howen Hero-TD01-G Bedienungsanleitung

1
Howen AI Thermodetector
User Manual
Model :Hero-TD01-G

2
CONTENTS
1. PRODUCT OVERVIEW.............................................................................................................................3
1.1 PRODUCT INTRODUCTION............................................................................................................................. 3
1.2 PRODUCT FUNCTIONS.................................................................................................................................. 3
2. WIRING INSTRUCTIONS..........................................................................................................................3
2.1 WIRING INSTRUCTIONS................................................................................................................................. 4
2.2 CONNECT THE DEVICE TO PC....................................................................................................................... 5
2.3 CONNECT THE LOCK OF DOOR (PUSH_OUT)............................................................................................... 6
2.4 WIRING INSTRUCTIONS(LOCK_NONC_12V )..................................................................................... 6
3. CLIENT OPERATIONS..............................................................................................................................7
3.1 DEVICE MANAGEMENT ................................................................................................................................. 8
3.1.1 Adding Device..................................................................................................................................... 8
3.1.2 Device Settings................................................................................................................................... 9
3.2 STAFF MANAGEMENT.................................................................................................................................. 15
3.2.1 Adding Staff....................................................................................................................................... 15
3.2.2 Batch-adding From file..................................................................................................................... 16
3.2.3 Edit Users.......................................................................................................................................... 16
3.2.4 Delete................................................................................................................................................. 17
3.2.5 Staff Sync .......................................................................................................................................... 18
3.2.6 Clearing Device users...................................................................................................................... 20
3.2.7 Blacklist and White-list..................................................................................................................... 21
3.2.8 Device Access Control Parameters............................................................................................... 22
3.2.9 User Access Information ................................................................................................................. 23
3.3 VOICE OF NOTIFICATION ............................................................................................................................. 23
4. DATA QUERY...........................................................................................................................................24
4.1 UPDATING ATTENDANCE RECORDS............................................................................................................ 24
4.2 EXPORT ATTENDANCE RECORD................................................................................................................. 24
5. FAQ ...........................................................................................................................................................25

3
1. Product Overview
1.1 Product Introduction
HowenAI Thermodetector Hero-TD01-G adopts the new AI chip-set, large thermal sensor array,
and latest algorithm, providing the cutting-edge face recognition and body temperature detection,
with ability to detect wearing the mask. Hero-TD01-G can identify human forehead automatically
from 0.3meter ~1.2meter to get ±0.2℃high accuracy body temperature within 0.05second.
1.2 Product Functions
⚫Proximity wake-up activation: the device is automatically activated when a person
approaches.
⚫7-inch touch screen: displays the software interface, operation guidance and face frame.
Performs real-time face detection (supports local video preview).
⚫2 million pixel binocular wide angle camera.
⚫Anti-fake function for pictures and videos.
⚫Facial recognition distance of up to 1 meter, for a height range of 1.4m to 1.9m.
⚫Use of deep learning algorithms to support a capacity of 10,000 faces. Fast recognition
with a higher recognition rate.
⚫Storage of up to 30,000 events.
⚫Multiple authentication methods.
⚫Facial comparison time ≤ 0.05s/person. Recognition rate ≥99.9%.
⚫Support for importing of card and facial data to devices through TCP/IP transmission or
USB interfaces.
⚫Uploading of data through the internet.
⚫Uploading of comparison results and interconnected snapshots to the platform for
storage.
⚫Personnel information can be sent down from the platform or uploaded from local
devices.
⚫Stand-alone operation in offline mode.
⚫Local login for managing, searching and configuring device parameters.
2. Wiring instructions
Face recognition terminal can be docked through the tail line access control locking, in the
retention of existing access control system function of the colleague, the access control intelligent
operation upgrade. It is possible to simulate the opening of the door with the PUSHOUT signal and
directly drive the electromagnetic anode or cathode locks with the LOCKNONC signal.
For direct drive of Anodic or cathodic locks, a 12V/2A switched power supply is recommended for
panel machine input.
Note the following when wiring.

4
⚫If 1.0mm national standard wire is used, 12V switching power supply is used, and the wiring
distance from the site construction (switching power to equipment distance) does not exceed
20m.
⚫If 1.5mm national standard cable is used, 12V switching power supply is used, and the wiring
distance from the site construction (switching power to equipment distance) does not exceed
30m.
⚫If 2.0mm national standard wire is used, 12V switching power supply is used, and the wiring
distance (switching power to the equipment distance) is not more than 40m.
2.1 Wiring instructions
The wiring instructions are shown in the table below.
Wire Description
Function
Wire
sequence
Name
Description
A DC IN
POWER
1
12V in
12V power supply, 2A
2
GND
Ground
B Type-A USB
USB Host
1
5V
Only used for factory testing.Do
Not connect it.
2
DN
3
DP
4
GND
C RJ45
Ethernet
1
Ethernet
Standard 100 megabit network
port, connect to PC for
configuration.
D OUT-4pin
lock control
signal
1
PUSH_OUT
Switching Level Output
2
LOCK_NONC_1
12V switching drive output

5
2V
3
GND
Ground
4
12V out
12V power output
E 2 pin
Reserved
1
N/A
2
Precautions:
1). Line group 4, pin 4 (12V out), current limit output 1A, load beyond power, will cause panel
machine hardware damage.
2). Wire group 4, pin 2 (LOCK_NONC_12V), current limit output 800mA, beyond the power of the
latch access, will cause panel machine hardware damage.
3). Wire group 4, pin 2 (LOCK_NONC_12V) and pin 3 (GND), please do not short-circuit,
otherwise it will cause hardware damage to the panel machine.
4). Wire group 4, pin 1 (PUSHOUT) and pin 4 (12V out), please do not short-circuit, otherwise it
will cause hardware damage to the terminal.
2.2 Connect the device to PC
1.Connect the network cable via RJ45 to your PC directly or via router.
2.The default IP address of device is 192.168.1.100, so need make sure your PC in the same IP
address segment (192.168.1.***). Or you can add the 192.168.1.** IP segment in Advanced.

6
3. Turn off firewall of your PC.
2.3 Connect the Lock of door (Push_out)
A. Conventional access control system, generally with a button to open the door function, it is
recommended that the terminal PUSHOUT terminal directly and connected to the open the door
button wiring, in line with the permission to open the door action through PUSHOUT directly
simulate the button grounding operation, does not affect the original door button function.
2.4 Wiring instructions(LOCK_NONC_12V )
The hardware wiring is as follows, the switching quantity signal can be directly output 12V, no
external power supply is required to power the lock.
Note: The original door controls cannot be unlocked when the power is removed.

7
Anode Lock
Software Configuration: In the ARFaceManager tool, go to the Personnel Permissions page (3.2.8
Device Access Control) and set the door magnet type to "Normally Closed".
Cathode Lock
Software Configuration: In the ARFaceManager tool, go to the Personnel Permissions page (3.2.8
Device Access Control) and set the door magnet type to "Normally Open".
3. Client operations
You can set up and operate your device through client ARFaceManager.exe. This chapter
introduces the functions and operating procedures of access control.
The main interface contains System menu, 4-channel preview interface, identified staff
info( temperature, mask, name) and Un-identified person info (temperature, wear mask or not).

8
Video Preview: You can get the live streaming info;
Device Manage: Search, edit and set the device.
Staff Manage:Add/edit/delete the staff personal info, and authorize the door-Lock function.
Data Query: Export the attendance of registered staff.
3.1 Device Management
3.1.1 Adding Device

9
1) On the left side of the control panel, click Device Management -> Search Device
2) Click Device Management -> Add Device
Select the camera you want to add, fill in the device name (required) and position (required), and
click “Add select”. You can also delete it via “Delete”.
3.1.2 Device Settings
Device settings includes device parameters, upload settings, algorithm configurations, display
configurations, and video settings.

10
3.1.2.1 Device parameters
⚫Internet settings
Static IP settings:
1. Uncheck “Enable DHCP”. Check “Directly”.
2. Configure unified IP address, you can change the IP address. Click “ Reboot after
setting” .The default one is 192.168.1.100.
3. Click “Set up”. The parameters will be synchronized to the device.
⚫NTP settings:
1. Configure the NTP server IP address, port number, update cycle and time zone.
Inhaltsverzeichnis