HDL BusPro SB-CMS-12in1 Bedienungsanleitung

Multi function Sensor
SB-CMS-12 in1
www.hdlautomation.com
User manual

User Manual
SB-CMS-12in1
Multi function Sensor–User Manual
INDEX
1. Overview....................................................................................................................... 1
1.1 General Information ............................................................................................. 1
1.1.1 Description................................................................................................. 1
1.1.2 Mounting.................................................................................................... 1
1.2 Functionnalities Description................................................................................. 2
1.3 Device Description............................................................................................... 2
2. Safety Instructions......................................................................................................... 3
3. Technical Data............................................................................................................... 3
4. Installation..................................................................................................................... 4
4.1 Wiring................................................................................................................... 4
4.2 HDL Bus Pro Description ..................................................................................... 4
4.3 Commissioning .................................................................................................... 5
5. Software Configuration.................................................................................................. 5
5.1 Basic setting......................................................................................................... 5
5.1.1 Change the ID of the device ...................................................................... 5
5.1.2 LED Indicators Settings ............................................................................. 6
5.2 IR Transmitter ...................................................................................................... 6
5.3 IR Receiver.......................................................................................................... 7
5.4 Sensors setting.................................................................................................... 8
5.4.1 Basic Info................................................................................................... 8
5.4.2 Constant Lux function................................................................................ 9
5.4.3 Adjust Lux Sensor...................................................................................... 9
5.5 Logic Relation...................................................................................................... 9
5.5.1 Logic Information ..................................................................................... 10
5.5.2 Further Settings of Current Logic..............................................................11
5.5.3 Relation.................................................................................................... 12
5.5.4 Trigger targets.......................................................................................... 12
5.5.5 Application ............................................................................................... 13
5.6 Security function ................................................................................................ 16
5.7 Relay Settings.................................................................................................... 16
5.7.1 NormalMode ............................................................................................ 17
5.7.2 Cycle Mode.............................................................................................. 17
5.7.3 Change Modes......................................................................................... 17
5.8 Simulate Test ..................................................................................................... 18
6. NOTES............................................................................................错误!未定义书签。

User Manual
SB-CMS-12in1
Multi function Sensor–User Manual 1
1. Overview
1.1 General Information
1.1.1 Description
12in1sensor includes temperature sensor, PIR motion sensor, LUX sensor, ultrasonic
sensor, dry contacts, IR received, IR emitter, 2CH 5A relay output and logic block. The
logic block can combine all sensors for different applications. It supports HDL security
function.
1.1.2 Mounting
Detect range
Celling mount Installation
34mm
110mm
85mm

User Manual
SB-CMS-12in1
Multi function Sensor–User Manual 2
1.2 Functionnalities Description
Temperature, Lux, IR motion, Ultrasonic, 2 dry contact input, 2 external inputs
2 logic relations: OR、AND
24 logic blocks function, maximum 9 logic inputs, up to 20 control targets in each logic
block
2CH 5A Relay output
Build PID for constant LUX control
Up to 40 IR receiving control targets
Up to 240 IR sending control targets
Maximum 24 programmable logic blocks
Security function, work with the security module
Supports upgrade from HDL BUS
1.3 Device Description
○
a. Programming button
○
b. Dry contact 1、2
○
c. HDL - Buspro
○
d. Relay output
○
e. Relay output
○
f. LUX sensor
○
g. Temp sensor
○
h. IR Emitter
○
i. PIR sensor
○
j . Ultrasonic sensor
○
k . Ultrasonic sensor
○
l .LED indicator
○
a
○
b
○
c
○
d
○
e
○
g
○
h
○
i
○
j
○
k
○
l
○
f

User Manual
SB-CMS-12in1
Multi function Sensor–User Manual 3
2. Safety Instructions
Screw down strength is less than 0.1Nm.
Do not make wrong connection on Bus interface, it will damage the Bus interface of
thismodule.
Do not get AC power into Bus wire, it will damage all devices in the system.
Avoid contact with liquids or corrosive gases.
3. Technical Data
Electric Parameters:
BUS power supply
DC12-30V
Static power consumption
40mA/DC24V
Dynamic power consumption
90mA/DC24V
Range of temperature sensor
-20℃to 60℃
IR transmit frequency
38KHz
IR emission distance
4m
Illumination detection range
0-5000Lux
PIR sensing range in diameter
6m (install height-3m)
Ultrasonic sensor in diameter
8m
Environmental Conditions:
Working temperature
0℃~45℃
Working relative humidity
40%~98%
Storage temperature
-20℃~+60℃
Storage relative humidity
10%~93%
Approved
CE
RoHS

User Manual
SB-CMS-12in1
Multi function Sensor–User Manual 4
Production information:
Dimensions
110(Diameter)×33(mm)
Weight
206.7(g)
Housing material
Lens, ABS
Installation
Ceiling mount
Protection degree
IP20
4. Installation
4.1 Wiring
HDL Buspro
4.2 HDL Bus Pro Description
Connector Information
buspro
DC24V
Red
COM
Black
DATA -
White
DATA +
Yellow

User Manual
SB-CMS-12in1
Multi function Sensor–User Manual 5
4.3 Commissioning
Method One:
a) open the HDL-BUS Pro Setup tool.
b) keep pressing the programming button for 3 seconds, it turns to red color.
c) on the software, click the “Address management”, and select the “Modify address
(when device button is pressed)”, it will show a window like this:
d) click the “Indicate initial address”, then it will show the ID of this device. If you want to
modify the address, fill in the new address, and click the “Modify initial address”. Click the
“+Add” button, the device will be add in “ON-line devices” list.
Method Two:
a) open the HDL-BUS Pro Setup tool.
b) click the search button, it will show a new window, click fast search button,search the
online devices. Click the “Add all”button, the devices which be searched will be added in
“ON-line devices” list.
5. Software Configuration
5.1 Basic setting
5.1.1 Change the ID of the device
Every HDL-BUS device has one Subnet ID and one Device ID, the Device ID should be
unique in its subnet and the Subnet ID should be kept consistent with the Gateway
(typically the SB-DN-1IP or HDL-MBUS01IP.431).

User Manual
SB-CMS-12in1
Multi function Sensor–User Manual 6
5.1.2 LED Indicators Settings
Enable or disable the PIR/Ultrasonic LED indicator. If enable, the LED indicator will turn
red when the PIR detects movement, or the same indicator will turn green when the
ultrasonic sensordetects movement.
5.2 IR Transmitter
12in1 has an IR (infrared) Transmitter, which can be used to control TV, DVD, AC (IR
controlled) etc, to replace your normal remotes.
You need an IR learnerto learn and upload the IR codes of your normal remote to the
12in1, also there are some codes have been stored in the HDL BUS setup tool, can view
them in „All IR Codes‟ window.
If now you want to upload some codes to the 12in1, e.g.HDL8 keys code, can follow these
steps:
a) input a range for the IR code ID, here is 1 to 8, click „Confirm‟
b) select „HDL8 Keys‟ in„All IR Codes‟ window, click „Upload‟, these codes will be shown in
„IR codes stored in the hardware‟ list, and the key status will change to „IR-Assigned‟.

User Manual
SB-CMS-12in1
Multi function Sensor–User Manual 7
Tips: when use buttons to control 12in1 to send out codes,set „key type‟ as universal
switch and set the parameter1(Switch no.) correspond to the UV switch number in 12in1,
and the parameter2(Switch Status) is ON.
Format IR Codes:All the IR codes in the 12in1 will be deleted.
Delete:Delete the IR code that is selected.
5.3 IR Receiver
Can send UV switch 249 „ON‟ command to enable the IR Receiver, or „OFF‟ to disable
from panel or other devices. Generally it works with HDL‟s IR/RFRemote Controller
(HDL-MTIRW), which has built-in HDL self-defined IR codes, can control HDL
panels/sensors directly, no need to learn IR codes.12in1 can support up to 5 pages, 40
keys in total.
For below setting, when press the first button in page 1, it will trigger the dimmer/relay(1-6)
to turn on/off channel1.

User Manual
SB-CMS-12in1
Multi function Sensor–User Manual 8
5.4 Sensors setting
5.4.1 Basic Info
- Remarks of dry contacts
Remarks are recommended, you may make remarks according to the installation places
- On-Site Status
You can check the real-time values of sensors by refreshing or enable „Update status
automatic‟
- Compensation
You can adjust the temp/lux sensors by giving them compensation values, according to
the environment of your installation place.
- Sensitivity
Give the PIR/Ultrasonic sensors proper sensitivity to avoid the wrong trigger
- Other Functions
Enable the conditions you need here, they are: dry contact1/2, UV switch 1/2 and logic
status as a condition
- UV Switch ID
The sensors and dry contacts have different UV switch ID, send the corresponding UV
Switch ID „ON‟ to enable it, and „OFF‟ to disable it from panel or other devices.
Inhaltsverzeichnis
Andere HDL Sicherheitssystem Handbücher
Beliebte Sicherheitssystem Handbücher anderer Marken

EDM
EDM Solution 6+6 Wireless-AE Bedienungsanleitung

Highway Safety Group
Highway Safety Group EA401 Bedienungsanleitung

Siren
Siren LED GSM Bedienungsanleitung

Detection Systems
Detection Systems 7090i Montageanleitung

Se-Kure Controls
Se-Kure Controls MicroMini SK-4841 Bedienungsanleitung

Siemens
Siemens FDM273 Bedienungsanleitung