HoMedics TE-200-EU Bedienungsanleitung

TE-200-EU
This equipment needs to
be installed and put into
service in accordance
with the information
provided in this manual 2 YEAR GUARANTEE

2 | GB
INTRODUCTION
Utilising infrared technology, this thermometer takes temperatures in seconds by
measuring heat generated by the surface skin of the forehead or other objects. This
product conforms to the provisions of the EC directive MDD(93/42/EEC). Its advantages
include:
1. 6 in 1 functions
Human Body/Object/Night Mode Option/Fever Alarm/30 User Memory/Backlight
2. Night Mode Option
Switch to Night mode to reduce the interference of buzzer during your baby
sleeping.
3. Red LED Light for Fever Alarm
This device has the LED light to remind user their readings are over 38°C and plus
the beep sound only in Human Body Mode.
4. 30 User Memory
5. Illuminated Backlight Display
6. C/°F Switch-able Function
7. One-second reading
8. Auto power o for power saving
9. Low-battery Indicator
10. Large LCD Display
11. Economic design and convenience:
This is a “Non-contact” medical thermometer that enables temperature readings,
designed for sanitary conditions, cleanliness, and convenience. Simply move the
thermometer close to the subject’s forehead or object at the distance indicated
by the device.
12. Instant Measurement
By using our unique technology, users can get their precise body temperature
instantly and accurate.
IMPORTANT INFORMATION BEFORE USE
When using this product, please be sure to follow all the notes listed below. Any action
against these notices may cause injury or aect the accuracy.

GB | 3
1. Do not disassemble, repair, or remodel the thermometer.
2. Be sure to clean the thermometer lens each time after usage.
3. Avoid direct finger contact with the lens.
4. No modification of this equipment is allowed.
5. It is recommended that user may take 3 temperatures. If they are dierent, use
the highest reading.
6. Do not expose the thermometer to extreme temperature, very high humidity,or
direct sunlight.
7. Avoid extreme shock or dropping the device.
8. Before the measurement, users and thermometer should stay in steady state room
condition for at least 30 minutes.
9. Avoid measuring temperature for 30 minutes after exercise, bathing, or returning
from outdoors.
10. To protect the environment, dispose of empty batteries at appropriate collection
sites according to national or local regulations.
11. It is ill-advised to disassemble the thermometer.
12. Please use the thermometer solely for its intended purpose.
13. Carefully hold the device when in use to avoid dropping the device.
14. Allow one minute between successive measurements as slight variations may
occur if measurements are taken over a short period of time. Use average
temperatures instead.
15. There are no absolute body temperature standards. Keep reliable records of your
personal temperature to serve as a reference for judging a fever.
16. Under any circumstances, the temperature taking result is ONLY for reference.
Before taking any medical action,please consult your doctor.
BATTERY INSTALLATION
Low battery warning
When the battery power becomes low, the low battery symbol will appear on the
display. The thermometer can still be used during this time,but the batteries should
be replaced as soon as possible. If the batteries run out completely, “Lo” will
be displayed along with the low battery symbol. In this case, the batteries will need to
be replaced before using the thermometer again.

4 | GB
Replacing the Battery
1. Gently slide the battery cover back.
2. Carefully remove the old batteries and
properly discard.
3. Insert new batteries (Two 1.5Valkaline
AAA Size) according to the proper polarity.
4. Slide the battery cover back on.
Note
• It is recommended to remove the batteries
if the unit will not be used for an extended
period of time.
• Please store batteries away from small children and heat.
• Do not use rechargeable batteries.
• Dispose of used batteries in accordance with the applicable legal regulations.
• Never dispose of batteries in the normal household waste.
PRODUCT IDENTIFICATION
Memory
Recall
button
Battery
compartment
lid
LCD display
Power /
scan & measure
Button
Human/Object
Button
Red LED Light
for Fever Alarm
(Only in Human
Mode)
Measurement sensor
Buzzer

GB | 5
DESCRIPTION OF LCD DISPLAY
SWITCHING BETWEEN CELCIUS OR FAHRENHEIT
Your thermometer can display results in either degrees Celsius (°C) or
degrees Fahrenheit (°F).
To switch between Celsius and Fahrenheit, while the unit is on press
and hold both the Human/Object button and the Memory button for
approximately 3 seconds. This will change the mode to either °C or °F.
Once the thermometer beeps, at which time the mode
has been changed and you may release the buttons.
Switching between 4 Kinds of Scan Mode
1. Under power on status, you can press the Human/Object button
to switch dierent scan mode.There are 4 kinds of mode which including Human,
Object, Human/Night, and Object/Night mode (in order).
2. The beep sounds will be closed when your choice in Human/Night mode, and
Object/Night mode, and the Moon symbol will appears on the LCD in both Night
mode.
Temperature in degrees
Celcius scale
Fahrenheit scale
Scan in progress
Frowning face
Measurement
≥38.0°C(≥ 100.4°F)
Fever
Smiling face
Measurement
<38.0°C(< 100.4°F)
No Fever
Low battery warning
Memory symbol
and sets of
records
Night mode Human scan mode
Object scan mode

6 | GB
Human mode Object mode Human mode
& night mode
Object mode
& night mode
Note
Each press will comes with a beep sound to ensure the setting is activated. (Except both
Night modes)
TIPS FOR MEASURING HUMAN TEMPERATURE
Bear in mind that the thermometer needs to have been in the room in which the
measurement is taken for at least 30 minutes before use.
• Attempting to take temperature readings from sites on the body other than the
forehead may produce inaccurate results.
• The patient should remain still while the reading is being taken.
• Infrared forehead temperature readings are equivalent to oral temperature readings.
In all of these cases, please consult your doctor.
• Readings taken while asleep should not be compared directly to readings taken while
awake, as body temperature while asleep is typically lower.
• Do not take body temperature readings within 30 minutes of being outdoors,
exercising or bathing.
MEASURING HUMAN TEMPERATURE
1. Press the Power button to turn the thermometer on. The unit will
run a self-test and all symbols on the display will momentarily
appear.
2. Ensure that the thermometer is in Human mode; the Human
symbol will be on the display. To alternate between modes press
and release the Human/Object Mode button until you see the
desired measurement symbol on the display.
3. Press and hold the “Scan & measure button”, aiming the

GB | 7
Measurement Sensor at the person’s
forehead, holding the thermometer
approximately 0.5~3 cm. But don’t touch
the forehead.
4. Release the “Scan & measure button”.
In about a second, you will hear a short beep means this temperature reading has
been completed and accompany with a back-light.
5. If the temperature measurement is below 38°C, a “Smiling Face” will be
appear next to the reading. If the reading is 38°C or above, a “Frowning Face”
will be displayed and the RED LED light up.
Fever Alarm - Only in Human Mode and Human/Night Mode
6. After about 30 seconds after use, the thermometer will automatically beep and
shut o.
MEASURING OBJECT TEMPERATURE
1. Press the Power button to turn the thermometer on.
All symbols on the display will momentarily appear.
2. Ensure that the thermometer is in Object mode; the
Object symbol will be on the display. To alternate
between modes press and release the Human/
Object Mode button until you see the desired
measurement symbol on the display.
3. Press and hold the “Scan & measure button”,
aiming the Measurement Sensor at the object,
holding the thermometer approximately
0.5~3 cm.
4. Release the “Scan & measure button” and the
temperature reading will be displayed.
5. After about 30 seconds after use, the thermometer will automatically beep and
shut o.
MEMORY FUNCTION
You can recall up to 30 stored measurements in memory to share with your doctor or
trained healthcare professional.
0.5 ~3 cm
0. 5~3 c m

8 | GB
Memory Recall button.
1. When the device is on, press once briefly on the “MEM button”, then pass it again
to show the last measurement accompanied by symbol.
2. The symbol or symbol will appear with each measurement stored in
memory to indicate whether a person or object temperature was taken.
3. Each press of the same button recalls a previous measurement, so then all
the way to . Continue to press the Memory Recall button button to view the
next previously stored measurement.
4. Any new measurement will be recorded and the oldest memory deleted without
you having to do anything.
Memory Deletion
1. Under power on status, you may keep press MEM Button for more than 3 seconds
to delete all the readings.
2. You will see “--” on display and “sound four short beeps”, that mean all the
memories are cleared.
3. Automatically on the 31th measurement: when the 30 memories have been used
up, any new measurement will be recorded with and the oldest memory
deleted without you having to do anything.
All the readings will be cleared no matter record in Human mode or Object mode.
CLEANING AND DISINFECTING
Lens/ Measurement Sensor
Gently clean with an alcohol swab.
Do not use water to wash the thermometer lens directly.
Thermometer
Clean with a soft, dry cloth.
Do not use water to rinse the device.

GB | 9
APPLIED STANDARDS
This product conforms to the provisions of the EC directive MDD(93/ 42/ EEC).The
following standards apply to design and/or manufacture of the products:
• ASTM E1965-98
Standard Specification for Infrared Thermometers for Intermittent Determination of
Patient Temperature.
• ISO 14971
Medical devices-Application of risk management to medical devices.The
Classification according to IEC/EN60601-1 sub-clauses 5:
ERROR CODES
When a malfunction or incorrect temperature measurement occurs, an error message will
appear as described below.
LCD Display Cause Solution
The temperature measured
is higher than
Human thermometer mode:
43°C (109.4°F)
Object temperature mode:
100°C (212.0°F)
Operate the thermometer only
between the specified temperature
ranges. If necessary, clean the
sensor tip. In the event of a
repeated error message,contact
your retailer or Customer Services.
The temperature measured
is lower than
Human thermometer mode:
34°C (93.2°F)
Object temperature mode:
0°C (32.0°F)
The operating temperature is
not in the range 16°C~40°C
(60.8°F~104°F)
Operate the thermometer only
between the specified temperature
ranges.

10 | GB
TECHNICAL SPECIFICATION
• Measuring range:
Human Body: 34°C ~43°C (93.2°F ~ 109.4°F)
Object: 0°C~100°C (32.0°F~212.0°F)
• Calibration Accuracy:
Human Body:
±0.2°C(±0.4°F): from 34°C ~43°C (93.2°F ~ 109.4°F)
Object:
<LESS THAN EQUAL TO>40°C : ± 2°C
> 40°C : ± 5%
• Power supply: 2 x 1.5VAAA size alkaline batteries
• Dimensions: approx. 128.5mm×48.83mm×38.85mm (L×W×H)
• Weight : approx. 80g (with batteries)
• Operation Distance : 0.5~3 cm
EXPLANATION OF SYMBOLS
SGS No.
Refer to instructions
Type BF equipment (Sensor)
Disposal information: Should you wish to dispose of the article, do so in accordance
with current regulations.Details are available from your local authority
Manufacturer’s name and address
European Authorized Representative
Inhaltsverzeichnis
Sprachen:
Andere HoMedics Thermometer Handbücher

HoMedics
HoMedics HTD8816C Bedienungsanleitung

HoMedics
HoMedics THERA-P TE-120 Bedienungsanleitung

HoMedics
HoMedics NO TOUCH Bedienungsanleitung

HoMedics
HoMedics PG-IRT1603 Bedienungsanleitung

HoMedics
HoMedics TIE-210 Bedienungsanleitung

HoMedics
HoMedics TE-101-EU Bedienungsanleitung

HoMedics
HoMedics HTD8216C Bedienungsanleitung

HoMedics
HoMedics TT-200 Bedienungsanleitung

HoMedics
HoMedics TO-R100-0GB Bedienungsanleitung

HoMedics
HoMedics TE-101 Bedienungsanleitung