Hekatron FSZ Basis Bedienungsanleitung

2

3
Contents
1 General safety information and protective measures ......... 5
2 Scope of delivery ...................................... 6
3 Warranty ............................................ 6
4 Product description .................................... 7
5 FSZ Basis – technical data ............................... 8
6 Current requirements .................................. 9
7 Installing the FSZ Basis ................................ 10
8 FSZ Basis – applications ................................ 11
9 Electrical installation .................................. 12
9.1 Installation instructions ........................................ 12
9.2 Control unit FSZ Basis for hold-open systems ....................... 14
9.3 Termination module AM 142 .................................... 16
9.4 FSZ Basis – operation ........................................... 17
9.5 Hold-open system according to DIN EN 14637 ....................... 19
9.6 Connection configurations according to DIBt and DIN EN 14637 ........ 20
9.7 Signalling of the FSZ Basis ...................................... 27
10 Commissioning and acceptance ......................... 30
10.1 Acceptance testing ............................................ 30
10.2 Maintenance instructions ....................................... 31
10.3 Monthly functional test ........................................ 31
10.4 Annual testing and maintenance ................................. 31
10.5 Functional test ............................................... 32

4
11 Maintenance ........................................ 33
11.1 Obligatory documentation requirement ........................... 33
12 Annex ............................................. 34
12.1 Order data ................................................... 34
12.2 Drilling template ............................................. 34
12.3 Technical support and application support ......................... 34

5
1 General safety information and protective measures
1 General safety information and protective measures
The present documentation describes the function of the FSZ Basis with the hardware and software
version applicable at the date of issue of this document.
Information for Germany
The test regulations of the Deutsches Institut für Bautechnik and the respective type approval must
be observed and followed while projecting, assembling, installing and operating hold-open systems
on fire barriers.
The information contained in this Instruction Manual is based on these regulations.
Ensure proper use!
– The technical data specified for the equipment must be observed.
– Modifications or changes to the equipment are not permitted.
– The equipment must be used only for its intended purpose in an undamaged and perfect condition.
– No other spare parts than those available from the manufacturer must be used.
– The allowed components of the hold-open system are listed in a separate type approval.
Hold-open systems are subject to the duty of servicing required according to DIN 31051 and DIN 14677.
More information can be found in the respective type approval document of the hold-open system.
If the use of the system is changed, it must be verified whether the legal provisions, requirements
and state of the art are appropriately taken into account.
Specialised staff must be provided for projecting, assembling and commissioning.
When working on electrotechnical installations, special regulations must be complied with.
Such work may only be carried out by authorised qualified electricians.

6
2 Scope of delivery
2 Scope of delivery
On delivery, the FSZ Basis features the following components:
1 x FSZ Basis
1 x instruction manual
1 x assembly kit consisting of 2 screws and 2 dowels
1 x cable gland kit consisting of:
- one M20 cable gland for the power supply cord
- three M16 glands for connection of the peripheral equipment,
e.g. ORS 142, electromagnetic door retainers, etc.
1 x module for the integrated release button,
labelled “Tür schließen” (Close door) and “Tor schließen” (Close gate)
1 x termination module AM 142 (only for version 31-5400002-01-xx and 31-5400002-05-xx)
3 Warranty
In case of non-compliance with the information contained in this Instruction Manual, any claims for
guarantee and liability of the manufacturer will become invalid. In particular, the device or its com-
ponents may only be repaired by authorised personnel. It is not allowed to dismount or manipulate
the device. If the device is manipulated nevertheless, any warranty claims become void.
The information and warranty conditions in the general terms and conditions of
Hekatron Vertriebs GmbH, Brühlmatten 9, D-79295 Sulzburg, shall apply.

7
4 Product description
4 Product description
The hold-open control unit, FSZ Basis, is preferably used to supply hold-open systems with voltage.
It is characterised by the following features:
– Integrated manual release button conforming to standard and reset button
– Tested according to DIN EN 14637
– Distinction between fault causes via the LED flash code on the keypad
– Alarm storage can be activated via DIP switch
– Line surveillance can be activated via DIP switch
– Two smoke switch stubs can be connected with activated line surveillance
– Relay with potential-free alternating contact at the user‘s free disposal
– Short-circuit-proof primary pulsed switching power supply unit with stabilised output voltage
– Power supply with overtemperature shutdown

8
5 FSZ Basis – technical data
5 FSZ Basis – technical data
Nominal voltage 230 V AC
Nominal current consumption 0.08 A eff.
Rated frequency 50/60 Hz
Power consumption 13.8 VA
Nominal output voltage 24 V DC
Residual ripple 200 mVSS
Output current max. 400 mA
Output power 9.6 W
Relay
Switching voltage AC
Switching current AC
Switching voltage DC
Switching current at 30 V DC
Switching current at 24 V DC
1 alternating contact, potential-free
max. 250 V AC
max. 5 A AC
max. 30 V DC
max. 3 A DC
max. 5 A DC
Operating ambient temperature -10 °C to +50 °C
Storage temperature -10 °C to +60 °C
Ambient conditions humidity
(continuous, without condensation) ≤34 °C
10 ... 95 % RH
Ambient conditions humidity
(continuous, without condensation) > 34 °C
max. 35 g/m³
min. 10 % RH
Degree of protection with exposed assembly IP 65
Degree of protection with cable entry from behind IP 30
Safety class "I"
Housing PC-ABS housing
Colour signal white according to RAL 9003
Installation exposed assembly
Installation position as desired

9
6 Current requirements
Cable entries 6 x M16 and 2 x M20
Dimensions HxWxD 146 mm x 146 mm x 60.5 mm
Weight 420 g
DIBt approval Z-x.x-xxxx
VdS approval according to DIN EN 14637 G 213091
6 Current requirements
The FSZ Basis provides a total output current of 400 mA. This output current can be completely
used for the required components of the hold-open system. The current required for the hold-open
system consists of the sum total of all currents of the components connected.
Example calculation:
The hold-open system comprises the following components:
Smoke switch 3 x ORS 142 3 x 22 mA 66 mA
Electromagnetic door
retainer
2 x THM 425 2 x 63 mA 126 mA
Total current requirements 192 mA
The total current must not exceed 400 mA. The current consumption of the various components of
the hold-open system is specified in the related product documents.

10
7 Installing the FSZ Basis
7 Installing the FSZ Basis
The safe installation of the FSZ base requires only 2 holes (see annex drilling template). The FSZ
Basis is therefore delivered including two screws and dowels.
The installation position can be selected as desired. The FSZ accessories kit – which must be ordered
separately – includes two mounting adapters for installation of the FSZ Basis in a switch cabinet or
on a top-hat rail. The mounting adapters can be mounted on the rear of the FSZ Basis at the points
provided.
Mounting points for top-hat rail adapter
Fig. 1: Mounting points for top-hat rail adapter
Inhaltsverzeichnis
Andere Hekatron Steuereinheit Handbücher
Beliebte Steuereinheit Handbücher anderer Marken

Festo
Festo Compact Performance CP-FB6-E Stücklistenhandbuch

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Bedienungsanleitung

JS Automation
JS Automation MPC3034A Bedienungsanleitung

JAUDT
JAUDT SW GII 6406 Series Kurzanleitung

Spektrum
Spektrum Air Module System Bedienungsanleitung

BOC Edwards
BOC Edwards Q Series Bedienungsanleitung