HE-VA AC-LITE Bedienungsanleitung

1
HE-VA Auto-Controller
AC-LITE
Installation, Calibration and
Operation
Software Reference WZ704-000 rev.15
N. A. Christensensvej 34
DK-7900 Nykøbing Mors
Tel: +45 9772 4288
Fax:+45 9772 2112
www.he-va.com
Important:
Before using the machine,
please study the Operating
Instructions thoroughly to
ensure that you are familiar
with the safety instructions.
User Guide
Electro-Magnetic Compatibility (EMC)
This product complies with
Council Directive 89/336/EEC
when installed and used in accordance
with the relevant instructions.

HE-VA Auto-Controller AC-Lite - May 2016
2
1. Overview____________________________________ 4
1.1 Programming Modes.....................................................................................4
2. Installation __________________________________ 5
2.1 The Head Unit ...............................................................................................6
2.2 The ‘Tractor Terminator’ Assembly................................................................7
2.3 Power supply.................................................................................................8
2.4 Radar sensor.................................................................................................8
2.5 Cutout switch.................................................................................................9
3. Normal Operating Mode ______________________ 10
3.1 Operating Summary ....................................................................................10
3.2 Power On/Off...............................................................................................11
3.3 Work Status Indicator..................................................................................11
3.4 Starting and Stopping the Seeding..............................................................11
3.5 Pre-start function.........................................................................................11
3.6 Cutout Alarm................................................................................................12
3.7 Simulated Speed.........................................................................................12
3.8 Application Rate –kg/ha or seeds/m²..........................................................12
4. Forward Speed Display_______________________ 13
4.1 View Forward Speed...................................................................................13
4.2 Minimum Speed Alarm................................................................................13
4.3 Speed Sensor Calibration............................................................................13
4.4 ‘Autocal’ Speed Calibration .........................................................................14
5. Area Display________________________________ 15
5.1 View Area Totals .........................................................................................15
5.2 Zero Area Total............................................................................................15
5.3 Set Implement Width...................................................................................16
6. Drilling Rate Functions _______________________ 17
6.1 View Drilling Rate........................................................................................17
6.2 Adjusting the Drilling Rate ...........................................................................17
6.3 Drilling Rate Indicator ..................................................................................17
6.4 Changing the Target Rate...........................................................................18
6.5 Product Calibration......................................................................................19
6.6 Set % Step for Rate Offset..........................................................................20

HE-VA Auto-Controller AC-Lite - May 2016
3
7. Hopper level Alarm___________________________21
7.1 Feed roll monitoring………………………………………………………………21
8. Fan Speed / Speed Alarms ____________________21
Display Fan Speed .................................................................................................21
Fan Speed Alarms..................................................................................................21
Set Low Fan Speed Alarm......................................................................................22
9. Programme Functions and Fault Diagnosis ______23
9.1 Programme (CAL) Modes 1 –5 ...................................................................23
9.2 Fault Diagnosis ............................................................................................24
10. Calibration Record___________________________25

HE-VA Auto-Controller AC-Lite - May 2016
4
1. Overview
The HE-VA Auto-Controller enables fully automatic control of the seed rate of
HE-VA Multi-Seeder.
The HE-VA Auto-Controller automatically maintains a preset application rate as
forward speed varies, with on-the-go adjustment of rate.
The instrument measures and indicates:
Forward Speed
Part Area and Total Area worked
Seed Application Rate (kg/ha)
Low Hopper Level
There are also audible and display alarms for,
Minimum / maximum forward speed (beyond which the programmed seed rate
cannot be maintained).
Feed motor stopped (no feedback)
Feed motor stalled
The head unit is powered on and off via a toggle switch on the rear of the instrument.
A pushbutton switch in the cab is used to manually switch the feed motor on and off.
The feed motor is also switched on and off automatically via the implement-mounted
cutout finger switch as the implement is raised and lowered.
Area totals and all calibration data are automatically stored in memory when the
instrument is powered off.
The system must be initially calibrated for the seed being applied. Seed calibration is
very simple to undertake via a priming switch provided on the junction box fitted on the
Multi-Seeder.
1.1 Programming Modes
There are 5 programming modes with various calibration factors and default settings.
Access to the programming modes is required for some settings that may be changed
as part of the normal operating procedure. Changing these settings is described with
the operation instructions (sections 4,5,6,7 and 8).
Other settings are made on installation and do not normally need to be changed.
These settings are appended to in the back of this manual (section 9). The operator
does not normally need to refer to them.
NOTE: The instrument front panel appearance may be slightly different to that illustrated.

HE-VA Auto-Controller AC-Lite - May 2016
5
2. Installation
Figure 1
Head Unit
Manual
Cutout
Switch
Power supply
Junction Box
Assy
View on side of J/Box
- ‘Prime’ button
Automatic
Cutout Switch
Radar Sensor
TJ237
(shown as fitted on Multi-Seeder, but
can be fitted on tractor and wired into
Tractor Terminator Box)
Hopper Level
sensor
Feed Motor
Tractor Terminator
Assy
Extension cable

HE-VA Auto-Controller AC-Lite - May 2016
6
2.1 The Head Unit
Confirm with the operator on where to mount the head unit in the cab. It must not
restrict the view out of the cab, nor impede the use of the controls. The head unit is
fitted with a 1-metre flying lead terminating with an 8/10-way IDC type connector, ready
for connection into the "Terminator" junction box.
The head unit is supplied with mounting kit ref: TJ235 comprising the following parts
(fig. 2):
1 Long Bracket
1 Short Bracket
3 Clamping Knobs
1 Cover Plate
1 Mounting Plate
2 Self Tapping Screws
1. Snap the cover plate into the recess of the long
bracket (it only fits one way).
2. The instrument mount is designed to offer maximum
flexibility in positioning the head unit, either from the
right hand side of the cab, from the dashboard or
from an overhead position.
3. Assemble the two brackets, and mounting plate with
clamping knobs, and attach to the head unit.
NOTE: Either the long or short bracket can be
attached to the head unit, whichever gives the
most suitable orientation.
Having established the orientation for the
bracket, fix the mounting plate to the cab
with the self-tapping screws provided.
Do not drill into a ROPS or FOPS frame.
If you are fixing the mounting plate to plastic e.g. the dashboard or other cab moulding,
it is recommended to use M4 screws with mudwing washers to strengthen the
mounting point.
Do not attempt to adjust the mounting bracket assembly without first
slackening off the clamping knobs sufficiently. You will only succeed in
damaging the bracket otherwise.
Figure 2 : Head Unit Mounting Kit

HE-VA Auto-Controller AC-Lite - May 2016
7
2.2 The ‘Tractor Terminator’ Assembly
Mount the pushbutton Cutout Switch in a convenient position using 2 self-tapping
screws.
Remove the lid of the terminal box by squeezing the sides and connect the head unit
lead as shown in figure 3 below.
The Terminator is not a waterproof enclosure. Locate it where it is afforded protection
from possible water ingress and for neatness e.g. behind a trim panel or console.
Figure 3: Head unit connection
NOTE: The head unit receives its power supply via the junction box (see figure 1).
The power supply terminals in the Terminator are not used.
The circular (CPC) connector trails to the back of the tractor to connect with the 6-
metre extension lead going to the junction box.
10-way connector
to PL1
(RED wire)
8-way connector
to PL2
(RED/BLUE wire)

HE-VA Auto-Controller AC-Lite - May 2016
8
2.3 Power supply
The system is powered via the three pole plug/connector.
2.4 Radar sensor
The radar sensor may be fitted either to the Multi-Seeder or to the tractor. For fitting
instructions please refer to the separate instruction leaflet ref. S/DC/500-10-511
provided.
Connecting a Multi-Seeder-mounted radar sensor:
Simply connect the radar sensor lead to the lead from the junction box
(3-way connector). Coil any excess lead near the junction box and secure
the lead from the sensor at regular intervals using the cable ties provided.
Connecting a tractor-mounted radar sensor:
Open the junction box and remove the sensor extension lead with the
3-way connector (fig. 4). Plug the hole to prevent water ingress.
Figure 4
Connect the extension lead to the sensor and route back to the Terminator junction
box. Where possible follow the existing wiring loom and secure at regular intervals
using the cable ties provided.
Remove the lid of the terminal box by squeezing the sides, cut off excess cable length
and connect the head unit lead as shown in figure 5.
Remove the radar
sensor lead

HE-VA Auto-Controller AC-Lite - May 2016
9
Figure 5
The default speed sensor calibration factor (SSF) programmed in the head unit =
‘7.78’ (millimeters/pulse). This is theoretically correct for the radar sensor when it is
installed at exactly the specified angle to the ground. Often though, the sensor may
not be exactly at the prescribed angle. It is therefore recommended that to ensure
accurate speed measurement, you check the calibration value by performing an
‘Autocal’ procedure (please refer to section 4.4).
2.5 Cutout switch
The implement-mounted cutout finger switch enables the system to automatically start
and stop operation as the implement is lifted and lowered.
It therefore needs to be mounted in a suitable position to operate as the implement
enters work.
NOTE: For fitting instructions please refer to the separate instruction leaflet
ref. S/DC/500-10-121 provided.
1 Brown (+V)
2 Blue (0V)
3 Yellow/Green (Sig)

HE-VA Auto-Controller AC-Lite - May 2016
10
3. Normal Operating Mode
3.1 Operating Summary
Press to select
the Display
Function
Decrease
Rate
Channel
Indicator
Increase
Rate
EITHER:
1. View Area Total
Select the (Area Total)
channel, then press the CAL
button to switch between Area
Total 1 and Area Total 2.
OR:
2. HOLD continuously for 10
seconds to enter
CAL Mode 1 / CAL Mode 2
(Normal Mode is resumed
when the button is released).
CH Function Units
1 Forward Speed km/h
2 Area Total 1 or 2 ha
3 (No function) -
4 Seed Rate kg/ha
5 (No function) -
6 Hopper level Status -
These channels have different functions when
the instrument is in Programme (CAL) Mode 1,
2, 3, 4 or 5.
With Area display
selected, press and
HOLD for 5 secs to zero
the selected area total
or,
HOLD whilst powering
on to enter CAL Mode 3
Target rate
Indicator