HKC APL-5 Series Gebrauchsanweisung

APL-5 Series Limit Switch Box
Installation Operation & Maintenance Manual
Doc No. : HUMG-APL5-16 Rev0 Page 1 / 13
APL-5 Series Valve Position Monitor
Installation, Operation & Maintenance Manual

APL-5 Series Limit Switch Box
Installation Operation & Maintenance Manual
Doc No. : HUMG-APL5-16 Rev0 Page 2 / 13
Contents
1. General ................................................................................................................. 3
2. Ordering Information ............................................................................................. 3
3. Standard specification ........................................................................................... 4
4. Preparing for Installation ....................................................................................... 4
4.1. Marking...................................................................................................... 4
4.2. Pre-Installation for use in potentially explosive atmosphere ........................ 5
4.3. Initial inspection ......................................................................................... 5
5. Standard Features ................................................................................................. 6
6. Installation ............................................................................................................ 6
6.1. Mounting bracket ....................................................................................... 6
6.2. Mounting limit switch box ........................................................................... 7
6.3. Cam setting ................................................................................................ 7
6.4. Wiring ........................................................................................................ 8
6.5. Setting for Position Transmitter Unit (APL- 5*6) ........................................ 10
7. Maintenance ....................................................................................................... 11
8. Inspection ........................................................................................................... 11
9. Storage ............................................................................................................... 12
10. Trouble shooting .............................................................................................. 12
11. Tools ................................................................................................................ 12
12. Installation and Maintenance Tips ..................................................................... 12

APL-5 Series Limit Switch Box
Installation Operation & Maintenance Manual
Doc No. : HUMG-APL5-16 Rev0 Page 3 / 13
1. General
1.1. HKC APL-5… series limit switch boxes are designed to provide accurate and reliable valve
position signalling and indicating of most valves or actuators manufactured.
1.2. APL-5… limit switch boxes consists of a visual position indicator, quick-set cam ass’y, terminal
strip, switch ass’y and easy mounting bracket. Quick-set cam allows for a quick and simple
hand operation in the setting of switches.
2. Ordering Information
APL - 5 1 0 N
① ② ③
① Enclosure type of explosion proof is based on IECEx :
Ex d IIC T6 Gb
Ex ia IIC T6 Gb (APL-520 * only)
Ex tb IIIC T85℃ Db, IP67
Enclosure type of explosion proof is based on ATEX :
II 2 G Ex d IIC T6 Gb
II 2 G Ex ia IIC T6 Gb (APL-520 * only)
II 2 D Ex tb IIIC T85℃ Db, IP67
Enclosure type of explosion proof is based on KCs, NEPSI :
Ex d IIC T6 Gb
Ex ia IIC T6 Gb (APL-520 * only, KCs only)
Ex tD A21 IP67 T85℃ (KCs only)
Enclosure type of explosion proof is based on CSA :
Class I, Division 1, Group B, C & D T6
Class I, Zone 1, AEx d IIC T6
Ex d IIC T6
② Switch type
10 : 2-SPDT (Wonwoo : SZM-V16-5FA-61)
11 : 3-SPDT (Wonwoo : SZM-V16-5FA-61)
12 : 4-SPDT (Wonwoo : SZM-V16-5FA-61)
13 : 2-SPST (Wonwoo : SZM-V16-5FA-61)
14 : 2-DPDT (Omron : DZ-10GW-1B)
15 : 2-SPDT + Potentiometer (Wonwoo : SZM-V16-5FA-61)
16 : 2-SPDT + Signal Unit(4~20mA) (Wonwoo : SZM-V16-5FA-61)
20 : Proximity Sensor (P&F : NJ2-V3-N)
21 : Proximity Sensor (Autonics : PS17-5DNU) (Except CSA)
23 : Proximity Sensor (P&F : NBB2-V3)
25 : Proximity Sensor (P&F : NJ2-V3-N) + Potentiometer
26 : Proximity Sensor (P&F : NJ2-V3-N) + Signal Unit(4~20mA)
30 : Reed type Proximity Sensor (MS-B 301)
③ Enclosure Material
N : Aluminium Alloy
S : Stainless Steel

APL-5 Series Limit Switch Box
Installation Operation & Maintenance Manual
Doc No. : HUMG-APL5-16 Rev0 Page 4 / 13
3. Standard specification
Model APL-5** *
Enclosure Rate Please refer to “2. Ordering Information, ① Enclosure type”
Enclosure Material High grade aluminium alloy or stainless steel
Ambient Temperature -20°C ≤ Ta ≤ +60 °C
Cable Entries Standard : Two NPT 3/4”, or M25 for Ex type
(Option for Non-Ex : NPT1/2”, PT3/4”, PT1./2”, PF3/4”, PF1/2”, M20)
Travel Angle 90 degree +/- 10%
Position Indicator Open : Yellow, Close : Red
Language : English (Option : French, German)
Mechanical Switch SZM-V16-5FA-61 (Wonwoo Starion)
16A 1/2HP 125/250Vac, 0.6A 125Vdc, 0.3A 250Vdc, 5A 125Vac
Proximity sensor NJ2-V3-N (PEPPERL+FUCHS) : 5~25Vdc , 15mA max.
PS17-5DNU(Autonics) : 12~24Vdc, 0.2mA max.
MS-B 301 : 250Vdc 3.0A max.
Potentiometer 1kΩ (Option : 0~5kΩ , 0~10kΩ)
Current Output Signal Unit 4~20mA, 20~4mA
Terminal Strip 8 point (option : 9~14P)
External Coating Thermally hardened polyester powder coating
4. Preparing for Installation
4.1. Marking
HKC logo / Trade mark
Model
Switches type
Cert No.
Applicable temp.
Serial No.
Manufactured year
Cable entry size
Warning letter
Maker address
Usage as Ex d & tb for APL-5***
Usage as Ex ia & tb for APL-520*
Usage as Ex d ia & tD for APL-5*** KCs

APL-5 Series Limit Switch Box
Installation Operation & Maintenance Manual
Doc No. : HUMG-APL5-16 Rev0 Page 5 / 13
4.2. Pre-Installation for use in potentially explosive atmosphere
Installation, commissioning, maintenance, repairs and modification work must only be
performed by qualified personnel with extensive knowledge on how to work on explosion-proof
electrical equipment.
Warning : Read this installation and maintenance manual carefully and completely before
attempting to install, operate, or troubleshoot the HKC product
4.2.1. Cable Connection
①Sealing devices must be used and shall be fitted directly at enclosure wall when using
conduit.
②Cable glands shall be suitable for the environment and shall be certified as flameproof if
used in Zone 1 application of IECEx scheme in order to connect outside electric wire.
③Cable glands and conduit to be installed minimum 8 full threads and the length of thread
is minimum 8mm.
④“Warning” : Please be sure that user should select the appropriate cable glands and
minimum 2SQ of wire for fear that the proper using temperature of cable entry and wire
way exceed 70 ℃ or the blanching point is over 80 ℃.
⑤When cable entries or conduit entries are not used, user or installer shall close by certified
blanking elements(stopping plugs) so that the flameproof properties of the enclosure are
maintained.
4.2.2. Groundings
①Always ground the enclosure in accordance with local electric codes. The most effective
enclosure grounding method is a direct connection to earth ground with minimal
impedance. Methods for grounding the enclosure include:
Internal ground connection : The internal ground is located inside the body .
External ground connection : The ground bracket is located on the side of body.
(Min 2SQ wire required)
4.2.3. Special Condition for safe use (“X” marking)
①Electrostatic discharge from window(over 1GΩ) may cause the ignition on the explosive
gas atmosphere. By adapting the conducting window bolts make reduce the risk from
electrostatic discharge.
②Before installation or maintenance products, shut off incoming power and grounding
should be connected.
③The window must only be cleaned with a damp cloth in order to avoid ignition hazard
caused by static electricity.
4.3. Initial inspection
When the user receipts the product, inspect the condition of the product and ensure the name
plate comparing with order sheet.
4.3.1. Remove packing wrap or wooden box carefully. Inspect the product for any physical
damage that may have occurred during shipment.
4.3.2. Check the product specification with product ordered. If an wrong product have been
shipped, immediately report to our coordinator.
Usage as Ex d for APL-5*** CSA

APL-5 Series Limit Switch Box
Installation Operation & Maintenance Manual
Doc No. : HUMG-APL5-16 Rev0 Page 6 / 13
5. Standard Features
No.
Part Name
Q’ty
Description
1
Window / Indicator
1
PC / ABS
2
Cover
1
Aluminium die casting (ADC12), Stainless steel (CF8M)
3
Captive Cover Bolt
4
Stainless steel
4
Name Plate
1
Stainless steel (A240 T304)
5
Shaft
1
Stainless steel (G4303 SUS303)
6
Cam
2
PC
7
Switch
2
Refer to the clause “2. Ordering Information ② Switch type”
8
Body
1
Aluminium die-casting(ADC12), Stainless steel(CF8M)
9
Terminal Strip
1
8P (9~14P available)
10
Earth Lug
2
Stainless steel
11
Blanking Element
2
Aluminium plug (ADC12)
6. Installation
6.1. Mounting bracket
Caution ; Where limit switch box or one of parts are to be moved, installed, disassembled,
reassembled by a hand, care must not be taken to cause injury by the harmful sharp edges
of corners or rough surfaces or residual electricity.
6.1.1. HKC shall supply a NAMUR VDI/VDE standards’ bracket and a fixing stuff for mounting on
actuator. Brackets are able to applied any type of valves ; manual valve, linear valve,
pneumatic rotary valve.
① Insure valve actuator alignment (fully open or closed).
② Place the mounting bracket on a horizontal plane of actuator
③ Tighten the bolts enclosed in a box using a proper tool.
4
3
2
1
5
6
7
8
9
10
11

APL-5 Series Limit Switch Box
Installation Operation & Maintenance Manual
Doc No. : HUMG-APL5-16 Rev0 Page 7 / 13
6.2. Mounting limit switch box
Caution ;
Do not attempt to work on limit switch box without first shutting off incoming power
6.2.1. Prior to mounting the limit switch box must be checked for any damage.
6.2.2. Damaged parts must be replaced by original spare parts.
6.2.3. Limit switch boxes are available with a NAMUR shaft that enables direct attachment to
actuator pinion without a coupler. These shafts feature a 4mm wide tang that engages the
4mm slot in NAMUR actuators.
①Check to be sure the drive slot on the top of the actuator
and the shaft of switch box are the same direction.
②Insert the shaft of switch box carefully into the
mounting bracket.
③Tighten the bolts enclosed in a box using a proper tool.
④Check the connection of shaft being assembled
correctly.
6.3. Cam setting
Note :
Basically, cams shall be set by manufacturer before shipment.
6.3.1. The colour of cams harmonized with position indicator help us to set the cams easily
without wiring diagram. Cams shall be easily set without tool. APL series cams are splined
and can be setting lift up or push down the cam from gear by hand in a seconds without
setting tools. Self-locking, spring loading make never slip out of adjustment.
6.3.2. Loose the captive cover bolts with an applicable tool. (L-Hex. Wrench recommended)
6.3.3. Turn the cover counter clockwise to open carefully.
6.3.4. Open cam setting
① Electric power or air supply of valve actuator on to operate the actuator fully open
② Lift the bottom yellow cam up and rotate it until the switch is activated.
③ And then release it. Cam shall be back into a stable position by itself.
6.3.5. Close cam setting
① Electric power or air supply of valve actuator off to operate the actuator fully close
② Push the upper cam down and rotate it until the switch is activated.
③ And then release it. Cam shall be back into a stable position by itself.
Mechanical switches
Proximity sensors
Splined cam

APL-5 Series Limit Switch Box
Installation Operation & Maintenance Manual
Doc No. : HUMG-APL5-16 Rev0 Page 8 / 13
6.4. Wiring
Danger ; HAZARDOUS VOLTAGE. No electrical power should be connected until all
wiring and limit switch adjustments have been completely.
6.4.1. [Open circuit before removing cover, and seal required within 50mm
(2 inch) of the enclosure by CSA ---- 15 r0]
6.4.2. APL limit switch box enclosure feature prewired switches. All user connections are made at
a numbered terminal strip. A wiring diagram, located inside the cover, indicates which
terminal numbers correspond to switch contacts, such as normally open (NO), normally
closed (NC), etc. Follow the wiring diagram and electrical code to connect the switches to
your system.
6.4.3. Solenoid valve may also can be wired through the APL enclosure. Two auxiliary terminals
are included as standard.
6.4.4. APL limit switch box has two cable entries on the body and supply a blanking plug not a
cable gland which meet the type of protection. Cable gland shall be applied by installer or
user.
①Mechanical Switch (2 SPDT)
②Mechanical Switch (3 SPDT)

APL-5 Series Limit Switch Box
Installation Operation & Maintenance Manual
Doc No. : HUMG-APL5-16 Rev0 Page 9 / 13
③ Mechanical Switch (4 SPDT)
④ Mechanical Switch (2 DPDT)
⑤ Mechanical Switch (2 SPDT) with Potentiometer

APL-5 Series Limit Switch Box
Installation Operation & Maintenance Manual
Doc No. : HUMG-APL5-16 Rev0 Page 10 / 13
⑥ Mechanical Switch (2 SPDT) with Signal Unit
Note ;
Grounding should be connected until all wiring had been completely.
Internal/External grounding wire square shall be min. 2SQ recommended.
6.5. Setting for Position Transmitter Unit (APL- 5*6)
6.5.1. Potentiometer reads the current position of actuator and transfers a resistance value to a
current position transmitter card. Transmitter indicates the actuator position throughout
the stroke by a 4~20mA output signal.
6.5.2. Technical Features
①Power Supply Range 12.5 ~ 37VDC (24V typical)
②Current Signal Output 4~20mA
③Max. Load Resistance Max. Resistance (ohm) = (Supply voltage 12.5) / 0.02
④Potentiometer 0~500 ohm / 10k ohm
⑤Operating Temperature -20 ~ 60 ℃
⑥Dimension 40 * 60 * 15
Dieses Handbuch passt für folgende Modelle
1
Inhaltsverzeichnis
Andere HKC Steuereinheit Handbücher
Beliebte Steuereinheit Handbücher anderer Marken

Festo
Festo Compact Performance CP-FB6-E Stücklistenhandbuch

Elo TouchSystems
Elo TouchSystems DMS-SA19P-EXTME Bedienungsanleitung

JS Automation
JS Automation MPC3034A Bedienungsanleitung

JAUDT
JAUDT SW GII 6406 Series Kurzanleitung

Spektrum
Spektrum Air Module System Bedienungsanleitung

BOC Edwards
BOC Edwards Q Series Bedienungsanleitung