HIK VISION DS-k2210 Bedienungsanleitung

1
2
Main Elevator Controller
Quick Start Guide
UD03825B-C
Appearance
Installation
Wiegand Terminal
Ethernet
Port
DIP Switch
Power Input Tamper-Proof
Interface
Linkage Output
Terminal
Before you start:
The minimum bearing weight of the wall or other places should be three mes heavier than the device weight.
Dial-up before you install.
RS-485 Terminal
Relay Output
Terminal
IO Input Terminal
Orange&White OK
Orange ERR
Green&White BEEP
Blue W1
Blue&White W0
Green / Brown&White GND
Brown 12V
Indicator
Power On: Solid Green
Status: Normal (Flashing Green)
Exception (Solid Red)
RS-485: No Communication (Off)
Communication (Solid Green)
Relay: Disconnected (Off)
Connected (Solid Green)
Network: Disconnected (Off)
Connected (Solid Yellow, Flashing Green)
Armed (Solid Yellow, Flashing Green)
166.95
29.5
101
105
Wall
Guide Rail
Screw Socket
Screw
Device
Wiegand Sequence
Network Cable
Input
Linkage Output
Power StatusRelay Output
GND Thread
Interface
Dimensions (mm)
Steps:
1. Drill holes on the wall or other places according to the holes on the guide rail.
2. Insert the screw sockets of the set screws (supplied) in the drilled holes.
3. Secure the guide rail on the wall or other places with the screws (supplied).
4. Push the device to the guide rail and fix it.
©2020 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
It includes instrucons on how to use the Product. The soware embodied in the Product is
governed by the user license agreement covering that Product.
About this Manual
The Manual includes instrucons for using and managing the Product. Pictures, charts, images and
all other informaon hereinaer are for descripon and explanaon only. The informaon
contained in the Manual is subject to change, without noce, due to firmware updates or other
reasons. Please find the latest version of this Manual at the Hikvision website (hps://www.hikvi-
sion.com/).
Please use this Manual with the guidance and assistance of professionals trained in supporng the
Product.
Trademarks
and other Hikvision’s trademarks and logos are the properes of Hikvision in various
jurisdicons.
Other trademarks and logos menoned are the properes of their respecve owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT
DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND
“WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A
PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT
WILL HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT
DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS
INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF SYSTEMS, OR LOSS OF DOCUMENTATION,
WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT
LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION
HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY
RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION,
PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER-ATTACK, HACKER ATTACK, VIRUS
INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY
TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE
SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW.
ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS PRODUCT IN A MANNER THAT DOES NOT
INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF
PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS.
YOU SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOP-
MENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR
PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT
RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF
HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER
PREVAILS.
Data Protecon
During the use of device, personal data will be collected, stored and processed. To protect data,
the development of Hikvision devices incorporates privacy by design principles. For example, for
device with facial recognion features, biometrics data is stored in your device with encrypon
method; for fingerprint device, only fingerprint template will be saved, which is impossible to
reconstruct a fingerprint image.
As data controller, you are advised to collect, store, process and transfer data in accordance with
the applicable data protecon laws and regulaons, including without limitaon, conducng
security controls to safeguard personal data, such as, implemenng reasonable administrave and
physical security controls, conduct periodic reviews and assessments of the effecveness of your
security controls.
Scan the QR code to get the user manual for detailed informaon.
Note that mobile data charges may apply if Wi-Fi is unavailable.

Device Wiring
3
Power InputLinkage Output
Terminal
RS-485 TerminalRelay Output Terminal
Reserved
Loop
Uplink RS-485
Device
Relay 1 (NC)
A+ A- GND A+ A- GND
Distributed
Controller
RS-485 Card Reader
Linkage Input Terminal of
Distributed Elevator Controller
When the panic button, the maintenance button, fire alarm button,
and the event alarm are triggered, the main elevator controller will
control the distributed controller via the linkage output to perform
the linked actions.
Each main elevator controller supports up to 24 distributed
elevator controllers, including 8 call elevator distributed
controllers, 8 auto button distributed controllers, and 8
button distributed controllers.
When the panic button is triggered, all relays keep connected. It is
valid for all floors.
When the fire alarm button is triggered, all relays keep disconnected.
It is invalid for all floors.
When the maintenance button is triggered, all relays keep discon-
nected. It is invalid for all floors.
Activation
1. Click Device Management icon to enter the Device Management interface.
2. Select an inacve device from the device list. Click Acvate to pop up the Acvaon interface.
3. Create a password and confirm the new password. Click OK to start acvate.
4. Click “Edit Network” to configure the device IP address, mask address, gateway address, port No.
1. Input the device IP address in the address bar.
For the first login, the web client will enter the activation interface.
The device default IP address: 192.0.0.64
2. Input the user name and the password according to the tips in the interface.
3. Confirm the password.
Activating Device via Client Software
Activating Device via Web Client
4
1. Download SADP Soware:
Get the SADP soware from the supplied disk or the official website. Install and run the soware.
2. Acvate Device:
Check the inacve device from the device list. Create a password in the right side of the interface and confirm the password.
3. Edit Device IP Address:
Check the device and manually edit the device IP address, Port No., Subnet Mask, Gateway, etc.
Activating Device via SADP Tool
Activating via the Web Client, the SADP tool, and the client software are supported.
Total number of online devices:
ID
001 XXXXXXXXXXXXXX XXXXXXXXXXXXXX
XXXXXXXXXXXXXX
XXXXXXXXXXXXXX
You can modify the network parameters aer
the device acvaon.
Acvate Now
New Password:
Confirm Password:
Acvate
VXXXXXXXXXXXXX
VXXXXXXXXXXXXX
VXXXXXXXXXXXXX
XX.XX.XX.XX XX.XX.XX.XX
XX.XX.XX.XX
XX.XX.XX.XX
XX
Export Fresh Acvate the Device
The device is not acvated.
XX
XX
XX
XX
XX
XX.XX.XX.XX
XX.XX.XX.XX
Acve
Acve
Inacve
XXXXXXXXXXXXXX
XXXXXXXXXXXXXX
002
003
Device Type Security IPv4 Address Port Soware Version IPv4 Gateway HTTP Port Device Serial No.
3
Shielded Twisted Pair External Power
……
Distributed Controller Cascading
IO Input
Relay Output Linkage Output
Power Status
Relay 2 (NO) Distributed
Controller
Device
12V
Power
12V
Power
2
Wiegand Terminal
Network Interface
IO Input
Panic Buon
Maintenance
Buon
Wiegand Card Reader 1
Fire Alarm
Buon
Event Input 1
Event Input 2
Connect to Ethernet
Wiegand Card Reader 2
Online Device(2)
Add to Client
IP
xx.xx.xx.xx xxxxxxxxxxxxx xxxxxxxxxxxxx xxxx-xx-xx xx:xx:xx8000Active
Device Type Firmware Version PortSecurity Start Time
Modify Netinfo Activate Filter
Refresh Every 60s
xx.xx.xx.xx xxxxxxxxxxxxx xxxxxxxxxxxxx xxxx-xx-xx xx:xx:xx8000Inactive
Add All Device Reset Password
Regulatory Information
FCC Information
Please take aenon that changes or modificaon not expressly
approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found
to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide
reasonable protecon against harmful interference in a
residenal installaon. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in
accordance with the instrucons, may cause harmful interference
to radio communicaons. However, there is no guarantee that
interference will not occur in a parcular installaon. If this
equipment does cause harmful interference to radio or television
recepon, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for
help.
This equipment should be installed and operated with a
minimum distance 20cm between the radiator and your body.
This product and - if applicable - the supplied
accessories too are marked with "CE" and
comply therefore with the applicable harmo-
nized European standards listed under the RE
Direcve 2014/53/EU, the EMC Direcve
2014/30/EU, the RoHS Direcve 2011/65/EU.
2012/19/EU (WEEE direcve): Products
marked with this symbol cannot be disposed
of as unsorted municipal waste in the
European Union. For proper recycling, return
this product to your local supplier upon the
purchase of equivalent new equipment, or
dispose of it at designated collecon points.
For more informaon see: www.recycle-
this.info
FCC Conditions
This device complies with part 15 of the FCC Rules. Operaon is
subject to the following two condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operaon.
EU Conformity Statement
2006/66/EC (baery direcve): This product
contains a baery that cannot be disposed of
as unsorted municipal waste in the European
Union. See the product documentaon for
specific baery informaon. The baery is
marked with this symbol, which may include
leering to indicate cadmium (Cd), lead (Pb),
or mercury (Hg). For proper recycling, return
the baery to your supplier or to a designat-
ed collecon point. For more informaon see:
www.recyclethis.info
Use only power supplies listed in the user instrucons:
Model Manufacturer Standard
C2000IC12.0-24P-DE
C2000IC12.0-24P-GB
MOSO Power Supply
Technology Co., Ltd.
CEE
MOSO Power Supply
Technology Co., Ltd.
BS
The maximum power supply for the relay is DC 30 V, 2 A or AC 125 V, 0.5A.
Confirm with elevator manufacturers on wiring methods to avoid faults
caused by wrong wiring.
Andere Handbücher für DS-k2210
2
Dieses Handbuch passt für folgende Modelle
1
Andere HIK VISION Controller Handbücher

HIK VISION
HIK VISION DS-k2210 Bedienungsanleitung

HIK VISION
HIK VISION DS-K1T502 Series Bedienungsanleitung

HIK VISION
HIK VISION DS-C30S-S23 Bedienungsanleitung

HIK VISION
HIK VISION DS-K4H250 Series Bedienungsanleitung

HIK VISION
HIK VISION DS-K2M0016A Bedienungsanleitung

HIK VISION
HIK VISION DS-MDH005-B Bedienungsanleitung

HIK VISION
HIK VISION DS-K2M0016A Bedienungsanleitung

HIK VISION
HIK VISION DS-K4H250S Bedienungsanleitung

HIK VISION
HIK VISION DS-k2210 Bedienungsanleitung

HIK VISION
HIK VISION C30 Series Bedienungsanleitung