Heritage Bathrooms SDC04 Montageanleitung

Installation Instructions
and User Guide
Thermostatic Recessed
Dual Control Shower
Valve
Models covered: SDC04, SDA04, SOC10,
SGC03, SGA03, SHDC02 & SHDA02
Please keep this booklet for future
reference.
Installer, when you have read these in-
structions please ensure you leave them
with the user.
www.divapor.com

Thank you for choosing Heritage, the UK’s market leader for classic bathroom products. To
ensure this product works to its full potential, it needs to be tted correctly. These tting
instructions have been created to give you all of the information you need. If you need any
further help, please do not hesitate to give us a call on 0844 701 8503.
Important Safety Information
General Information
Product Features
Specications
Pack Contents
Prior to Installation
Installation
Shower Valve
Wall Outlet
Shower Kit
Operating the Shower
Maintenance
Adjusting the Temperature
Troubleshooting
Notes
Guarantee
Contents
2 Need help? Give us a call on 0844 701 8503 and speak to one of our trained advisers.
3
4
5
6
7-11
12
13-17
14-14
15
16-17
18
19
20
21-22
23-25
26-27
www.divapor.com

Important Safety Information
Need help? Give us a call on 0844 701 8503 and speak to one of our trained advisers. 3
• Please read these instructions thoroughly and retain for future use.
• All products manufactured and supplied by Heritage are safe provided they are installed, used
correctly and receive regular maintenance in accordance with these instructions.
• If you are in any doubt about your ability to install this product safely you must employ the
services of an experienced qualied plumber.
• These ttings need to be installed in accordance with, and meet the requirements of
the Water Supply (Water Fittings) Regulations 1999 and Scottish Byelaws 2004.
• Remove all packaging and check there are no missing or damaged parts.
• Before starting any installation please consider the following:
• Before drilling into walls, check that there are no hidden electrical wires, cables or water
supply pipes.This can be checked with the aid of an electronic detector.
• If power tools are used do not forget to: - Wear eye protection
- Unplug equipment after use
• Warning: Before installing the new shower valve it is essential that you thoroughly ush
through the pipework in order to remove any remaining swarf, solder, etc. Failure to carry out
this procedure could cause problems or damage to the workings of the shower valve.
• Fitting isolation valves to the inlet feeds is required for ease of maintenance.
• Access must be made available to the shower valve / mixer body for maintenance / servicing
purposes.
• Do not block the ow of water from the showerhead, by placing it (smothering it) on you
hand or any other part of your body or foreign object.
• Do not crush or kink the shower hose, this could damage the hose and cause leaks.
• Warning: Do not operate this product if you suspect it is frozen. Do not site the Mixing
Valve where it might be subjected to freezing conditions.
• These shower valves must not be modied in any way as this will invalidate the guarantee.
www.divapor.com

General Information
Recommended Usage
Domestic Heavy
Commercial
Light
Commercial Health Care
This product has been tested to the Water Regulations Advisory Scheme (WRAS) and satises
the requirements of the Water Supply (Water Fittings) Regulations 1999 and current bylaws.
For full Installation Requirements & Notes (IRN) please visit www.wras.co.uk/directory.
BS7600 recommends the temperature of stored water should never exceed 65ºC.A stored
water temperature of 60ºC is considered sufcient to meet all normal requirements and will
minimise the build up of lime scale in hard water areas.
If the shower valve is installed at low pressure (tank fed), then the minimum distance from the
highest installed position of the showerhead to the underside of the cold tank should be at
least 1 metre to ensure adequate performance.
Note: Nominally equal (balanced) inlet supply pressures are recommended for optimum
performance.
This shower valve should be installed in compliance with the Water Supply (Water Fittings)
Regulations1999 and the Scottish Bylaws 2004.
If in doubt, contact a registered plumber or your Local Water Authority or the Secretary of
The Institute of Plumbing, address as follows;-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB
Tel: 01708 472791
4 Need help? Give us a call on 0844 701 8503 and speak to one of our trained advisers.
www.divapor.com

Product Features
1. On / off control
Turn the handle clockwise to turn on and
increase the ow of water.
Turn the handle anti-clockwise to turn off the
ow of water.
2. Temperature control
Adjustable temperature control.
Turn the handle clockwise for a cooler tem-
perature.
Turn the handle anti-clockwise for a hotter
temperature.
Note: The SDC04 & SDA04 can either be
installed portrait or landscape.
1
2
SOC10 shown
Need help? Give us a call on 0844 701 8503 and speak to one of our trained advisers. 5
www.divapor.com

Specications
Inlet connections: 15mm compression with 150mm between centres.
Minimum working pressure: 0.2 bar
Note: This product has been designed to deliver a high ow of water on low pressure
systems, however depending on the installation, type of system and shower accessories used, a
higher pressure maybe required to optimise the showering experence.
Maximum working pressure: 5 bar
Maximum static pressure: 10.0 bar
Note: Static pressure is the build up of pressure when the valve is closed.
Supply requirements:
Minimum cold water supply temperature: 5ºC.
Maximum cold water supply temperature: 25ºC.
Maximum hot water supply temperature: 80ºC.
Note: The inlet hot water temperature must be at least 10ºC above the required blend
temperature (e.g. shower temperature 43ºC: minimum hot water temperature 53ºC).
System requirements:
Gravity fed hot & cold (Equal pressures)
Gravity fed hot & mains cold (Differential pressure, maximum ration 5:1)
Unvented systems
Instantaneous water heater (Combination boiler)
Pumped system
Note: When using a pumped system we recommend that an essex flange is used.
Important: Minimum wall cavity depth: 35mm
Min - Max Concealing plate thickness: 45-75mm
For full dimensional drawings please visit www.heritagebathrooms.com
6 Need help? Give us a call on 0844 701 8503 and speak to one of our trained advisers.
www.divapor.com

Pack Contents - SDC04 & SDA04
1. Concealing plate x1
2. Handles x2
3. Shrouds x2
4. Screws x2
5.Valve body x1
6. Valve body xings x2/2
7. Inserts x2
8. Flow regulators x2
9. Filter washers x2
10.Wall outlet x1
11. Shrouds x2
1
2
3
4
5
6
7
8
9
10
11
Need help? Give us a call on 0844 701 8503 and speak to one of our trained advisers. 7
www.divapor.com

Pack Contents - SOC10
1. Concealing plate x2
2.Valve body x1
3. Handles x2
4. Spline adaptors x2
5. Valve body xings x2/2
6. Inserts x2
7. Flow regulators x2
8. Filter washers x2
9.Wall outlet x1
10. Shrouds x2
1
2
3
4
5
6
7
8
9
10
8 Need help? Give us a call on 0844 701 8503 and speak to one of our trained advisers.
www.divapor.com

Flow Regulators
This shower valve is supplied with a 5 and 7
litre per minute ow regulator loose in the
box which must be tted if the shower valve
is installed in conjunction with an instantane-
ous water heater / combination boiler.
With both ow regulators tted and by
turning the water heater / combination boiler
to its hottest setting, will ensure a sufciently
hot water supply to the shower valve during
winter months (in the UK), when the mains
cold water supply is at its coldest.
To t the ow regulators
Remove the inlet elbows ensuring the lter
washer is also removed. carefully remove the
plastic inserts from the valve inlets and push
in the ow regulators. The 7 litre per minute
green ow regulator must be tted to the
cold inlet and the 5
litre per minute yellow ow regulator must
be tted to the hot inlet.
Place the lter washers back into the elbow
nuts and tighten the nuts fully onto the
outlets.
In the event that this shower valve is not
installed with an instantaneous water heater /
combination boiler, the ow
regulators do not need to be tted.
Prior to Installation
Flow
Regulator
Insert
Elbow
Filter
Washer
Need help? Give us a call on 0844 701 8503 and speak to one of our trained advisers. 9
www.divapor.com

Installation - Shower Valve
nut
Elbow
Important: Water supplies to the mixer
must be with hot on the left and cold on the
right when viewed from the front.
Wall plugs
Fixing
screws
This shower valve is designed for
installations where a recessed valve is already
installed in the wall cavity and is to be re-
placed, or for new installations.
Before Installation
Flush through the pipework to ensure re-
moval of any debris.Turn off the mains water
supply and close any isolating valves.
1.Attach shower valve to wall
Place the shower valve in the required posi-
tion and mark the centres of the xing holes
onto the wall.
Warning: Please check for any hidden
pipes and cables before drilling holes in the
wall.
Drill suitable holes and insert the wall plugs.
Securely attach the shower valve to the wall
using the screws supplied.
2.Connect water supply pipes
Insert 15mm hot and cold water supply pipes
into the inlet connections and
tighten nuts, ensuring the olives are tted.
3. Plumb in outlets
Insert 15mm pipework into the top outlet
and plumb into the users chosen
products. Ensure the olives are tted when
tightening the nuts.
10 Need help? Give us a call on 0844 701 8503 and speak to one of our trained advisers.
www.divapor.com
Dieses Handbuch passt für folgende Modelle
6
Inhaltsverzeichnis
Andere Heritage Bathrooms Steuereinheit Handbücher
Beliebte Steuereinheit Handbücher anderer Marken

Festo
Festo Compact Performance CP-FB6-E Stücklistenhandbuch

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Bedienungsanleitung

JS Automation
JS Automation MPC3034A Bedienungsanleitung

JAUDT
JAUDT SW GII 6406 Series Kurzanleitung

Spektrum
Spektrum Air Module System Bedienungsanleitung

BOC Edwards
BOC Edwards Q Series Bedienungsanleitung
















