Hoymiles DTU-W100 Bedienungsanleitung

Data Transfer Unit
DTU-W100
User Manual
REV1.0 All rights reserved

2
Corporate Headquarters Contact Information
Hoymiles Converter Technology Co.,Ltd.
No.18 Kangjing Road,
Hangzhou 310015,
China
www.hoymiles.com
Copyright Hoymiles Converter Technology Co., Ltd. All rights reserved

3
Table of Contents:
1.Important Safety Information .......................................................................................................... 4
Foreword ........................................................................................................................................ 4
Safety Instructions ........................................................................................................................ 4
2.The monitoring system of Hoymiles.................................................................................................... 5
3. DTU Installation Operation ............................................................................................................ 6
3.1 Install The DTU ...................................................................................................................... 6
3.2 WIFI Configuration Process ................................................................................................. 7
3.3 Boot Process .......................................................................................................................... 9
3.4 Indicator Light Status Description ....................................................................................... 9
4.Improve Installation Maps And Record Archives ....................................................................... 10
5.Server side browsing ..................................................................................................................... 11
6.Mobile APP view power station information ............................................................................... 12
7.Specifications.................................................................................................................................. 14

4
1.Important Safety Information
Foreword
This manual contains important instructions to follow during installation and maintenance
of the Hoymiles Data Transfer Unit(DTU)
Safety Instructions
·Only qualified personnel can install or replace the DTU.
·Do not attempt to repair the DTU as it contains the parts that are not serviceable to users. If
the DTU breaks down, please contact your distributor for maintenance. Opening the DTU
without permission will invalidate the warranty.
· Please read all technical instructions and cautions in this manual and on the DTU
before
installing and using DTU.
Audience
This manual is only for professional installation and maintenance personnel to use.
Symbols replace words on the equipment, on a display, or in manuals.
Symbols Expl n tion
DC volt ge
RECYCLING
This product be rs the selective sorting symbol for W ste electric l nd
electronic equipment (WEEE). This me ns th t this product must be h ndled
pursu nt to Europe n directive 2012/19/EU in order to be recycled or dism ntled
to minimize its imp ct on the environment.
User h s the choice to give his product to competent recycling org niz tion or
to the ret iler when he buys new electric l or electronic equipment.
Use only power supplies listed in the user instructions
Trademark

5
2.The monitoring system of Hoymiles
The DTU is the key component in Hoymiles monitoring system.
It is the relay station of
the monitoring system, which operates between the Hoymiles microinverters and the
Hoymiles Monitoring Server.
The DTU communicates with the microinverters in the system
via 2.4G RF wireless to collect the data and status of the microinverters in the system.
At the
same time, DTU connects to the Internet through WIFI,which realizes the information
exchange with the Hoymiles cloud monitoring service platform and sends all the running
data of microinverters and status of the system to the Hoymiles cloud monitoring server. It
receives the control commands from the cloud monitoring server and sends the data to the
microinverters in the system to achieve remote operation and maintenance.

6
Other Elements in the Hoymiles Microinverter System
The Microinverter: It converts the DC output of solar modules into grid-compliant AC power.
It sends the output electrical information of PV panels and the operation data of the
microinverters to the DTU, which is the hardware basis of the panel-level monitoring. With
efficiency up to 96.7% and MPPT efficiency up to 99.9%, Hoymiles microinverters rank in the
first level around the world in 2015.
The Hoymiles Monitoring Server: It collects the operation data and status of the
microinverters in the system, and provides the panel-level monitoring for the users and
maintenance staffs
t
o achieve remote operation and maintenance, which can improve
operational and maintenance efficiency.
3. DTU Installation Operation
3.1 Install The DTU
1.Plug the DTU connection adapter into the wall socket (the wall socket should be more than
1 meter above the ground).

7
2.Or plug the DTU into the power adapter and plug it into the cable outlet. Place the socket
on the table (when the table is placed, the table surface should be more than 1 meter
above the ground).
Note: The table should not be metal or concrete structure (to prevent the effects on 2.4G RF
signal).
3.The DTU is placed as far as 90 degrees vertically upwards.
4.The distance between the DTU and the router should be as close as possible.
3.2 WIFI Configuration Process
Connect the wireless name of DTUW- via computer or mobile phone, and then open the
browser and enter 10.10.100.254 to open the wifi configuration page. The username and
password are ‘admin’ by default. After entering, click the wifi parameter menu on the left
menu bar to enter the wifi parameter configuration. Then click the search button in the lower
right corner, select the wifi name to be connected to the DTU and enter the password, then
click Save and click Restart next.
Note: Non-professionals should not modify other parameters.

8

9
3.3 Boot Process
When the DTU starts to work, the red, green and blue lights are on for one second, then
the red light is on. The green light flashes to indicate that the search is slightly reversed and
connected to WIFI. The red and green lights flash alternately to indicate that the server is
connected and the WIFI is searched. After the search, the green light stops flashing and
turns solid.
3.4 Indicator Light Status Description
LED
light
DTU
status Red Blue Green
Red
+Blue+Grean
1 Power-on
Alternate Bright
(1s)
2 Upgrade procedure
Alternate Shining
(1/3s)
3 normal operation
Bright
4 ID search is not complete Shining
5 Not ID Bright
6
Not connected to WIFI
Bright
7
Server not connected
Shining
8
Receive server data
Shining

10
4.Improve Installation Maps And Record
Archives
1.Check if the indicator light is normal.
2.Confirm whether the connection is successful.
3. Please improve the installation map.
4.Remove the DTU serial number and attach it to the blank field of the DTU serial number on
the installation map.
5. record archive
User address DTU Roof type capacity Installation