5
14. WARNING: Avoid any drafts that alter burner flame patterns. Do not allow fans to blow directly
into fireplace. Do not place a blower inside burn area of firebox. Ceiling fans may create drafts
that alter burner flame patterns. Sooting and improper burning will occur.
15. Caution: Candles, incense, oil lamps, etc. produce combustion by-products including soot.
Vent Free heaters will not filter or clean soot produced by these types of products. In addition,
the smoke and/or aromatics (scents) may be reburned in the vent free heater which can
produce odors. It is recommended to minimize the use of candles, incense, etc. while the vent
free heater is in operation.
16. Keep room area clear and free from combustible materials, gasoline and other flammable
vapors and
liquids.
17. This appliance is intended for supplemental heating.
18. Unvented gas heaters emit moisture into the living area. In most homes of average
construction, this does not pose a problem. In houses of extremely tight construction,
additional mechanical
ventilation is recommended.
19.
Duringmanufacturing,fabricatingandshipping,variouscomponentsofthisheaterare
treatedwith
certainoils,filmsorbondingagents.Thesechemicalsarenotharmfulbutmay
produceannoying
smokeandsmellsastheyareburnedoffduringtheinitialoperationofthe
heater;possiblycausing headachesoreyeorlungirritation.Thisisanormalandtemporary
occurrence.Theinitialbreak-in
operationshouldlastfourtosixhourswiththeburneratthe
highestsetting.Providemaximum
ventilationbyopeningwindowsordoorstoallowodorsto
dissipate. The amount of time required for the initial break-in is dependent on a number of
variables determined by your specific installation including but not limited to surfaces and
surface finishes adjacent to the fireplace which may off gas for some period of time.Any
odorsremainingafterthis
initialbreak-inperiodwillbeslightandwilldisappearwith
continueduse.
20. Input ratings are shown in BTU per hour and are for elevations up to 2,000 feet. If your
installation
is at an elevation greater than these, consult with the local authority having
jurisdiction for gas
product installations to determine their specific requirements for high
altitude installations.
21.
The heatermustbe isolated from the gas supply piping system byclosing its equipment
shutoff
valveduringanypressuretestingofthe gas supply piping systemattestpressures
equaltoorless
than
1/2
psi(3.5kPa).
22. Do not use this room heater if any part has been under water. Immediately call a qualified
service technician to inspect the heater and to replace any part of the control system and any
gas control
which has been under water.
23. Never burn solid fuels in a fireplace where an unvented heater is installed.
24. WARNING: Any change to this heater or its controls can be dangerous.