R1: A - NO
R2: P - NC
R1: P - NC
R2: A - NO
R1: P - NC
R2: P - NC
R1: A - NO
R2: A - NO
Click here for LZR-I30 User’s Guide.
Click here for LZR-S600 User’s Guide.

©BEA | Original Instructions
75.0043.01 REMOTE CONTROL 20211102 Page 4 of 12
APPENDIX: FALCON, FALCON EX, PHOENIX EX FUNCTIONS
BUTTON FUNCTION
FIELD SIZE XXS XS S > > > > L XL XXL
HOLD-OPEN TIME 0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s
OUTPUT
CONFIGURATION active passive
DETECTION MODE BI UNI UNI AWAY
DETECTION FILTER 123456
Click here for FALCON Family User’s Guide.
Click here for FALCON EX Family User’s Guide.
Click here for PHOENIX EX Family User’s Guide.

©BEA | Original Instructions
75.0043.01 REMOTE CONTROL 20211102 Page 5 of 12
APPENDIX: IS40 / IS40XL FUNCTIONS
BUTTON FUNCTION
FIELD SIZE (SENSITIVITY) XXS XS S > > > > L XL XXL
HOLD-OPEN TIME 0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s
DETECTION MODE BI UNI UNI AWAY
DETECTION FILTER All targets in
motion
All targets
in motion +
interference
immunity
Low
‘Pedestrian/
Parallel traffic’
Rejection +
Interference
Immunity
Medium
‘Pedestrian/
Parallel traffic’
Rejection +
Interference
Immunity
High
‘Pedestrian/
Parallel traffic’
Rejection +
Interference
Immunity
Extra High
‘Pedestrian/
Parallel traffic’
Rejection +
Interference
Immunity
OUTPUT
CONFIGURATION
Presence
+
Activation:
standard
mode
Presence
+
Activation:
pulse on entry
Presence
+
Activation:
pulse on exit
Presence
+
Activation:
pulse on entry
first / last line
Presence
+
Activation:
pulse on exit
first / last line
Presence
+
Activation:
remains active
(when motion
is detected)
until presence
zone in
cleared
Presence
+
Activation:
remains active
(when motion
and AIR are
detected) until
presence zone
in cleared
FREQUENCY A B
MAX. PRESENCE
DETECTION TIME 30 s 1 min 2 min 5 min 10 min 20 min 1 hr 1.5 hr 2 hr no learn
AIR CURTAIN IMMUNITY low normal high
TARGET SIZE
AIR PATTERN SIZE
Click here for IS40 / IS40XL User’s Guide.

©BEA | Original Instructions
75.0043.01 REMOTE CONTROL 20211102 Page 6 of 12
APPENDIX: IS40P FUNCTIONS
BUTTON FUNCTION
RELAY CONFIGURATION Mot: active
Pres: passive
Mot: passive
Pres: active
Mot: passive
Pres: passive
Mot: active
Pres: active
OUTPUT REDIRECTION ACT: presence
PRES: presence
ACT: AIR entry
pulse
PRES: presence
ACT: AIR exit
pulse
PRES: presence
ACT: first/last
line AIR entry
pulse
PRES: presence
ACT: first/last
line AIR exit
pulse
PRES: presence
ACT: presence
PRES: presence
ACT: presence
PRES: presence
FREQUENCY A B
MAX. PRESENCE
DETECTION TIME 3 s 1 min 2 min 5 min 10 min 20 min 1 hr 1.5 hr 2 hr no learn
AIR CURTAIN IMMUNITY low normal high
TARGET SIZE
AIR PATTERN SIZE
Click here for IS40P User’s Guide.

©BEA | Original Instructions
75.0043.01 REMOTE CONTROL 20211102 Page 7 of 12
APPENDIX: EAGLE FAMILY FUNCTIONS
BUTTON FUNCTION
ZONE SIZE XXS XS S > > > > L * XL * XXL
IMMUNITY FILTER low normal high > > > L XL highest
DETECTION MODE BI UNI UNI MTF UNI AWAY MTF & AWAY
OUTPUT
CONFIGURATION A P
HOLD-OPEN TIME 0.5 s 1 s 2 s 3 s 4 s 5 s 6 s 7 s 8 s 9 s
MOUNTING HEIGHT < 10 ft ** > 10 ft **
DOOR CONTROL auto open closed
Click here for EAGLE Family User’s Guide.
* EAGLE default = 8, EAGLEHM default = 7
** EAGLE default = 1, EAGLEHM default = 2

©BEA | Original Instructions
75.0043.01 REMOTE CONTROL 20211102 Page 8 of 12
APPENDIX: BODYGUARD-T FUNCTIONS
BUTTON FUNCTION
INTERFACE new style old style
(LO21)
DOOR CONTROL normal
door
permanently
open
door
permanently
closed
MODES OF OPERATION normal MP mode Record mode
INFRARED FREQUENCY Mode: normal
Freq: low
Mode: normal
Freq: high
Mode: quiet
Freq: low
Mode: quiet
Freq: high
SENSITIVITY min > > > > > > * > * > >
HOLD TIME 0.5 s > > > > > > > > 9 s
OUTPUT
CONFIGURATION N.O. N.C.
AUTO-LEARN TIME 30 s 1 m 2 m 3 m 5 m 7 m 10 m 15 m 10 s infinite
PATTERN WIDTH wide
(closed door)
middle
(open door)
asymm. left
narrow
asymm. right
narrow narrow left narrow right asymm. left
wide
asymm. right
wide center narrow
PATTERN DEPTH deep
(threshold on)
medium
(threshold on,
open)
limited
(threshold on)
deep
(threshold off)
medium
(threshold off,
closed)
limited
(threshold off)
IMMUNITY low
(normal)
medium
(rain)
high
(snow)
Click here for IS40 / IS40XL User’s Guide.
* default 6 = door closed, default 7 = door open

©BEA | Original Instructions
75.0043.01 REMOTE CONTROL 20211102 Page 9 of 12
APPENDIX: LZR-FLATSCAN SW FUNCTIONS
BUTTON FUNCTION
PINCH ZONE WIDTH no field = 000 / minimum = 001 / maximum = 040 / default = 015
PINCH ZONE HEIGHT no field = 000 / minimum = 001 / maximum = 157 / default = 157
DOOR LEAF WIDTH no field = 000 / minimum = 001 / maximum = 157 / default = 157
DOOR LEAF HEIGHT no field = 000 / minimum = 001 / maximum = 157 / default = 157
OUTPUT
CONFIGURATION
R1: NO
R2: NC
R1: NC
R2: NO
R1: NC
R2: NC
R1: NO
R2: NO
IMMUNITY FILTER low > > > > > > > high
UNCOVERED ZONE 3⁄4in 1 1⁄2in 2 1⁄4in 3 in 4 in 4 3⁄4in 5 1⁄2in 6 1⁄4in 7 in
ANTIMASKING &
BACKGROUND OFF / OFF OFF / ON ON / OFF ON / ON
Click here for LZR-FLATSCAN SW User’s Guide.

©BEA | Original Instructions
75.0043.01 REMOTE CONTROL 20211102 Page 10 of 12
APPENDIX: LZR-FLATSCAN 3D SW FUNCTIONS
BUTTON FUNCTION
PINCH ZONE WIDTH no field = 000 / minimum = 001 / maximum = 040 / default = 015
DOOR LEAF WIDTH no field = 000 / minimum = 001 / maximum = 157 / default = 157
DOOR LEAF HEIGHT no field = 000 / minimum = 001 / maximum = 157 / default = 157
OUTPUT
CONFIGURATION N.O. N.C.
UNCOVERED ZONE 3⁄4in 1 1⁄2in 2 3⁄8in 3 1⁄4in 4 in 4 3⁄4in 5 1⁄2in
ANTIMASKING /
BACKGROUND OFF / OFF OFF / ON ON / OFF ON / ON
DETECTION FIELD DEPTH
1 curtain 2 curtains 3 curtains 4 curtains
Click here for LZR-FLATSCAN 3D SW User’s Guide.
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Beliebte Fernbedienung Handbücher anderer Marken

Panasonic
Panasonic EUR7622KB0 Bedienungsanleitung

Bang & Olufsen
Bang & Olufsen Beo4 Bedienungsanleitung

Sunwave Tech.
Sunwave Tech. RemoteComm SRC-7000 Bedienungsanleitung

Multiplex
Multiplex PROFI TX 9 Bedienungsanleitung

One Remote
One Remote RMB4 Bedienungsanleitung

FUTABA
FUTABA 9ZAP - PART2 Bedienungsanleitung