Hama 00186425 Bedienungsanleitung

D
GB
Operating Instructions
Bedienungsanleitung
Air Quality Detector
Luft Qualitäts Messgerät
00
186425
Air quality detector
TVOC 0.0
0002
0684
0.0300 2
mg/m3
mg/m3
ppm
ppm
AQI
CO
CO2
HCHO
ON/OFF RESET ANEW


2
Air quality detector
TVOC 0.0
0002
0684
0.03002
mg/m3
mg/m3
ppm
ppm
AQI
CO
CO2
HCHO
ON/OFF RESET ANEW
1
2
3
10
456
7
11
8
9

2
GOperating instruction
1. Controls and displays
1. Battery label: Battery charge level
2. TVOC: Total Volatile Organic Compounds in mg/m³. Substances containing
hydrocarbons that evaporate at low temperatures. Values above 10 mg/m3are
considered unacceptable for hygiene. Noticeable effects arelack of concentration,
exhaustion, dry skin through to eczema or headaches.
3. AQI: Air Quality Index
4. ON/OFF: On/Off button
5. RESET: Data cleansing and new measurement
6. ANEW: Instrument calibration
7. HCHO: Formaldehyde concentration in mg/m³ (HCHO =CH₂O)
HCHO: Formaldehyde is an organic chemical compound with the molecular formula
CH₂O. Under standardconditions formaldehyde is agas with apungent odour.
According to the European Union, formaldehyde can increase the risk of cancer.The
Federal Institute for Risk Assessment (BfR) has set the tolerable concentration for
CH₂Oat0.1 ppm, corresponding to 0.124 mg/m³.
8. CO2: Carbon dioxide concentration in ppm (parts per million =
1millionth =1ppm =10
-6 -corresponds to 0.001 ‰) The Federal Environment
Agency recommends letting fresh air into the room from outside if avalue of 1,000
ppm CO₂is exceeded.
9. CO: Carbon monoxide concentration in ppm. In unventilated rooms with gas
burners, replaces or cigarette smoke, higher values arequickly reached. If the
CO concentration rises to values between 136 and 280 ppm, fatigue, dizziness
and nausea occur after only two to three hours. Avalue of 368 ppm or moreis
considered to be unhealthy exposure, higher values areconsidered to be directly
life-threatening.
10. Vents: Ventilation opening
11. Charging Point: Charging socket
Thank you for choosing aHama product.
Take your time and read the following instructions and information completely.Please
keep these instructions in asafe place for futurereference. If you sell the device, please
pass these operating instructions on to the new owner.
2. Explanation of warning symbols and notes
Warning
This symbol is used to indicate safety instructions or to draw your attention to
specichazards and risks.
Note
This symbol is used to indicate additional information or important notes.

3
3. Package contents
•1air quality detector
•1micro-USB connection cable*
•These operating instructions
*for charging or continuous operation, an external USB power supply unit 5V min. 1A is required.
4. Safety instructions
•The product is intended for private, non-commercial use only.
•Use the product only for the intended purpose.
•Protect the product from dirt, moistureand overheating and use it in dry rooms only.
•Donot use the product in the immediate vicinity of heaters, other heat sources or in
direct sunlight.
•Aswith all electrical products, this device should be kept out of the reach of children.
•Donot operate the product outside the power limits specied in the technical data.
•Donot use the product in areas in which electronic products arenot permitted.
•Donot use the product in adamp environment and avoid splashing water.
•Donot place the product near interference elds, metal frames, computers, TVs,
etc. Electronic devices and window frames can negatively affect the product’s
functionality.
•Donot drop the product and do not expose it to any major shocks.
•Donot modify the product in any way.Doing so voids the warranty.
•Keep the packaging material out of the reach of children due to the risk of
suffocation.
•Dispose of packaging material immediately in accordance with the locally applicable
regulations.
•Route all cables so that thereisnorisk of tripping.
•Do not bend or crush the cable.
•Only use the article under moderate climatic conditions.
•The battery is integrated and cannot be removed.
•Do not open the device or continue to operate it if it becomes damaged.
•Do not attempt to service or repair the product yourself.Leave any and all service
work to qualied experts.
•Do not incinerate the battery or the product.
•Do not tamper with or damage/heat/disassemble the batteries/rechargeable
batteries.
•The product and the measurements it displays areintended for use in the home, offer
no absolute accuracy and do not satisfy the requirements needed and/or prescribed
in professional applications.
•This product and its measured values may not be used for professional applications
or to inform the public.

4
5. Getting started
The product can be used both in battery and mains operation. Forbattery operation,
fully charge the product once before rst use.
5.1 Battery operation
Warning –rechargeable battery
•Only use suitable charging devices or USB connections to charge the product.
•Do not use defective chargers or USB ports and do not attempt to repair them.
•Do not overcharge the product or allow the battery to completely discharge.
•Avoid storing, charging and using in extreme temperatures and at extremely low
atmospheric pressures (such as at high altitudes).
•Charge regularly (at least quarterly) during periods of prolonged storage.
•Connect the supplied micro-USB charging cable to the micro-USB port (11) on the
product.
•Connect the free plug on the micro-USB charging cable to asuitable USB charger.To
do this, consult the operating instructions for the USB charger you areusing.
•The battery indicator (1) indicates the charge level by means of the red-yellow-green
colour code.
•When the battery is fully charged (green) the charging process can be terminated.
Disconnect the product from the mains.
•In the case of battery operation, the display goes out after approx. 30 minutes. Press
ON/OFF (4) brieytomake the display appear again.
Note –charging process
•Acomplete charging cycle takes about 4hours.
•The product's battery can be charged both when it is switched on and off.
•When fully charged (green), the maximum operating time is approx. 180 to 240
minutes.
5.2 Mains operation
•Connect the supplied micro-USB charging cable to the micro-USB port (11) on the
product.
•Connect the free plug on the micro-USB charging cable to asuitable USB charger.To
do this, consult the operating instructions for the USB charger you areusing.
•In continuous operation with aUSB cable, the display is permanently visible.
5.3 Switching on/off
•Remove the protective lm from the display.
•Press and hold ON/OFF (4) for approximately 3seconds to switch on the product.
•After switching on, the device needs approx. 120 seconds to warm up. This is
displayed in the CO eld (9) and is incremented.

5
•The device requires an operating time of approx. 10 to 60 minutes for ameaningful
measurement. In small rooms (such as cupboards, drawers etc.) the operating time is
approx. 3to15minutes.
•Afrequent uctuation of the display is normal and shows the constantly repeated
measurements. The overall result is shown as the AQIvalue (3).
6. Air quality guidelines (AQI)
HCHO
mg/m³
0-0.080
0.081 -0.100
0.101 -0.200
0.201 -0.500 0.501 -1.000 1.001 -1.999
TVOC
mg/m³
0-0.5 0.5 -0.6 0.6 -1.5 1.5 -3.0 3.0 -6.0 6.0 -12.0
CO2
ppm
0-450 451 -1000 1001 -1500 1501 -2000 2001 -3000 3001 -5000
CO
ppm
0-5051-100 101 -200 201 -400 401 -800 801 -2400
AQI 01 02 03 04 05 06
Good Moderate Unhealthy
for sensitive
people
Unhealthy Very
unhealthy
Endangering
health
Specically by providing the value for the CO2 concentration in the air (8) ,conclusions
can be drawn about aerosols with viruses (e.g. Covid 19) present in the air.Although
these arenot directly detectable, increased CO2 pollution is at the same time a
measureofvirus-contaminated air.This can be remedied by regular airing.
Permanently inhaling bad and stale air can cause tiredness, headaches, eye irritation,
etc. The ability to perform and concentrate decreases noticeably as aresult.
The display of the concentrations of carbon monoxide (9),formaldehyde (7) and other
volatile compounds (2) also helps to ensurethat remedial action can be taken in good
time by means of ventilation. Furthermore, the different displays can help to identify the
corresponding sources: e.g. formaldehyde emissions from furniture, wood panelling,
etc. Respiratory diseases can thus be prevented and ahealthy indoor climate created.
7. Reset to factory settings (e.g. after relocation)
•Press and hold Reset (5) for around 3seconds to reset the product to the factory
default settings.
•All previous measurements arepermanently deleted.

6
8. Recalibration of the product
•Press and hold ANEW (6) for approximately 3seconds to recalibrate the product.
•Calibration should be carried out outdoors, as CO2 levels hereare usually around
400-450ppm.
•Please ensurethat thereisnoCO2 source in the immediate vicinity.Avoiddirect
sunlight and rain.
9. Care and maintenance
Note
Disconnect the device from the mains beforecleaning and during prolonged periods
of non-use.
•Only clean this product with aslightly damp, lint-free cloth and do not use
aggressive cleaning agents.
•Ensurethat no water is able to enter the product.
10.Warranty Disclaimer
The measuring device must not be used as awarning device for dangerously high
concentrations (e.g. industrial safety monitoring). It is not suitable for medical
institutions, certication or test measurements. The measuring device is primarily used
for testing purposes and for orientation in private households. No liability is accepted
for possible damage in case of malfunction.
It is not possible to transfer data via the USB cable.
Hama GmbH &CoKGassumes no liability and provides no warranty for damage
resulting from improper installation/mounting, improper use of the product or from
failuretoobserve the operating instructions and/or safety notes.
11. Technical data
Display mode LED digital display
Device dimensions 125 x80x35cm
Measurement error 3-30%
Pre-warming time after switch on 120 seconds
Operating voltage 5V min. 1A
Battery capacity 1000 mAh
Charging time Approx. 4hours
Standby Time Approx. 180-240 minutes

7
12.Recycling information
Note on environmental protection:
Following the implementation of European Directive 2012/19/EU and 2006/66/EU
into the national legal systems, the following applies: electrical and electronic
devices as well as batteries must not be disposed of with household waste.
Consumers areobliged by law to return electrical and electronic devices as well as
batteries to the designated public collection points or to the point of sale at the end of their
service lives. Detailed information on this topic is dened in the national laws of the
respective country.This presence of the above symbol on the product, operating instructions
or package indicates that the product is subject to these regulations. By recycling, reusing the
materials or other forms of utilising old devices/batteries, you aremaking an important
contribution to protecting our environment.

8
DBedienungsanleitung
1. Bedienungselemente und Anzeigen
1. Akku Ladezustand
2. TVOC: Flüchtige Organische Verbindungen in mg/m³ (Total Volatile Organic
Compounds). Kohlenstoffhaltige Stoffe, die bei niedriger Temperatur verdampfen.
Hygienisch inakzeptabel gelten Werte über 10 mg/m³. SpürbareAuswirkungen
sind Konzentrationsschwäche, Erschöpfung, trockene Haut bis hin zu Ekzemen oder
auch Kopfschmerzen.
3. AQI: Luft Qualitäts Index (Air Quality Index)
4. ON/OFF: Ein/Aus Taste
5. RESET: Datenbereinigung und neue Messung
6. ANEW: Gerätekalibrierung
7. HCHO: Formaldehyd Konzentration in mg/m³ (HCHO =CH₂O)
HCHO: Formaldehyd ist eine organisch-chemische Verbindung mit der
Summenformel CH₂O. Unter Standardbedingungen ist Formaldehyd ein Gas mit
einem stechenden Geruch. Formaldehyd kann nach Einschätzung der Europäischen
Union das Krebsrisiko steigern. Das Bundesinstitut für Risikobewertung (BfR) hat
die tolerierbareKonzentration für CH₂Ovon 0,1 ppm entspricht 0,124 mg/m³
festgelegt.
8. CO2: Kohlendioxid Konzentration in ppm (parts per million =
„Anteile proMillion“ =1Millionstel =1ppm =10
−6–entspricht 0,001 ‰)
Das Umweltbundesamt empehlt bei der Überschreitung eines Wertes von 1.000
ppm CO₂,frische Luft von draußen in den Raum zu lassen.
9. CO: Kohlenmonoxid Konzentration in ppm. In unbelüfteten Zimmern mit
Gasbrennern, Kaminen oder durch Zigarettenrauch werden schnell höhereWerte
erreicht. Steigt die CO-Konzentration auf Werte zwischen 136 und 280 ppm, treten
schon nach zwei bis drei Stunden Ermüdung, Schwindel, Übelkeit auf.Abeinem
Wert von 368 ppm wirdvon einer ungesunden Belastung gesprochen, höhere
Werte gelten als unmittelbar lebensbedrohlich.
10. Lüftungsöffnung
11. Ladebuchse
Vielen Dank, dass Sie sich für ein Hama Produkt entschieden haben!
Nehmen Sie sich Zeit und lesen Sie die folgenden Anweisungen und Hinweise zunächst
ganz durch. Bewahren Sie diese Bedienungsanleitung anschließend an einem sicheren
Ort auf,umbei Bedarf darin nachschlagen zu können. Sollten Sie das Gerät veräußern,
geben Sie diese Bedienungsanleitung an den neuen Eigentümer weiter.
2. Erklärung von Warnsymbolen und Hinweisen
Warnung
Wirdverwendet, um Sicherheitshinweise zu kennzeichnen oder um Aufmerksamkeit
auf besondereGefahren und Risiken zu lenken.
Hinweis
Wirdverwendet, um zusätzlich Informationen oder wichtige Hinweise zu
kennzeichnen.
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Sprachen:
Andere Hama Sicherheitssensor Handbücher