HPE PSR3000-54A Bedienungsanleitung

HPE PSR3000-54A
Power Supply User Guide
Part number: 5200-2110
Document version: APW100-20160812
5200-2110

© Copyright 2016 Hewlett Packard Enterprise Development LP
The information contained herein is subject to change without notice.
The only warranties for Hewlett Packard Enterprise products and
services are set forth in the express warranty statements
accompanying such products and services. Nothing herein should be
construed as constituting an additional warranty. Hewlett Packard
Enterprise shall not be liable for technical or editorial errors or
omissions contained herein.
Confidential computer software. Valid license from Hewlett Packard
Enterprise required for possession, use, or copying. Consistent with
FAR 12.211 and 12.212, Commercial Computer Software, Computer
Software Documentation, and Technical Data for Commercial Items
are licensed to the U.S. Government under vendor’s standard
commercial license.
Links to third-party websites take you outside the Hewlett Packard
Enterprise website. Hewlett Packard Enterprise has no control over
and is not responsible for information outside the Hewlett Packard
Enterprise website.
Acknowledgments
Intel®, Itanium®, Pentium®, Intel Inside®, and the Intel Inside logo
are trademarks of Intel Corporation in the United States and other
countries.
Microsoft® and Windows® are trademarks of the Microsoft group of
companies.
Adobe® and Acrobat® are trademarks of Adobe Systems
Incorporated.
Java and Oracle are registered trademarks of Oracle and/or its
affiliates.
UNIX® is a registered trademark of The Open Group.

i
Contents
Overview····························································1
Front panel ················································································· 2
LEDs··························································································· 2
Technical specifications······························································ 3
Power supplies configuration······················································ 4
Installing and removing the power supply··········6
Installing the power supply························································· 6
Installing the power supply···················································· 6
Connecting the power cord ··················································· 8
Removing the power supply····················································· 10
Removing the power cord ··················································· 11
Removing the power supply················································ 11
Document conventions and icons ····················13
Conventions·············································································· 13
Network topology icons ···························································· 15
Support and other resources····························17
Accessing Hewlett Packard Enterprise Support······················· 17
Accessing updates ··································································· 17
Websites·············································································· 18
Customer self repair···························································· 19
Remote support··································································· 20
Documentation feedback····················································· 20

1
Overview
The PSR3000-54A (JH348A) AC-input and DC-output power supply
is hot swappable and provides a maximum output of 3000 W.
Table 1 PSR3000-54A power supply features
Feature Description
Protection
Protection against input under-voltage, input
over-voltage, output over-voltage, output short
circuit, output under-current, output over-current,
and overheat.
Redundancy The power supplies can operate in N+1 or N+N
redundancy. For more information, see "Power
supplies configuration."
Hot
swapping You can install or remove the power supply when
the device is operating.
The power supply shuts down automatically when its temperature
exceeds the acceptable range. When the temperature returns to the
acceptable range, the power supply automatically restarts.

2
Front panel
Figure 1 Front panel
(1) Power input LED (AC OK) (2) Handle
(3) AC input receptacle (4) Latch
(5) Power output LED (DC OK) (6) Air vents
LEDs
The PSR3000-54A power supply has two LEDs.

3
Table 2 LED description
LED Mark Color Description
Power
input
LED
AC
OK Off
No AC power input.
Low AC input voltage. The power
supply has entered the protected
state.
Green Normal AC input.
Power
output
LED
DC
OK
Green Normal DC output.
Red
DC output failure. An alarm
condition occurs, for example,
output short circuit, output
over-current, output over-voltage,
output under-voltage, or remote
shutdown. The power supply has
entered the protected state.
Orange High temperature.
NOTE:
A
fte
r
the circuit breaker for the power supply is switched off, the
LEDs on the power supply will remain on for a while.
Technical specifications
Table 3 Technical specifications
Item Specifications
Rated input voltage 100 to 240 VAC @ 50 or 60 Hz
Rated output voltage 54 VDC

4
Item Specifications
Maximum input current 16 A
Maximum output
current 55.6 A
Maximum output power
•1200 W @ 110 VAC
•2400 W @ 175 to 200 VAC
•3000 W @ 220 VAC
Dimensions (H × W × D) 41 × 100 × 332 mm (1.61 × 3.94 ×
13.07 in)
Ambient
tempera
ture
Operating
temperature –10°C to +50°C (–14°F to +122°F)
Storage
temperature –40°C to + 70°C (–40°F to +158°F)
Power supplies configuration
Follow these guidelines to configure power supplies for the device:
•Determine the total number of power supplies based on the
actual power consumption, the power supply slot number, and
power redundancy design.
•Determine the power supply redundancy design based on the
power source conditions.
{When two mains power inputs are provided, you can
configure the power supplies in N+N redundancy. N+N must
be not greater than the total number of power supply slots.
{When one mains power input is provided, you can configure
the power supplies in N+1 or N+N redundancy. N+1 or N+N
must be not greater than the total number of power supply
slots.

5
•For easy usage and maintenance, configure a circuit breaker for
each power input. The rated current of the circuit breaker must
be a minimum of 20 A.

6
Installing and removing the power
supply
Installing the power supply
To avoid bodily injury and device damage, follow the procedures
in Figure 2 to install the power supply.
Figure 2 Power supply installation procedure
Before the installation, prepare an ESD wrist strap and a flat-blade
screwdriver yourself.
Installing the power supply
1. Wear an ESD wrist strap, and make sure the strap makes good
skin contact and is reliably grounded.

7
2. If the target slot has a blank panel, thread the flat-blade
screwdriver through the hole in the handle of the blank panel
and pull the blank panel out.
Figure 3 Removing the blank panel
3. Unpack the power supply.
4. Correctly orient the power supply.
If you install the power supply in a left power supply slot, make
sure the latch is above the handle. If you install the power supply
in a right power supply slot, make sure the latch is below the
handle.
5. Holding the handle of the power supply with one hand and
supporting the bottom of the power supply with the other, slide
the power supply along the guide rails into the slot until you hear
a click.